Majestic Appliances 360DVS2 Indoor Fireplace User Manual


 
29
360DVS Series Direct Vent Fireplaces
10006326
Lighting and Operating Instructions
For Fireplaces equipped with SIT822 Gas Valve (EN or EP)
A. This fireplace is equipped with an ignition device
which automatically lights the pilot.
DO NOT try to
light the pilot by hand.
B. BEFORE OPERATING
, smell all around the
appliance area for gas. Be sure to smell next to
the floor because some gas is heavier than the air
and will settle on the floor.
What to do if you smell gas
Do not try to light any appliance
Do not operate any electrical switch.
Do not use any phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas suppliers
instructions.
For your safety, read the following warnings
before lighting the appliance:
1.
STOP! Read the safety information above before
continuing.
2. Turn off all electrical power to the appliance.
3. This appliance is equipped with an ignition device
which automatically lights the pilot. DO NOT try to
light the pilot by hand.
4. Access the gas control by lowering the lower
access door (louvre assembly).
If you cannot contact your gas supplier call
the Fire Department
C. Use only your hand to push in or turn the gas
control knob. Never use tools. If the knob will not
push in or turn by hand do not try to repair it, call
a qualified service technician. Force or attempting
repair may result in a fire or explosion.
D. Do not use this appliance if any part has been
under water. Immediately call a qualified service
technician to inspect the appliance and replace
any part of the control system and any gas control
that has been under water.
1. Turn the remote switch to the “OFF” position.
2. Turn OFF all electrical power to the fireplace if
service is required.
3. Open the lower access panel.
4. Turn the shutoff valve on the flexible gas line to the
“OFF” position.
Warning: If you do not follow these instructions exactly, a fire or explosion may result
causing property damage, personal injury and loss of life.
Lighting Instructions
Turning Off the Gas to the Appliance
HI
LO
5. Turn the remote switch, if used, OFF. Turn the
wireless remote, if used, OFF.
6. Wait five (5) minutes to clear out any gas. Then
smell for gas, including near the floor. If you smell
gas STOP. Follow instructions B in the safety
warnings above. If you do not smell gas go onto the
next step.
7. Close the access door.
8. Turn ON all electrical power to the appliance.
9. Turn remote switch or wireless remote to ON.
10. If the appliance will not operate, follow the
instructions “Turning Off the Gas to the Appliance”
(below), and call your service technician or gas
supplier.
FP297A
INSTA VENT FREE
UVHB26 GAS SUPPLY
7/1/98
NOTE: Shutoff valve
is shown in “ON” position
1/2” Gas Supply
1/2” NPT x 1/2” Flare
Shut-Off Valve
3/8” Flex Line
(from valve)