Lopi Leyden Wood Stove Stove User Manual


 
10 Stove Installation (for qualified installers only)
© Travis Industries 100-01177 4060802
Bypass Handle Installation
See Figure 4 for details on installing the bypass handle.
Line up the set screws on the bypass handle
with the dimples on the bypass shaft. Tighten
with the included 1/8” hex wrench.
1/8" Hex
Figure 4
Rear Vent Configuration
The rear vent configuration is only for masonry fireplace installations (hearth stove). All steel chimney
applications require the top vent configuration.
The vent (chimney connector) may be directed to the rear of the appliance when installed into a masonry
fireplace. See Figure 5 for details.
The flue collar is held in place with three bolts
and two nuts. Use two 7/16" open-end
wrenches to remove the bolts and nuts.
7/16" Wrench
NOTE: Make sure the gasket
underneath the flue collar is properly
located and seals the flue collar when
it is installed.
Open the bypass - this
allows for access to the
nut under the flue collar.
Remove the flue collar and rotate it to the rear.
Use the exi
sting bolts and nuts to attach the
sides of the flue. For the center connection
use the bolt and acorn nut included in the
owner's pack.
Figure 5