Lux Products T40-1143SA Thermostat User Manual


 
Place Base, Figure 3, over Sub-Base and attach by tightening three captive
screws.
Fasten loosely to wall using two mounting screws. Place a level against the
bottom of the Base, adjust until it is level and then tighten mounting screws to
secure.
Find anticipator setting on old thermostat. Setting on new thermostat should be
the same. Do this by carefully sliding the long pointer , Figure 2, over desired
number printed on the anticipator. If old anticipator setting cannot be
determined, look on gas control on furnace, or set at at .6. During heating
season, furnace should operate about five times an hour. If adjustments are
necessary, move heat anticipator pointer slightly and recheck. NOTE: Set
pointer to 1.2 for millivolt systems.
Attach front cover, Figure 1, to base.
Turn electricity and gas back on and set pointer on top of thermostat to desired
temperature.
FOR HEATING: Set slide switch to “Heat”. Set fan switch to “Auto”.
FOR COOLING: Set slide switch to “Cool”. Set fan switch to “Auto”.
FAN: For continuous blower operation, set switch to “ON”. For automatic
blower operation set fan switch to “Auto”. Thermostat will then cycle the blower
“on” and “off”.
A thermostat can only control temperature near it. If you find that it is
uncomfortable some distance away from the thermostat, change the
setting in order to compensate for this.
UP
.2
.25
.3
.4
.5
.15
.1
2
L
O
N
G
E
R
C
Y
C
L
E
S
HOLES FOR WIRES
MOUNTING HOLE
ANTICIP
LONG
POINTER
CAPTIVE
SCREW
CAPTIVE
SCREW
MOUNTING
HOLE
ATOR
FIGURE 1
FRONT COVER
FIGURE 2
BASE
These diagrams below are provided for new installations or
unreferenced wires.
NOTE
If you have an electric system and the blower does not operate after instal-
lation, find the factory installed yellow wire currently attached to the “Y” terminal
and move it to the “A” terminal on the sub-base.
TYPICAL SINGLE-STAGE
HEAT PUMP WIRING
Figure 12
110
GYWRHBORC
COMP
FAN
24 VAC HEAT
TRANSFORMER
CHG.
OVER
ADD
JUMPER
BETWEEN
Y & W
ALT.
110
TYPICAL COOLING AND
HEATING SYSTEM
(5-WIRE)
FAN
COOL
COMP
GAS
VALVE
24 VAC HEAT
TRANSFORMER
110
Figure 11
24 VAC COOL
TRANSFORMER
REMOVE
JUMPER
BETWEEN
RH & RC
GYWRH RCOB
TYPICAL COOLING AND
HEATING SYSTEM
(4-WIRE)
Figure 10
110
GAS
VALVE
COOL
COMP
FAN
24 VAC HEAT
TRANSFORMER
GYWRH RCOB
TYPICAL HOOKUP FOR 3-WIRE
HEAT SYSTEM IF THIRD
WIRE IS FAN WIRE
Figure 9
GAS
VALVE
110
FAN
24 VAC
TRANSFORMER
GYWRH RCOB
TYPICAL HOOKUP FOR 2-WIRE
24V HEATING SYSTEM AND
MILLIVOLT SYSTEM
Figure 8
GAS
VALVE
110
24 VAC
TRANSFORMER
OR
THERMOPILE
GYWRH RCOB
WARRANTY
TECHNICAL ASSISTANCE
Limited Warranty: If this unit fails because of defects in materials or
workmanship within three years of date of original purchase, LUX Products
Corporation will, at its option, repair or replace it. This warranty does not cover
damage by accident, misuse, or failure to follow installation instructions.
Implied warranties are limited in duration to three years from date of original
purchase. Some states do not allow limitations on how long an implied
warranty lasts, so the above limitation may not apply to you. Please return
malfunctioning or defective units to the participating retailer from which
purchase was made, along with proof of purchase. Please refer to
"TECHNICAL ASSISTANCE" before returning thermostat. Purchaser assumes
all risks and liability for incidental and consequential damage resulting from
installation and use of this unit. Some states do not allow the exclusion of
incidental or consequential damages, so the above exclusion may not apply to
you. This warranty gives you specific legal rights and you may also have other
rights which vary from state to state. Applicable in the U.S.A. only.
G
RC
RH
Y
W
UP
horiz
UP
vert
B
A
O
FIGURE 4
DECORATIVE WALL PLATE
FIGURE 3
SUB-BASE
This product does not contain mercury. However,
this product may replace a unit which contains
mercury and should not be disposed of in the trash.
Contact your local waste management authority for
proper disposal instructions for mercury in a sealed
glass tube. If you have any questions, please call
(856) 234-8803.
RECYCLING
NOTICE
If you have any problems installing or using this thermostat, please carefully
and thoroughly review the instruction manual. If you require assistance, please
contact our Technical Assistance Department at 856-234-8803 during regular
business hours between 8:00AM and 4:30PM Eastern Standard Time, Monday
through Friday. You can also receive technical assistance online anytime day or
night at http://www.luxproducts.com. Our web site offers you answers to the
most common technical questions, and also permits you to email your
questions to our technical support staff at your convenience.