Lopi Masonry Fireplace Factory Built (Metal) Fireplace Mobile Home Model: Pioneer Bay (Heritage Bay PI) Indoor Fireplace User Manual


 
Specifications 5
Travis Industries 4051216 93508051
Heating Specifications:
Approximate Maximum Heating Capacity (in square feet)* ........................................800 to 1,600 Sq. Feet
Burn Rate (Pounds per Hour)**............................................................................1.0 to 3.5
Maximum Burn Time on Low Burn** ......................................................................10 - 30 Hours
Hopper Capacity ..............................................................................................35 Pounds
* Heating capacity will vary depending on the home's floor plan, degree of insulation, and the outside
temperature. It is also affected by the fuel size, quality, and moisture level.
** Small pellets will increase or decrease the stated burn rates and burn times. Differences of plus or minus 20%
depending on fuel quality may occur.
Dimensions:
22"
28-7/8* for
8 x 10 Panels
31-7/8* for
10 x 13 Panels
40-1/2* for 8 x 10 Panels
44-1/2* for 10 x 13 Panels
* Includes trim and the required 3/8 gap between the surround panels and fireplace.
Center of 3 diameter Flue is 9-3/8 above
the baseplate and 5-1/8 left of center
9-1/2"*
11-5/8"*
19-5/8"
18-5/8"
22-1/8
Measure
clearances to
the hopper lid.
Electrical Specifications:
Electrical Rating.........................................................................................115 Volts, 3.6 Amps, 60 Hz
Watts During Start-Up Sequence...................................................................400 (approximately)
Watts During Operation ...............................................................................180 (approximately)
Fuel:
The unit is designed for wood pellets that comply with the standards set by the Association of Pellet Fuel
Industry (density of at least 40 lbs. per cubic foot, 1/4" to 5/16" diameter, length no greater than 11/2", 8200
BTU's/lb., moisture under 8% by weight, ash under 1% by weight, and salt under 300 parts per million). If the fuel
does not comply to this standard, the unit may not operate as designed.
EPA Compliance:
This heater is EPA exempt from Phase II requirements, but has been tested for emissions using EPA test
methods by OMNI Test Labs.