LUX PRODUCTS CORPORATION
Mt. Laurel, New Jersey 08054 USA
IMPORTANT!
Thank you for your confidence in our product. To obtain the
best results from your investment, please read these
instructions and acquaint yourself with your purchase
before installing your new thermostat. Then follow the
installation procedures, one step at a time. This will save
you time and minimize the chance of damaging the
thermostat and the systems it controls. These instructions
may contain information beyond that required for your
particular installation. Please save for future reference.
READ
INSTALLATION
INSTRUCTIONS
FIRST
PSP711RF SERIES
SMART TEMP
®
ELECTRONIC THERMOSTAT
HEAT
OFF
COOL
AUTO
ON
FAN
RESET
HOLD
NEXT
RUN
FILTER
SET
SUNDAY
PROGRAM
SET
SATURDAY
PROGRAM
SET
WEEKDAY
PROGRAM
SET
DAY/TIME
DOWN
UP
1500
Patents Pending
M
O
D
A
Y
H
E
A
T
P
M
SIMPLIFIED INSTRUCTIONS
•Press UP/DOWN to set time.
TO SET PROGRAMS
•Rotate Dial to SET
WEEKDAY
TEMPORARY TEMPERATURE OVERRIDE
•Press UP/DOWN to adjust set temperature.
•To clear OVERRIDE press UP/DOWN until
original set temperature appears or wait for
thestart tf the next period
TO SET TIME & DAY
•Rotate Dial to SET
DAY/TIME.
•Press UP to change
td
HEAT
OFF
COOL
AUTO
ON
FAN
RESET
HOLD
NEXT
RUN
FILTER
SET
SUNDAY
PROGRAM
SET
SATURDAY
PROGRAM
SET
WEEKDAY
PROGRAM
SET
DAY/TIME
DOWN
UP
1500
Patents Pending
M
O
D
A
Y
H
E
A
T
P
M
SIMPLIFIED INSTRUCTIONS
•Press UP/DOWN to set time.
TO SET PROGRAMS
•Rotate Dial to SET
TEMPORARY TEMPERATURE OVERRIDE
•Press UP/DOWN to adjust set temperature.
•To clear OVERRIDE press UP/DOWN until
original set temperature appears or wait for
TO SET TIME & DAY
•Rotate Dial to SET
DAY/TIME.
•Press UP to change
DOWN
UP
M
O
D
A
Y
H
E
A
T
P
M
Choose Heat or CoolSet Day & TimeInstalls Easily
Easy
as
1–2–3
INSTALLATION AND OPERATING
INSTRUCTIONS
WARNING: Use Energizer
®
or DURACELL
®
Alkaline Batteries Only.
Energizer
®
is a registered trademark of Eveready Battery Company, Inc.
DURACELL
®
is a registered trademark of The Gillette Company, Inc.
• Press UP/DOWN
to set time.
TO SET TIME & DAY
• Rotate Dial to SET
DAY/TIME.
• Press UP to change
current day.
• Press NEXT.
TO SET PROGRAMS
• Rotate Dial to SET
WEEKDAY,
SATURDAY or
SUNDAY PROGRAM.
• Press UP/DOWN to adjust
start time.
• Press NEXT.
• Press UP/DOWN to adjust
temperature.
• Press NEXT.
• Repeat as needed or rotate
dial to RUN to stop Programming.
TEMPORARY TEMPERATURE OVERRIDE
•Press UP/DOWN to adjust set temperatur
PATENT NO. 5,673,850
e.
•To clear OVERRIDE press UP/DOWN until
original set temperature appears or wait for
the start tf the next period.
TEMPERATURE HOLD
• Press HOLD. Adjust temperature as
desired with UP/DOWN.
•To clear, press HOLD again.
SIMPLIFIED INSTRUCTIONS
The Active Program Period
Liquid Crystal
Display
Fan Switch
System
Switch
Easy to
follow
Instructions
LUX Speed
Dial
®
Thermostat
Body
The Set
Temperature
Thermostat
Cover
Button to Light
Display
FEATURES
52004
• The Unit can be used with most 24 volt gas, oil or electric heating and air
conditioning systems, single-stage heat pumps or gas millivolt heating
systems. It cannot be used with 120 volt heating systems or multistage heat
pumps. Ask your dealer for other LUX thermostats to control those systems.
•
The Unit is programmable.
There are four programming periods per day. Each
period can be programmed separately.
• You can use the built-in time/temperature programs, or alter them to suit
your schedule. The Unit provides separate programming for every day of the
week- for both heating and cooling. You can override the programmed tempera-
tures for as little as one programming period or for an entire vacation.
• In cool weather, when the system switch is set to HEAT, the Unit will maintain
cooler “set back” room temperatures to save energy. It will then change to
warmer “comfort” settings — all automatically, at specified times during the day.
• In warm weather, when the system switch is set to COOL, the Unit will maintain
warmer “set back” room temperatures to save energy. It will then change to
cooler “comfort” settings - all automatically, at specified times during the day.
• A large liquid crystal display shows time, day of the week, and room and set
temperatures. It will remind you when the filter should be changed in your blower
and track your system’s energy usage.
• Temperature swing adjustment lets you fine-tune your system for maximum
comfort and economy.
• A 4-minute minimum on/off time in COOL prevents your air conditioning
system from being damaged.
• Two Energizer® or DURACELL® “AA” alkaline batteries (not included) are
used to retain your time and temperature programs.
CAUTION
•Your thermostat is a precision instrument. Please handle it with care.
•Turn off electricity to the appliance before installing or servicing
thermostat or any part of the system. Do not turn electricity back on
until work is completed.
•Do not short (jumper) across electric terminals at control on furnace or
air conditioner to test the system. This will damage the thermostat and
void your warranty.
•All wiring must conform to local codes and ordinances.
•This thermostat is designed for use with 24 volt and millivolt systems.
The thermostat should be limited to a maximum of 1.0 amps; higher
amperage may cause damage to the thermostat. If you are in doubt,
call your utility company.
INSTALLATION
Please read all instructions carefully before beginning installation.
TOOLS REQUIRED
#1 Phillips screwdriver (small)
Drill with 3/16-in. (4.8mm) bit
THERMOSTAT LOCATION
On replacement installations,
mount the new thermostat in
place of the old one unless the
conditions listed below suggest
otherwise. On new installations,
follow the guidelines listed below.
1.Locate the thermostat on an
inside wall, about 5 ft. (1.5m)
above the floor, and in a room that is used often.
2.Do not install it where there are unusual heating conditions, such as: in direct
sunlight; near a lamp, radio, television, radiator, register, or fireplace; near
hot water pipes in a wall; near a stove on the other side of a wall.
3.Do not locate in unusual cooling conditions, such as: on a wall separating an
unheated room; or in a draft from a stairwell, door, or window.
4.Do not locate in a damp area. This can lead to corrosion that will shorten
thermostat life.
5.Do not locate where air circulation is poor, such as: in a corner or an alcove;
or behind an open door.
6.Do not install the unit until all construction work and painting has been
completed.
7.This thermostat does not require leveling.
CAUTION
To avoid electrical shock
and to prevent damage
to the furnace, air condi-
tioner, and thermostat,
disconnect the power
supply before beginning
work. This can be done at the
fuse box, at the circuit breaker, or
at the appliance.
OFF
© COPYRIGHT 2006 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED
1