Linear DX-COKIT Carbon Monoxide Alarm User Manual


 
Copyright © 2007 Linear LLC 228124 A
ANTENNA INSTALLATION TERMINAL CONNECTION BUTTON AND INDICATOR FUNCTIONS
FUNCTION
PROGRAM
BUTTON
PROGRAM
INDICATOR
NORMAL
OPERATION
RELEASES
LATCHED RELAY
FOR CHANNEL
1 OR 2
LIGHTS WHEN
TRANSMITTER
IS RECEIVED,
FLASHES WHEN
INTERFERENCE IS
RECEIVED
PROGRAMMING
MEMORY
PRESS AND
RELEASE FOR
CHANNEL 1 OR 2
LIGHTS FOR 3
SECONDS FOR
PROGRAMMING
CHECKING
MEMORY
PRESS FOR
CHANNEL 1 OR 2
UNTIL BLINK AND
RELEASE
BLINKS THE NUMBER
OF TRANSMITTERS IN
CHANNEL MEMORY
ERASING
MEMORY
FOR CHANNEL 1
OR 2, PRESS AND
HOLD THROUGH
THE COUNT AND
HOLD FOR 5
SECONDS MORE
AFTER BLINKING
COUNT. A PAUSE
THEN A SINGLE
BLINK AS MEMORY
IS ERASED (DOUBLE
BLINK ON CHANNEL 2)
PROGRAMMING MEMORY CHECKING MEMORY SYSTEM TESTING
ERASING MEMORY LINEAR LIMITED WARRANTY
This Linear product is warranted against defects in material
and workmanship for twenty-four (24) months. The Warranty
Expiration Date is labeled on the product. This warranty
extends only to wholesale customers who buy direct from
Linear or through Linear’s normal distribution channels. Linear
does not warrant this product to consumers. Consumers
should inquire from their selling dealer as to the nature of the
dealer’s warranty, if any. There are no obligations or liabilities
on the part of Linear LLC for consequential damages
arising out of or in connection with use or performance
of this product or other indirect damages with respect
to loss of property, revenue, or profi t, or cost of removal,
installation, or reinstallation. All implied warranties, including
implied warranties for merchantability and implied warranties for
fi tness, are valid only until Warranty Expiration Date as labeled
on the product. This Linear LLC Warranty is in lieu of all other
warranties express or implied.
All products returned for warranty service require a Return
Product Authorization Number (RPA#). Contact Linear Technical
Service at 1-800-421-1587 for an RPA# and other important
details.
IMPORTANT
Linear radio controls provide a reliable communications link and
fi ll an important need in portable wireless signalling. However,
there are some limitations which must be observed.
For U.S. installations only: The radios are required to comply
with FCC Rules and Regulations as Part 15 devices. As such,
they have limited transmitter power and therefore limited
range.
A receiver cannot respond to more than one transmitted signal
at a time and may be blocked by radio signals that occur on or
near their operating frequencies, regardless of code settings.
• Changes or modifi cations to the device may void FCC
compliance.
Infrequently used radio links should be tested regularly to
protect against undetected interference or fault.
A general knowledge of radio and its vagaries should be
gained prior to acting as a wholesale distributor or dealer, and
these facts should be communicated to the ultimate users.
1. PRESS PROGRAM BUTTON FOR THE
DESIRED CHANNEL AND HOLD FOR ABOUT
TWO SECONDS UNTIL INDICATOR LIGHTS
THEN RELEASE.
2. COUNT THE NUMBER OF INDICATOR BLINKS,
THIS IS THE TOTAL NUMBER OF
TRANSMITTERS PROGRAMMED INTO THAT
CHANNEL.
PUSH UNTIL
INDICATOR LIGHTS
NOTE: DO NOT CONTINUE TO PRESS
BUTTON OR MEMORY WILL BE ERASED
1. ACTIVATE EACH TRANSMITTER,
ONE AT AT TIME.
2. LISTEN FOR RELAY CLICK IN
THE RECEIVER.
3. VERIFY THAT THE DEVICE CONNECTED
TO THE RECEIVER RESPONDS AND THAT
THE PROPER CHANNEL ACTIVATES.
PRESS AND HOLD THE
TEST SWITCH FOR
20 SECONDS TO SEND
AN ALARM SIGNAL
1. PRESS PROGRAM BUTTON
FOR THE CHANNEL TO ERASE
AND CONTINUE TO HOLD IT
THROUGH THE COUNT OF THE
TRANSMITTERS.
2. CONTINUE TO HOLD THE
BUTTON AFTER THE COUNT
UNTIL THE INDICATOR BLINKS
ONCE FOR CHANNEL ONE,
TWICE FOR CHANNEL TWO
(ABOUT FIVE SECONDS
AFTER THE COUNT).
3. ALL TRANSMITTERS
PROGRAMMED INTO
THAT CHANNEL
WILL BE ERASED.
PUSH AND HOLD BUTTON
FOR FIVE SECONDS AFTER
THE TRANSMITTER COUNT
THE DXS-80 CO ALARM THAT
IS INCLUDED IN THE COKIT IS
ALREADY PROGRAMMED INTO
THE ASSOCIATED DXR-702
RECEIVER. TO PROGRAM
MORE DXS-80 CO ALARMS
INTO THE RECEIVER USE
THE FOLLOWING PROCEDURE.
1. PRESS AND RELEASE
PROGRAM BUTTON FOR THE
DESIRED CHANNEL. IF LOW
BATTERY REPORTING IS
DESIRED, BE SURE TO
LEAVE CHANNEL TWO
EMPTY.
2. PROGRAM INDICATOR WILL
LIGHT FOR 10 SECONDS IF
THERE IS ROOM IN THAT
CHANNEL'S MEMORY FOR
ANOTHER TRANSMITTER
(32 TRANSMITTERS MAXIMUM
TOTAL ALLOWED BETWEEN
BOTH CHANNELS IN THE
RECEIVER).
3. WITHIN 10 SECONDS, SEND
SIGNAL FROM TRANSMITTER,
PROGRAM INDICATOR WILL
FLICKER AS SIGNAL IS
RECEIVED.
4. REPEAT THE ABOVE THREE
STEPS FOR EACH
ADDITIONAL TRANSMITTER.
AFTER PUSHING THE RECEIVER'S
PROGRAMMING BUTTON, YOU ONLY HAVE
10 SECONDS TO SEND A SIGNAL BEFORE
PROGRAMMING MODE STOPS
PRESS UNTIL ALARM
BEEPS THEN RELEASE
TEST BUTTON TO
SEND SIGNAL
A TEST SIGNAL WILL BE SENT A
FEW SECONDS AFTER THE
SWITCH IS RELEASED
PRINTER’S INSTRUCTIONS:
INSTR,INSTL,DX-COKIT - LINEAR P/N: 228124 A - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 11.000” X 8.500” - SCALE: 1-1 - SIDE 2 OF 2
SCREW LOCAL
WHIP ANTENNA
ONTO RECEIVER
- OR -
USE REMOTE
ANTENNA
UP TO 25 FEET
OF RG-59 CABLE
ALLOWED
MODEL
EXA-1000
ANTENNA
ANTENNA NOTES:
1. ANTENNA SHOULD BE MOUNTED
AS HIGH AS PRACTICAL.
2. KEEP ANTENNA AWAY FROM
ELECTRICAL INTERFERENCE
SOURCES.
3. CENTRALLY LOCATE ANTENNA
AMONG THE TRANSMITTERS.
N.O.
COM
N.C.
N.O.
COM
N.C.
DXR-702 TERMINALS
ALARM
LOOP
N.C. OR N.O.
TROUBLE
LOOP
N.C. OR N.O.
AUX.
POWER
ALARM PANEL CONNECTION WITH LOW BATTERY REPORTING
LATCHING RELAY OPTION
NOTE:
CHANNEL 2 MUST
BE EMPTY TO
REPORT LOW
BATTERY