Linear TMD-90 Home Security System User Manual


 
INSTR,INST,TMD-90
Linear P/N: 208457 E
Material: 20 Lb. Mead Bond
Size: 8.500" x 11.000"
Ink: Black
Scale: 1-1
Front Side 1 of 2
TMD-90
SUPERVISED WIRELESS
PASSIVE INFRARED
MOTION DETECTOR
Installation Instructions
(760) 438-7000 FAX (760) 438-7043
USA & Canada (800) 421-1587 & (800) 392-0123
Toll Free FAX (800) 468-1340
DESCRIPTION The TMD-90 is a passive infrared (PIR)
motion detector with a built-in supervised, digitally-coded radio
transmitter designed for security applications.
The PIR detects motion in its detection pattern by measuring the
infrared emission levels of objects that it “sees”. If the infrared levels
change quickly, as when a person moves across the detection
pattern, the PIR will recognize the change as an intrusion.
A selectable “pulse count” circuit controls the PIR’s triggering of the
transmitter. As a person moves across the detection pattern, the PIR
registers one pulse as each “finger” of the detection pattern is
crossed. The TMD-90 counts these pulses. When the selected
number of pulses occur during the selected time, the PIR will trigger
the transmitter, sending an alarm signal. A lockout timer prevents the
transmitter from triggering more often than once every 2 minutes
when constant motion is detected. The pulse counting and timing
options are selected with the OPTION switch.
The unit is supervised for low battery, alarm and status reporting. The
TMD-90 is compatible with any Linear SX format supervised
security receiver. The transmitter sends hourly status reports. A test
report can be sent by pressing the test button.
Coding switches are not required or used in this transmitter. Each
transmitter is pre-coded at the factory to a unique code. With the SX
format, there are more than sixteen million codes possible.
The transmitter is powered by four Duracell “AA” MN1500 1.5-volt
alkaline batteries (included) and can power the unit for up to 5 years.
When the battery voltage gets low, a low battery report is sent to the
receiver with any alarm, test or status report.
STEP 1 Open detector case. Press in the locking tab and
remove the case cover.
STEP 2 Identify components. Examine the unit to identify
the various components.
STEP 3 Remove circuit board. Remove the adjustment
post and remove the circuit board.
STEP 4 Punch out knockouts. Use a small Phillips
screwdriver to punch out the desired case mounting knockouts.
STEP 5 Mount case. Attach the case to the wall using the
screws and screw anchors provided. Mount the detector in a
location where the intruder’s path will likely cross the
detection pattern beams.
STEP 6 Replace board. Replace the circuit board and
install the adjustment post. Center the detection pattern pointer.
Remove the battery protection strip.
STEP 7 Set option switches. Set the option switches to
select the number of pulses and time frame for alarm. Set
switches 2 & 5 ON, 1, 3 & 4 OFF. Set switch #6 ON to select
walk test mode.
STEP 8 Replace cover. Replace the case cover. Press the
bottom edge until the locking tab engages.
SX
FORMAT!
TOP VIEW
SIDE VIEW
7.5'
(2.29 M)
AB
CD
D
C
B
A
40' (12.19 M)
40' (12.19 M)
A = CREEP ZONES
B = SHORT RANGE ZONES
C = INTERMEDIATE ZONES
D = MAIN ZONES
DETECTION
PATTERN
WINDOW
HEAT
&
COLD
DON'T AIM
AT GLASS
DON'T AIM
AT HEATER
DON'T MOUNT
NEAR VENT
DON'T ALLOW
DIRECT SUNLIGHT
INSTALLATION TIPS
PUSH IN
LOCKING TAB
OPEN
CASE
ANTENNA
TRANSMITTER
TEST BUTTON
TAMPER
SWITCH
OPTION
SWITCH
ADJUSTMENT
POST
WALK TEST
LED
INFRARED
DETECTOR
FOUR TYPE "AA"
BATTERIES
BATTERY
PROTECTION
STRIP
REMOVE
ADJUSTMENT
POST
SLIDE CIRCUIT
BOARD UP
TO REMOVE
PUNCH OUT
SIDE KNOCKOUTS
FOR CORNER MOUNTING
PUNCH OUT
BACK KNOCKOUTS
FOR WALL MOUNTING
LAY BASE ON
CARPET AND
PUNCH OUT
KNOCKOUTS
WITH PHILLIPS
SCREWDRIVER
APPROXIMATELY
7 FEET FROM FLOOR
ARROW ON
CASE POINTS
TO TOP
USE SCREWS AND
ANCHORS TO MOUNT
CASE TO WALL
REPLACE
ADJUSTMENT
POST
CENTER DETECTION
PATTERN POINTER
ON ADJUSTMENT
POST
REMOVE THE
BATTERY
PROTECTION
STRIP
NOTE:
USE DURACELL
MN1500 OR
TOSHIBA LR6G
"AA" ALKALINE
BATTERIES
ONLY!
LOCKING TAB
WILL SNAP SHUT
CLOSE
CASE
SWITCHES 1, 2 & 3
SET NUMBER OF PULSES
2 PULSES
3 PULSES
5 PULSES
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
#1 #2 #3
OPTION SWITCH
SWITCHES 4 & 5 SET TIME
THAT PULSES MUST OCCUR
8 SECONDS
16 SECONDS
32 SECONDS
ON
OFF
OFF
OFF
ON
OFF
#4 #5
SET
SWITCH
#6 ON FOR
WALK TEST