Mad Catz 5MPRA6E3-148 Water Pump User Manual


 
6
ELECTRICAL
Ground motor before connecting to electrical power supply. Failure to
ground motor can cause severe or fatal electrical shock hazard.
Do not ground to a gas supply line.
To avoid dangerous or fatal electrical shock, turn OFF power to motor
before working on electrical connections.
Ground Fault Circuit Interrupter (GFCI) tripping indicates an electrical
problem. If GFCI trips and will not reset, have a qualified electrician
inspect and repair electrical system.
Exactly match supply voltage to nameplate voltage. Incorrect voltage
can cause fire or seriously damage motor and voids warranty. If in
doubt consult a licensed electrician.
Voltage
Voltage at motor must be not more than 10% above or below motor name-
plate rated voltage or motor may overheat, causing overload tripping and re-
duced component life. If voltage is less than 90% or more than 110% of rated
voltage when motor is running at full load, consult power company.
Grounding/Bonding
Install, ground, bond and wire motor according to local or National Electrical
Code requirements.
Permanently ground motor. Use green ground terminal provided under motor
canopy or access plate (See Fig. 2); use size and type wire required by code.
Connect motor ground terminal to electrical service ground.
Bond motor to pool structure. Use a solid copper conductor, size No. 8 AWG
(8.4 sq.mm) or larger. Run wire from external bonding lug (see FIg. 2) to rein-
forcing rod or mesh.
Connect a No. 8 AWG (8.4 sq.mm) solid copper bonding wire to the pressure
wire connector provided on the motor housing and to all metal parts of the
swimming pool, spa, or hot tub and to all electrical equipment, metal piping
or conduit within 5 feet (1.5 m) of the inside walls of swimming pool, spa, or
hot tub.
Wiring
Pump must be permanently connected to circuit; be sure no other lights or ap-
pliances are on the same circuit. Match wire sizes to Table I (Pg. 5).
NOTICE: To prevent dirt, rain, bugs, etc., from entering motor when not
wiring with conduit, be sure to seal wire opening on end of motor.
Use Ground Fault Circuit Interrupter (GFCI) as master on-off switch; it will
sense a short circuit to ground and disconnect power before it becomes dan-
gerous to pool users. Test according to maker’s instructions.
In case of power outage, check GFCI for tripping (which will prevent normal
water circulation). Reset if necessary.
BONDING
LUG
GREEN
GROUND
SCREW
Hazardous voltage.
Can shock, burn,
or cause death.
Ground pump before
connecting to
power supply.
Figure 2 – Typical ground screw and
bonding lug locations.
Figure 3 – Wiring hook-up diagram
Single Phase
A
B
L2
L1
WHITE W/
BLACK TRACER
BLACK
115
VOLT
LINES
A
B
L2
L1
WHITE W/
BLACK TRACER
BLACK
230
VOLT
LINES