Majestic CVR36 Indoor Fireplace User Manual


 
11
STR/CVR Series Woodburning Fireplaces
7412961
Positioning, Safety Strips,
Securing the Fireplace
Slide fireplace into position.
Lift the fireplace front slightly and slide the metal safety
strips under front bottom edge about 1¹⁄₂" (38mm), al-
lowing the remainder to extend in front of firebox. Over-
lap strips at least 1/2" (13mm) to provide a positive joint.
(Flat safety strips are packed with fireplace.) (Fig. 13)
Safety strips are used to ensure that any combustible
materials in front of the fireplace are protected even
though a noncombustible hearth extension is required.
If fireplace is to be elevated above the floor, a “Z”
shaped metal safety strip must be fabricated and used
to protect combustible surfaces in front of the fireplace.
This “Z” shaped safety strip is not provided but must be
fabricated of metal with each horizontal leg at least 1¹⁄₂"
(38mm) wide and equal in length to the metals strips
provided with the fireplace.
NOTE: Safety strips are not required over non-com-
bustible floors where all supports at the base of the
fireplace are noncombustible.
Eight (8) nailing flanges are supplied with the fireplace
(found on the fireplace hearth). To level the box and
secure it firmly in place, remove the nailing flanges from
the hearth and install at the sides of the fireplace as
shown in Figure 14.
Outside Air Kit
An outside air kit damper is installed in all STR/CVR
Series Fireplaces. If desired, or if local codes mandate
the use of an air kit, then an AK-MST is required to
complete the installation (from air kit to the outdoors). If
the outside air kit is to be used, the AK-MST Air Ter-
mination Kit MUST be installed BEFORE the fireplace
is enclosed. Refer to the AK-MST instructions for field
installation. The outside air kit control is located in the
lower left hand side of the fireplace behind the screen
panel. (Fig. 15) To operate, simply lift up to close or
push down to open .
WF708
STR/CVR
5/29/98
Metal Safety
Strips
(1, 2 or 3 pieces)
" (13mm)
Min. Overlap

"
(38mm)
"Z"
Safety
Strip
Fire-
Place
Plat-
Form
Hearth Ext.
(not supplied)
FP708
Fig. 13 Safety strip installation.
FP709
Fig. 14 Fasten fireplace in position.
FP709
7/28/98
STR/CVR
Model STR
Standoffs
Side-Nailing
Flanges
Fig. 15 Outside air operation.
CLOSED
OPEN
WF 710
OUTSIDE AIR LEVER
WOOD FIREPLACES
5/28/98
FP710