SPECIFICATION
Indoor unit model
MSZ-A09NA MSZ-A12NA
External nish
White
Power supply V, phase, Hz
208/230, 1, 60
Max.-fuse size (time delay) / Disconnect switch A
15
Min. circuit ampacity A
1.0
Fan motor F.L.A
0.76
Air ow
Low–Med.–High–Powerful
COOL Dry (Wet)
CFM
152-229-307-338
(134-205-275-303)
152-240-353-388
(134-215-318-349)
HEAT
159-222-307-321 159-240-353-353
Moisture removal pt./h
2.3 3.2
Sound level
Low–Med.–High–Powerful
COOL
dB(A)
22-33-38-41 22-34-42-44
HEAT
22-33-38-39 22-34-42-42
Cond. drain connection O.D. in.
5/8
Dimensions
W
in.
30-11/16
D
8-/1/4
H
11-/3/4
Weight Ib.
23
Remote controller
Wireless type
Control voltage (by built-in transformer)
12-24 VDC
Indoor unit model
MSZ-A15NA MSY-A15NA MSZ-A17NA MSY-A17NA
External nish
White
Power supply V, phase, Hz
208/230, 1, 60
Max.-fuse size (time delay) / Disconnect switch A
15
Min. circuit ampacity A
1.0
Fan motor F.L.A
0.76
Air ow
Low–Med.–High–Powerful
COOL Dry (Wet)
CFM
268-328-381-419 (240-293-342-376)
HEAT
254-314-381-381 — 254-314-381-381 —
Moisture removal pt./h
4.7 5.1
Sound level
Low–Med.–High–Powerful
COOL
dB(A)
34-40-45-47 34-40-46-48
HEAT
34-38-44-44 34-38-44-44
Cond. drain connection O.D. in.
5/8
Dimensions
W
in.
30-/11/16
D
8-/1/4
H
11-/3/4
Weight Ib.
23
Remote controller
Wireless type
Control voltage (by built-in transformer)
12-24 VDC
Indoor unit model
MSZ-A24NA MSY-A24NA
External nish
White
Power supply V, phase, Hz
208/230, 1, 60
Max.-fuse size (time delay) / Disconnect switch A
15
Min. circuit ampacity A
1.0
Fan motor F.L.A
0.76
Air ow
Low–Med.–High–Powerful
COOL Dry (Wet)
CFM
296-431-568-624 (265-385-508-558)
HEAT
296-486-568-590
Moisture removal pt./h
7.3
Sound level
Low–Med.–High–Powerful
COOL
dB(A)
34-40-49-51
HEAT
34-40-48-49
Cond. drain connection O.D. in.
5/8
Dimensions
W
in.
43-/5/16
D
10-/1/4
H
12-13/16
Weight Ib.
37
Remote controller
Wireless type
Control voltage (by built-in transformer)
12-24 VDC
NOTE : Test conditions are based on ARI 210/240.
1 : Rating conditions (Cooling) — Indoor : 80˚FDB, 67˚FWB, Outdoor : 95˚FDB, (75˚FWB)
(Heating) — Indoor : 70˚FDB, 60˚FWB, Outdoor : 47˚FDB, 43˚FWB
2 : (Heating) — Indoor : 70˚FDB, 60˚FWB, Outdoor : 17˚FDB, 15˚FWB