Linear DF-72/EC Smoke Alarm User Manual


 
STEP 7 Attach DF-72/EC to mounting plate. Match up
alignment tabs on detector and plate. Turn detector clockwise
until it locks in place.
STEP 8 Test smoke detector. Set the console into a test
mode. Press and hold the smoke detector test button. Con-
tinue to hold the test button for at least 30 seconds after the
noisemaker starts. Verify that the signal was received.
NFPA 74 STANDARD FOR SMOKE DETECTOR LOCATION
The DF-72/EC should be installed in accordance with National Fire Protection Association
(NFPA) Standard 74, which reads as follows:
2-1.1.1Smoke detectors shall be installed outside of each separate sleeping area in the
immediate vicinity of the bedrooms and on each additional story of the family living unit
including basements and excluding crawl spaces and unfi nished attics*.
The provisions of 2-1.1.1 represent the minimum number of detectors required by this
standard. It is recommended that the householder consider the use of additional smoke or heat
detectors for increased protection for those areas separated by a door from areas protected
by the required smoke detectors under 2-1.1.1 above. The recommended additional areas
are: living room, dining room, bedroom(s), kitchen, attic (fi nished or unfi nished), furnace
room, utility room, basement, integral or attached garage and hallways not covered under 2-
1.1.1 above. However, the use of additional detectors remains the option of the householder.
2-1.1.2 For family living units with one or more split levels (i.e., adjacent levels with less than
one full story separation between levels), a smoke detector required by 2-1.1.1 shall suffi ce
for an adjacent lower level, including basements.
MATCH UP
ALIGNMENT
TABS
TWIST DETECTOR
CLOCKWISE TO
LOCK TO MOUNTING
PLATE
E
M
E
R
G
E
N
C
Y
PLACE CONSOLE IN OFF MODE
TO STOP SIREN, CHECK THAT THE
SENSOR STATUS LIGHT IS BLINKING
PRESS AND HOLD DETECTOR
TEST BUTTON, SMOKE
DETECTOR'S BEEPER WILL
START TO SOUND
CONTINUE TO HOLD THE SMOKE
DETECTOR'S TEST BUTTON FOR
ABOUT 30 SECONDS UNTIL
THE CONSOLE'S SIREN STARTS
NFPA 74 STANDARD FOR SMOKE DETECTOR LOCATION
Exception: Where there is an intervening door between one level and the adjacent
lower level, a smoke detector shall be installed on the lower level.
Ceiling mounted smoke alarms should be located in the center of the room or hall,
or not less than 4 inches (10 cm) from any wall. When the detector is mounted on
a wall, the top of the detector should be 4 to 12 inches (10-30 cm) from the ceiling.
Do not install smoke alarms where normal ambient temperatures are above 100°F (37.8°C),
or below 40°F (4°C). Also, do not locate alarm in front of air conditioners, heating registers,
or other locations where normal air circulation will keep smoke from entering the detector.
FIRE PREVENTION AND ESCAPE
The purpose of an early warning smoke alarm is to detect the presence of fi re in its early stages,
and sound an alarm giving the occupants more time to exit the premise before the smoke reaches
a dangerous concentration level.
Fires start even with the best of housekeeping and fi re prevention procedures. Fire is an
unexpected event. Early warning detection alerts occupants in time to act.
KNOW FIRE HAZARDS. No detection device can protect life in all situations. Therefore,
safeguards should be taken to avoid such potentially dangerous situations as: smoking
in bed, leaving children home alone, cleaning with fl ammable liquids such as gasoline.
FIRE PREVENTION AND ESCAPE
The best fi re protection is minimizing fi re hazards through proper storage of materials and general
good housekeeping techniques. A cluttered basement, attic, or other storage area is an open
invitation to fi re. Careless use of combustible materials and electrical appliances, or overloading
of electrical outlets are other prime causes in starting fi res.
It is most important that explosive and/or fast burning materials be eliminated from the home, if
at all possible.
Even after proper precautions have been taken, fi res can start. Be prepared.
IN CASE OF FIRE. Leave immediately. Don’t stop to pack or search for valuables. In heavy
smoke, hold your breath and stay low - crawl if necessary. The clearest air is usually at the fl oor.
If you have to go through a closed door, carefully feel the door and door knob to see if undue heat
is present. If they seem relatively cool, brace your foot against the bottom of the door with your hip
against the door and one hand against the top edge. Open it slightly. If a rush of hot air is felt, slam
the door quickly and latch it. Unvented fi re tends to build up considerable pressure. Be sure all the
household realizes and understands this danger.
Use your neighbor’s phone or a street fi re alarm box. The job of extinguishing the fi re should be
left to the professionals. Too many unforeseen things can occur when inexperienced people try
to extinguish a fi re.
FIRE PREVENTION AND ESCAPE
BE PREPARED. Perform fi re drills regularly. Use them to assure recognition of an alarm signal.
For your protection, simulate different circumstances (smoke in hall, in living room, etc.). Then
have everyone react to the situation.
Draw a fl oor plan and show two exits from each room. Frequently a knotted rope or ladder from a
window will serve this purpose. It is important that children be instructed carefully, because they
tend to hide in times of crisis.
It is imperative that one meeting place outside the home be established. You should insist that
everyone meet there during an alarm. This will eliminate the tragedy of someone reentering the
house for a missing member who is actually safe.
If you have children and/or invalids residing in your household, you can help your fi re department.
Most fi re departments have window decals available for use in children’s or invalid’s bedrooms.
Properly used, these decals will quickly identify sleeping quarters of these individuals and show
the fi re department where to look fi rst for members of your household.
Additional information on Household Fire Warning is available at nominal cost from: The
National Fire Protection Association, Batterymarch Park, Quincy, MA 02269. Request
Standard No. NFPA 74.
INTERNATIONAL WARRANTY
This Linear product is warranted against defects in material and workmanship for twelve (12) months. The Warranty Expiration
Date is labeled on the product. This warranty extends only to wholesale customers who buy direct from Linear or through
Linear’s normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from
their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of Linear
Corporation for consequential damages arising out of or in connection with use or performance of this product or other
indirect damages with respect to loss of property, revenue, or profi t, or cost of removal, installation, or reinstallation.
All implied warranties, including implied warranties for merchantability and implied warranties for fi tness, are valid only until
Warranty Expiration Date as labeled on the product. This Linear Corporation Warranty is in lieu of all other warranties
express or implied. For warranty service on Linear equipment return product, at sender’s expense to:
Linear Hong Kong 19/F Hounor Industrial Centre, 6 Sun Yip Street Chai Wan, Hong KongAttention: Repairs Department
REPAIRS POLICY
Charges will be made for equipment that is not in warranty, shows customer abuse, or is damaged by the effects of lightning,
water, fi re, or other abnormal happenings.Customer’s equipment sent in for repair may be repaired or replaced with new or
remanufactured equipment at Linear’s discretion.The customer is always responsible for shipping and handling charges to the
repairs facility. Linear will pay return shipping and handling charges on “in warranty” products shipped back to the customer.
The customer will be billed for the return shipping and handling charges on “out of warranty” products.There will be a 50%
expedite fee for any express requests.The International Sales Manager must be notifi ed prior to the return of product to Linear.
All international returns must have an International Repair Authorization number (IRA#). The number must be marked on all
packages. Failure to do so will cause delays in processing.
IMPORTANT !!!
Linear radio controls provide a reliable communications link and fi ll an important need in portable wireless signaling. However,
there are some limitations which must be observed. The radios are required to comply with local rules and regulations as radio
devices. As such, they have limited transmitter power and therefore limited range.A receiver cannot respond to more than one
transmitted signal at a time and may be blocked by radio signals that occur on or near their operating frequencies, regardless
of code settings. Changes or modifi cations to the device may void regulatory compliance. Infrequently used radio links should
be tested regularly to protect against undetected interference or fault. A general knowledge of radio and its vagaries should be
gained prior to acting as a wholesale distributor or dealer, and these facts should be communicated to the ultimate users.
Copyright © 2003 Linear Corporation 211048 C
DINING
KITCHEN
BEDROOM BEDROOM
BEDROOM
LIVING
ROOM
SMOKE
DETECTOR
A smoke alarm should be
located between the sleeping area
and the rest of the family living unit.
DINING
KITCHEN
BEDROOM
TV
ROOM
BEDROOM
LIVING
ROOM
BEDROOM
In family living units with more
than one sleeping area, a smoke
alarm should be provided to
protect each.
SMOKE
DETECTORS
LIVING
ROOM
BASEMENT
HALL
BED
ROOM
BED
ROOM
Indicates required smoke detector
Indicates optional smoke detector
if door is not provided between
Living and Recreation Rooms
RECREATION ROOM
BASEMENT
HALL
BED
ROOM
BED
ROOM
LIVING
ROOM
DINING
ROOM
A smoke detector should be
located on each story.
R&TTE VAEE 27802, EMC, SFT, ETS
Linear Corporation declares that the apparatus DF-72/EC
complies with the essential requirements and other
relevant provisions of Directive 1995/5/EC.
PRINTER’S INSTRUCTIONS:
INSTR,INSTL,DF-72/EC - LINEAR P/N: 211048 C - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 11.000” X 8.500” - SCALE: 1-1 - SIDE 2 of 2