Lightolier WES SERIES 1X4 Indoor Furnishings User Manual


 
CLEANGUARD WET LOCATION WES SERIES 1X4
Page 2 of 2 1' x 4' RECESSED FLUORESCENT, FOR WET LOCATIONS, COVERED CEILING USE
1 OR 2 LAMPS, T8 OR T12
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902 SECTION 6/Folio N30-10
Job Information Type:
OPTIONS & ACCESSORIES
SPECIAL LENSES: Substitute VI for VA (standard) .125" nominal pattern 12
with 6.8 oz. average weight per square foot.
ACCESS PLATE: Top wiring access plate is shipped with fixture as standard.
When access plates are required in advance for wiring convenience, specify
separately. Order Catalog Number: ACP CSP.
CONTINUOUS ROW INSTALLATION: For F type fixtures, half-width flanges
are required between fixtures. Order Catalog Number: 1FC TRIM (each joint).
PLASTER FRAMES: F type fixtures do not include plaster frames. For individ-
ual or continuous mounting, specify PF14 universal frame per fixture.
ELECTRICAL/WIRING OPTIONS: Consult factory.
SEISMIC HOLD-DOWN CLIP: For type G troffers. SUFFIX: 2HD.
FUSING: Internal fast-blow fusing. SUFFIX: GLR.
Internal slow-blow fusing. SUFFIX: GMF.
RADIO INTERFERENCE FILTER 120 or 277 volt, 50 or 60 Hz. One per fixture
is standard. SUFFIX: RF.
DRYWALL KIT: Order Catalog Number: FK91X4. Request Folio OA30-10.
CHICAGO PLENUM: SUFFIX: CP.
SPECIFICATIONS
PERFORMANCE: In an installation of 2 lamp 32W luminaires in a room cavity
ratio of 1, with reflectance of 80% ceiling, 50% wall, 20% floor, the C.U. shall not
be less than .68. To prevent glare the VCP shall not be less than 46 either length-
wise or crosswise (at 100fc level) and the average brightness at 65° shall not
exceed 682 footlamberts. To control veiling reflections, luminaire output in the
30°-90° zone shall not be less than 66.4%.
MATERIALS: Chassis parts are die-formed code gauge cold rolled steel.
Housing is contoured for rigidity with all edges turned up for safe handling. Lens
frame—(FS) flat full-size steel frame, (FA) flat full-size extruded
aluminum frame, (RA) regressed full-size extruded aluminum frame.
FINISH: Chassis exterior—black baked polyester enamel. Cavity—white
baked polyester enamel minimum 86% reflectance. Phosphate undercoating.
LENSES: VA (standard) extruded virgin acrylic, 3/16" square based female cones,
running 45° to the panel edge, .095" nominal thickness (similar to pattern 12).
ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°.
LABELS: I.B.E.W./UL and C-UL.
PHOTOMETRY MODEL NO. WES1GFSVA232
ORDERING INFORMATION
Explanation of Catalog Number. Example: WES1GFSVA232120SOGLR
WE
CLEANGUARD
WET
LOCATION
S
STATIC
1
FIXTURE
WIDTH
CEILING TYPE:
G= Grid
(lay-in T bar)
F=Flanged
(overlap)
Z spline and
plaster frame
LENS FRAME:
FS= Flat steel
frame
FA=Flat aluminum
frame
RA=Regressed alu-
minum frame
LENS/
SHIELDING
TYPE:
VA=Virgin acrylic
(standard), see
options and
consult factory
LAMP
QUANTITY:
1 or 2 Lamps
LAMP/
FIXTURE LENGTH:
32=T8
34=T12
(Nominal 48")
VOLTAGE:
120 or 277
BALLAST TYPE:
2 Lamp Mag. T12 LE
<20THD <10THD
2 Lamp Elec. T8 SO* H
I*
LOL T8 Dimming PS
*Instant Start Standard
OPTIONS:
Add appropriate
suffix to catalog
no., ie: (GLR)
coefficients of utilization — zonal cavity method
RF 20 20 20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1716866 646261 616059
2656157 575552 555351
3605550 524845 504745
4564944 474340 454239
5514439 423835 413734
6484035 383431 373330
7443631 353027 343027
8413227 312724 302623
9372924 282421 272320
10 35 27 22 26 21 18 25 21 18
visual comfort probability (VCP) average 100 fc; reflectances 80/50/20
room size ceiling height ceiling height
W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0
20 20 60 64 70 77 61 65 70 76
20 30 51 56 61 67 54 57 62 68
20 40 47 50 55 60 51 53 57 61
20 60 43 46 59 54 49 50 52 56
30 20 62 66 70 75 63 67 70 75
30 30 53 57 61 65 55 58 62 66
30 40 48 51 54 58 51 53 56 60
30 60 44 46 48 52 49 50 51 54
30 80 42 44 44 48 48 49 49 51
40 20 64 68 72 75 64 68 72 75
40 30 55 59 63 66 57 60 63 66
40 40 49 52 55 59 53 54 57 60
40 60 45 47 49 52 50 51 51 54
40 80 43 45 45 48 49 50 49 50
40 100 42 43 43 45 50 49 48 49
60 30 57 60 64 67 58 61 64 67
60 40 51 53 56 60 54 55 57 60
60 60 46 48 49 52 50 51 51 54
60 80 44 45 45 48 49 50 49 50
60 100 43 43 42 45 50 49 47 48
100 40 55 57 59 62 57 58 59 63
100 60 50 51 52 55 53 54 53 56
100 80 47 48 47 50 52 52 50 52
100 100 46 46 44 46 52 51 49 49
room cavity ratio
luminaries lengthwise
luminaries crosswise
LER = FL - 48.3 IW - 80.0 BF - 0.95
Comparative yearly lighting energy cost per 1000 lumens = $5.00
Other dimming options. Consult factory.