Lux Products ELV1/PSPLV510 Thermostat User Manual


 
1© COPYRIGHT 2004 LUX PRODUCTS CORPORATION. ALL RIGHTS RESERVED
ELV1/PSPLV510
INSTALLATION INSTRUCTIONS FOR
For Use On:
Heating Only 120/240 Vac Single
Pole Applications
Baseboard, Ceiling Cable and
other Radiant Heat
Not For Use On:
Double Pole Applications
Heating/Cooling or Cooling Only
Low Voltage (24Vac) Systems
Electrical Rating
16A at 120/240 Vac
1900W at 120Vac
(Non-Inductive)
3800W at 240 Vac
(Non-Inductive)
Temperature Differential
±1°F Factory Preset; Adjustable
Batteries
Two Energizer
®
or DURACELL
®
“AA” alkaline batteries
(not included)
Programming
Preprogrammed - 4 Periods per
day
5 / 2 Programming
Weekdays/Weekends can be
different
°F / °C Changeable
Temporary Temperature Override
Vacation Hold
Dimensions
4.7” T x 2.7” W x 2.4” D
1.4” D from wall surface
Wall Plate
4.8” W x 5.0” H Wallplate
Included
Programmable Line Voltage Thermostat
LUX PRODUCTS CORPORATION • Mt. Laurel, New Jersey 08054, USA 43331-04
WARNING: Use Energizer
®
or DURACELL
®
Alkaline Batteries Only.
Energizer
®
is a registered trademark of Eveready Battery Company, Inc.
DURACELL
®
is a registered trademark of The Gillette Company, Inc.
WARNING
• This Thermostat is a line voltage (120 / 240 Vac) control. Do not
install it unless you are completely familiar with house wiring. If
improperly handled, there can be a risk of electric shock hazard
which may cause serious injury or death.
The thermostat is rated for normal full load current on a dual
residential 20A circuit breaker or fuse block. Do not use on circuits
protected by higher-rated over-current protection devices. Some
sustained fault conditions can cause product failure.
• Do NOT connect to voltage different from the device rating.
CAUTION
Disconnect power supply before making wire connections to
prevent electrical shock or equipment damage.
• All wiring must comply with applicable codes and ordinances.
Thermostats are designed to be used with appliances having a limit
control.
Maximum load for this thermostat MUST NOT EXCEED 3800W,
otherwise a potential fire hazard exists.
INSTALLATION
Location:
Install a vertical switch box for mounting the thermostat
approximately 1.5 m (5 ft.) above the floor on an inside wall where the
thermostat will be exposed to average room temperature. The
thermostat must be placed away from concealed warm or cold water
pipes, air ducts, or drafts from hallways, fireplaces or stairways to
sense temperature properly. Do not place the thermostat above the
heater.
WIRING
1. Disconnect power while installing. Double check that the
thermostat is rated for the voltage and amperage load to be
controlled.
2. Remove the cover by carefully pressing the button at the bottom of
the thermostat and swinging the body up and away.
3. When replacing an old line voltage wall thermostat, remove it
carefully to avoid damage to the insulation on the wiring. Check the
old insulation for cracks, nicks, or fraying and apply certified
electrical tape where necessary to achieve adequate insulation, or
replace the wires in an approved fashion.
4. Attach the wires with solderless wire connectors (provided). Be
sure that all wire connectors are tight.