Lux Products PSD111 Thermostat User Manual


 
1© COPYRIGHT 2004 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED
LUX PRODUCTS CORPORATION • Mt. Laurel, New Jersey 08054, USA 43367
IMPORTANT!
Please read all instructions carefully before
beginning installation and save for future reference.
Before removing any wiring from your existing thermostat, its wires
must be labeled with their terminal designations.
Ignore the color of the wires since they may not comply with any standard.
Thank you for your confidence in our product. To obtain the best results from
your investment, please read this manual and acquaint yourself with your
purchase before installing your new thermostat. Then follow the installation
procedures, one step at a time. This will save you time and minimize the chance
of damaging the thermostat and the systems it controls. These instructions may
contain information beyond that required for your particular installation. Please
save for future reference.
PSD111 SERIES
DIGITAL ELECTRONIC THERMOSTAT
HEAT
OFF
COOL
M
O
Set TemperatureChoose Heat or Cool
Installs Easily
Easy as
1–2–3
Complete, Easy To Read
INSTALLATION AND OPERATING INSTRUCTIONS
COMPATIBILITY
The unit can be used with
most 24 volt gas, oil or electric
heating and air conditioning
systems, gas millivolt heating
systems, and single stage heat
pumps. It cannot be used with
120 volt heating systems or
two stage heat pumps. Ask
your dealer for other LUX
thermostats to control those
systems.
FEATURES
Slim design may be vertically or
horizontally mounted
Large easy to read backlit display
Fan switch for system or continuous
fan operation
Simple temperature Up or Down keys
will display and adjust the Set Temperature.
Temperature displays in F° or C°
Temperature differential SWING settings of
0.25 and 0.5
Selectable 2 or 5-Minute Minimum
Run/Off time provides short cycle and
compressor protection
TEMP UP MODE
FAN
MODE
TEMP DOWN
BACKLIGHT
RESET
WARNING: Use Energizer
®
or DURACELL
®
Alkaline Batteries Only.
Energizer
®
is a registered trademark of Eveready Battery Company, Inc.
DURACELL
®
is a registered trademark of The Gillette Company, Inc.
In the winter, set the system switch to HEAT to control your heating system.
In the summer, set the switch to COOL to control your air conditioner.
Press either the TEMPERATURE UP or DOWN key in order to show the
current SET TEMPERATURE.
Press TEMPERATURE UP or DOWN keys again until your desired
temperature is displayed. The display will show the current room temperature
again after two seconds.
Press the light bulb button to illuminate the display. Adjusting the
temperature will keep the display lit until no button has been pressed for
over ten seconds.
In spring and fall or when windows are open, you can set the system
switch to OFF.
Setting the FAN switch to AUTO automatically runs your system’s fan during
heating and cooling.
Setting the FAN switch to ON runs your system’s fan continuously even
without heating or cooling.
NOTE
The FAN switch works only if your system provides a wire for the thermostat’s “G” terminal.
INSTALLATION
Please read all instructions carefully before beginning installation.
CAUTION
Turn off electricity to the appliance before installing or servicing
thermostat or any part of the system. Do not turn electricity back
on until work is completed.
Do not short (jumper) across electric terminals at control on furnace or air
conditioner to test the system. This will damage the thermostat and void
your warranty.
All wiring must conform to local codes and ordinances.
This thermostat is designed for use with 24 volt and millivolt systems.
The thermostat should be limited to a maximum of 1.5 amps; higher current
may cause damage to the thermostat. If you are in doubt, call your HVAC
contractor.
Your thermostat is a precision instrument. Please handle it with care.
O
FF
TOOLS REQUIRED
#0 Phillips screwdriver (small)
Drill with 3/16-in. (4.8mm) bit
Wire stripper/cutter
THERMOSTAT LOCATION
On replacement installations, mount the new thermostat in place of the old
one unless the conditions listed below suggest otherwise. On new installations,
follow the guidelines listed below.
Remember that your PSD111 may be mounted vertically or horizontally when
determining the optimal location.
Locate the thermostat on an inside wall, about 5 ft. (1.5m) above the floor,
and in a room that is used often.
Do not install it where there are unusual heating conditions, such as: in
direct sunlight; near a lamp, radio, television, radiator, register, or fireplace;
near hot water pipes in a wall; near a stove on the other side of a wall.
Do not locate in unusual cooling conditions, such as: on a wall separating an
unheated room; or in a draft from a stairwell, door, or window.
Do not locate in a damp area. This can lead to corrosion that will shorten
thermostat life.
Do not locate where air circulation is poor, such as: in a corner or an alcove;
or behind an open door.
Do not install the unit until all construction work and painting has been
completed.
OPERATING INSTRUCTIONS