Copyright © 2003 Linear Corporation 220822 A
ERASING SINGLE-CHANNEL TRANSMITTERS ERASING MULTI-BUTTON TRANSMITTERS SETTING RECEIVER OPTIONS
TRANSMITTER COUNT VERIFYING TRANSMITTERS SYSTEM TESTING
HOOKUP: MOOSE Z1100 & CADDX RANGER 9000 HOOKUP: C&K 236 & NAPCO MA1000 LINEAR LIMITED WARRANTY
This Linear product is warranted against defects in material and workmanship for twelve (12)
months. The Warranty Expiration Date is labeled on the product. This warranty extends only
to wholesale customers who buy direct from Linear or through Linear’s normal distribution
channels. Linear does not warrant this product to consumers. Consumers should inquire from
their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or
liabilities on the part of Linear Corporation for consequential damages arising out of or in
connection with use or performance of this product or other indirect damages with respect
to loss of property, revenue, or profi t, or cost of removal, installation, or reinstallation.
All implied warranties, including implied warranties for merchantability and implied warranties
for fi tness, are valid only until Warranty Expiration Date as labeled on the product. This Linear
Corporation Warranty is in lieu of all other warranties express or implied.
All products returned for warranty service require a Return Product Authorization Number (RPA#).
Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.
IMPORTANT !!!
Linear radio controls provide a reliable communications link and fi ll an important need in portable
wireless signalling. However, there are some limitations which must be observed.
✶ For U.S. installations only: The radios are required to comply with FCC Rules and Regulations
as Part 15 devices. As such, they have limited transmitter power and therefore limited range.
✶ A receiver cannot respond to more than one transmitted signal at a time and may be blocked
by radio signals that occur on or near their operating frequencies, regardless of code
settings.
✶ Changes or modifi cations to the device may void FCC compliance.
✶ Infrequently used radio links should be tested regularly to protect against undetected
interference or fault.
✶ A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale
distributor or dealer, and these facts should be communicated to the ultimate users.
ENTERING SINGLE-CHANNEL TRANSMITTERS ENTERING MULTI-BUTTON TRANSMITTERS SETTING TRANSMITTER OPTIONS
PRINTER’S INSTRUCTIONS:
INSTR,INSTL,SXR-64A - LINEAR P/N: 220822 A - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 11.000” X 17.000” - SCALE: 1-1 - SIDE 2 OF 2
OR
RECEIVER CHANNEL NUMBER (64 SHOWN)
ZONE NUMBER (1 SHOWN)
MEMORY LIGHT WILL BE OFF IF THE RECEIVER
CHANNEL IS VACANT (ONLY A VACANT RECEIVER
CHANNEL CAN ACCEPT A TRANSMITTER)
PRESS [MEMORY]
MEMORY LIGHT WILL BLINK, SHOWING THAT THE
RECEIVER IS READY TO ACCEPT A TRANSMITTER
ACTIVATE THE TRANSMITTER
THE MEMORY LIGHT WILL GO ON, SHOWING
THAT THE TRANSMITTER WAS ENTERED AND
THE RECEIVER'S DISPLAYED CHANNEL IS OCCUPIED
WITH THE PANEL DISARMED, PRESS [UP] OR [DOWN]
UNTIL THE DESIRED RECEIVER CHANNEL
NUMBER (1-64) IS DISPLAYED
CHANNEL ZONE
CHANNEL ZONE
PRESS [ADVANCE] TO SELECT THE OUTPUT ZONE
NUMBER (1-8) FOR THE DISPLAYED
RECEIVER CHANNEL NUMBER
RECEIVER CHANNEL NUMBER (64 SHOWN)
ZONE NUMBER (3 SHOWN)
NOTE: ARMING THE CONTROL PANEL ANYTIME
DURING PROGRAMMING WILL CAUSE THE SXR-64A TO
EXIT PROGRAM MODE AND RETURN TO RUN MODE
OR
RECEIVER CHANNEL NUMBER (64 SHOWN)
IGNORE ZONE NUMBER (3 SHOWN)
MEMORY LIGHT WILL BE ON, SHOWING THAT THE
RECEIVER CHANNEL IS OCCUPIED
PRESS [MEMORY]
MEMORY LIGHT WILL BLINK, SHOWING THAT THE
RECEIVER IS READY TO ERASE A TRANSMITTER
FROM THE DISPLAYED RECEIVER CHANNEL
PRESS [MEMORY] AGAIN
MEMORY LIGHT WILL GO OFF, SHOWING
THAT THE TRANSMITTER HAS BEEN ERASED
AND THAT THE RECEIVER'S CHANNEL IS VACANT
WITH THE PANEL DISARMED, PRESS [UP] OR [DOWN]
TO DISPLAY THE RECEIVER CHANNEL NUMBER WITH
THE SINGLE-CHANNEL TRANSMITTER TO ERASE
CHANNEL ZONE
OR
WITH THE PANEL DISARMED,
PRESS [UP] OR [DOWN] UNTIL "Fn" IS DISPLAYED
("Fn" IS BETWEEN "1" AND "64")
"Fn" DISPLAYED (RECEIVER OPTIONS FUNCTIONS)
PRESS [ADVANCE] UNTIL THE DESIRED FUNCTION
LETTER (1-d) IS DISPLAYED
CONFIGURATION OPTION DISPLAYED
(FUNCTION "b" SHOWN)
Fn #
MEMORY LIGHT
OFF
MEMORY LIGHT
ON
ARMED WHEN
ARM=GROUND
ARMED WHEN
ARM=VOLTAGE
TBD
TBD
DISPLAY BLANK
WHEN ARMED
DISPLAY ON AT
ALL TIMES
STATUS ALERTS
AFTER 2 HOURS
STATUS ALERTS
AFTER 8 HOURS
OUTPUTS
NORM. CLOSED
OUTPUTS
NORMALLY OPEN
ONE OF THE
OTHER DELAYS
ENTRY DELAY
0 SECONDS
ENTRY DELAY
20 SECONDS
ONE OF THE
OTHER DELAYS
Fn #
MEMORY LIGHT
OFF
MEMORY LIGHT
ON
ONE OF THE
OTHER DELAYS
ENTRY DELAY
40 SECONDS
ONE OF THE
OTHER DELAYS
ENTRY DELAY
60 SECONDS
EXIT DELAY
0 SECONDS
ONE OF THE
OTHER DELAYS
EXIT DELAY
20 SECONDS
EXIT DELAY
40 SECONDS
EXIT DELAY
60 SECONDS
ONE OF THE
OTHER DELAYS
ONE OF THE
OTHER DELAYS
ONE OF THE
OTHER DELAYS
SET EXIT AND ENTRY DELAYS A LITTLE LONGER
THAN THE CONTROL PANEL'S DELAYS
FUNCTION
FUNCTION OPTION
FOLLOW THE TABLE AND USE THE [MEMORY] BUTTON
AND MEMORY LIGHT TO SELECT FUNCTION OPTIONS
FACTORY DEFAULT SETTINGS
★
★
★
★
★
★
★
★
★
★
★
★
★
★
OR
WITH THE PANEL DISARMED, PRESS [UP] OR [DOWN]
UNTIL THE DESIRED RECEIVER CHANNEL NUMBER
FOR THE MULTI-BUTTON TRANSMITTER IS DISPLAYED
RECEIVER CHANNEL NUMBER (40 SHOWN)
ZONE NUMBER (1 SHOWN)
PRESS [ADVANCE] UNTIL THE DESIRED OUTPUT
ZONE NUMBER (1-8) FOR A TRANSMITTER BUTTON
IS DISPLAYED
RECEIVER CHANNEL NUMBER (40 SHOWN)
ZONE NUMBER (5 SHOWN)
CHANNEL
ZONE
CHANNEL
ZONE
MEMORY LIGHT WILL GO ON, SHOWING THAT THE
BUTTON WAS PROGRAMMED
PRESS [MEMORY]
MEMORY LIGHT WILL BLINK, SHOWING THAT THE
RECEIVER IS READY TO ACCEPT THE TRANSMITTER
BUTTON
PRESS THE DESIRED TRANSMITTER BUTTON (TO
CREATE A DOUBLE-BUTTON LOCKOUT TRANSMITTER,
PRESS TWO BUTTONS AT THE SAME TIME)
REPEAT ZONE SELECTION TO PROGRAM ADDITIONAL
BUTTONS ON THE TRANSMITTER
NOTE: EACH MULTI-BUTTON TRANSMITTER USES ONE RECEIVER
CHANNEL AND A DIFFERENT OUTPUT ZONE FOR EACH BUTTTON
MEMORY LIGHT WILL BE OFF IF THE RECEIVER
CHANNEL IS VACANT (ONLY A VACANT RECEIVER
CHANNEL CAN ACCEPT A TRANSMITTER)
OR
RECEIVER CHANNEL NUMBER (40 SHOWN)
ZONE NUMBER (5 SHOWN)
(THE FIRST ZONE NUMBER ENTERED FOR THE
MULTI-BUTTON TRANSMITTER IS DISPLAYED)
MEMORY LIGHT WILL BE ON, SHOWING THAT THE
RECEIVER CHANNEL IS OCCUPIED WITH A
TRANSMITTER BUTTON LINKED TO THAT ZONE
PRESS [MEMORY]
MEMORY LIGHT WILL BLINK, SHOWING THAT THE
RECEIVER IS READY TO ERASE THE TRANSMITTER
BUTTON FROM THE RECEIVER'S CHANNEL AND ZONE
PRESS [MEMORY] AGAIN
MEMORY LIGHT WILL GO OFF, SHOWING THAT THE
TRANSMITTER BUTTON HAS BEEN ERASED
WITH THE PANEL DISARMED, PRESS [UP] OR [DOWN]
TO DISPLAY THE RECEIVER CHANNEL NUMBER WITH
THE MULTI-BUTTON TRANSMITTER TO ERASE
CHANNEL ZONE
PRESS [ADVANCE] UNITL THE NEXT ZONE NUMBER
USED WITH THE SAME MULTI-BUTTON TRANSMITTER
IS DISPLAYED
CHANNEL ZONE
RECEIVER CHANNEL NUMBER (40 SHOWN)
ZONE NUMBER (6 SHOWN)
REPEAT TO ERASE ANY ADDITIONAL BUTTONS THAT
WERE ENTERED FOR THAT TRANSMITTER
OR
RECEIVER CHANNEL NUMBER (64 SHOWN)
ZONE NUMBER (8 SHOWN)
(FOR MULTI-BUTTON TRANSMITTERS, THE FIRST ZONE
NUMBER ENTERED IS DISPLAYED)
PRESS [ADVANCE] UNTIL THE DESIRED OPTION
LETTER (A-d) IS DISPLAYED
(LETTERS ARE DISPLAYED BETWEEN "8" AND "1")
FOLLOW THE TABLE BELOW AND USE THE [MEMORY]
BUTTON AND MEMORY LIGHT TO SELECT OPTIONS
CONFIGURATION OPTION DISPLAYED
(CHANNEL 64, OPTION "b" SHOWN)
OPTION
MEMORY LIGHT
OFF
MEMORY LIGHT
ON
AUTO-RESTORE TX
(PIR & PORTABLES)
SELF-RESTORE TX
(DOORS & WINDOWS)
NO TX STATUS
REPORTS
TX MAKES STATUS
REPORTS
TX USES ENTRY &
EXIT DELAYS
TRANSMITTER
IS INSTANT
UNARMED ALARM
MEMORY FOR TX
ALARM MEMORY
ONLY WHEN ARMED
CHANNEL
ZONE
CHANNEL
OPTION
WITH THE PANEL DISARMED, PRESS [UP] OR
[DOWN] UNTIL THE DESIRED RECEIVER
CHANNEL NUMBER IS DISPLAYED
FACTORY DEFAULT SETTINGS
★
★
★
★
★
OR
WITH THE PANEL DISARMED,
PRESS [UP] OR [DOWN] UNTIL "Fn" IS DISPLAYED
("Fn" IS BETWEEN "1" AND "64")
"Fn" DISPLAYED (RECEIVER OPTIONS FUNCTION)
PRESS [ADVANCE] UNTIL THE DISPLAY SHOWS
THE OPTION "0"
PRESS [MEMORY]
RECEIVER OPTION "FUNCTION 0"
FUNCTION
FUNCTION OPTION
DISPLAY SHOWS TOTAL NUMBER OF TRANSMITTERS
IN MEMORY FOR 10 SECONDS
# OF TXS
NOTE:
PRESSING [UP] AND [DOWN] TOGETHER ANYTIME
DURING PROGRAMMING WILL CAUSE THE SXR-64A TO
EXIT PROGRAM MODE AND RETURN TO RUN MODE
OR
WITH THE PANEL DISARMED,
PRESS [UP] OR [DOWN] UNTIL "Fn" IS DISPLAYED
("Fn" IS BETWEEN "1" AND "64")
"Fn" DISPLAYED (RECEIVER OPTIONS FUNCTION)
PRESS [ADVANCE] UNTIL THE DISPLAY SHOWS
THE OPTION "E"
PRESS AND RELEASE [MEMORY] THEN WAIT 5 SECONDS
RECEIVER OPTION "FUNCTION E"
FUNCTION
DISPLAY SCROLLS THROUGH EACH CHANNEL AND
LINKED ZONE. VERIFY THAT EACH CHANNEL IS LINKED
TO THE CORRECT ZONE. (THE FIRST ZONE NUMBER
ENTERED FOR A MULTI-BUTTON TRANSMITTER IS
DISPLAYED)
CHANNEL ZONE
FUNCTION OPTION
ACTIVATE EACH TRANSMITTER. WHEN THE RECEIVER
DECODES THE TRANSMITTER, IT WILL BE REMOVED
FROM THE DISPLAY. CONTINUE TESTING UNTIL NO
TRANSMITTERS REMAIN ON THE DISPLAY. PRESS
THE [MEMORY] BUTTON OR WAIT 10 MINUTES TO END
THE TEST.
WITH THE PANEL DISARMED, OPEN A PROTECTED
DOOR OR WINDOW
THE CHANNEL NUMBER AND "O" SHOULD BE
DISPLAYED (CHANNEL 64, OPEN CONDITION SHOWN)
CLOSE THE PROTECTED DOOR OR WINDOW
ARM THE CONTROL PANEL THEN OPEN A PROTECTED
DOOR OR WINDOW (AFTER ANY DELAYS)
THE "O" SHOULD DISAPPEAR WHEN THE TRANSMITTER
RESTORES. DASHES WILL SHOW IF ALL PORTALS
ARE CLOSED.
DISPLAY SHOULD SHOW AN "F" CONDITION FOR THE
FIRST ALARM IN
OPEN ADDITIONAL PROTECTED PORTALS. DISPLAY
SHOULD SHOW AN "A" FOR EACH ADDITIONAL ALARM
SIGNAL SENT. ALARM MEMORY WILL CLEAR WHEN
THE CONTROL PANEL IS DISARMED AND REARMED.
TRANSMITTER
CONDITION
TRANSMITTER
CONDITION
TRANSMITTER
CONDITION
1 2 3 4 5 6 7 8 91011121314151617181920
ZN1 COM ZN2 ZN3 COM ZN4 ZN5 COM ZN6 ZN7 COM ZN8 LB STS COM TMP TST ARM
SXR-64A TERMINALS
MOOSE Z1100
ZN1
1
COM
2
ZN2
3
ZN3
4
COM
5
ZN4
6
ZN5
7
COM
8
ZN6
9
AUX
POWER
2.2K EOL
RESISTORS
(ZONES PROGRAMMED
NORMALLY CLOSED)
(PROGRAMMED FOR
VOLTAGE WHEN ARMED)
ZN7
10
COM
11
ZN8
12
J16
8
28 29
1 2 3 4 5 6 7 8 91011121314151617181920
ZN1 COM ZN2 ZN3 COM ZN4 ZN5 COM ZN6 ZN7 COM ZN8 LB STS COM TMP TST ARM
SXR-64A TERMINALS
CADDX RANGER 9000
ZN1
1
COM
2
ZN2
3
ZN3
4
COM
5
ZN4
6
ZN5
7
COM
8
ZN6
9
AUX
POWER
3.3K EOL
RESISTORS
(ZONES PROGRAMMED
NORMALLY CLOSED)
AUX
OUT
(PROGRAMMED FOR
GROUND WHEN ARMED)
1234
ZN7
10
COM
11
ZN8
12
ZN9
15
ZN10
17
COM
16
ZN11
18
14 13
1 2 3 4 5 6 7 8 91011121314151617181920
ZN1 COM ZN2 ZN3 COM ZN4 ZN5 COM ZN6 ZN7 COM ZN8 LB STS COM TMP TST ARM
SXR-64A TERMINALS
C&K 236
Z1
C
Z2 Z3
C
Z4 Z5
C
Z6
AUX
POWER
2.2K EOL
RESISTORS
(ZONES PROGRAMMED
NORMALLY CLOSED)
(PROGRAMMED FOR
VOLTAGE WHEN ARMED)
1 2 3 4 5 6 7 8 91011121314151617181920
ZN1 COM ZN2 ZN3 COM ZN4 ZN5 COM ZN6 ZN7 COM ZN8 LB STS COM TMP TST ARM
SXR-64A TERMINALS
NAPCO MA1000e
ZN1
15
COM
14
ZN2
16
ZN3
17
ZN4
19
ZN5
20
COM
18
ZN6
21
AUX
POWER
2.2K EOL
RESISTORS
(ZONES PROGRAMMED
NORMALLY CLOSED)
(PROGRAMMED FOR
GROUND WHEN ARMED)
56
NOTE: THIS PANEL DOES NOT
SUPPLY AN ARMED SIGNAL.
USE A PUSHBUTTON TO
RESET THE ALARM MEMORY
WHEN THE PANEL IS ARMED.
SET SXR-64A DELAYS TO "0"
AUX
C
RESET
E3 PGM