Lightolier VTS2GPK3FT Indoor Furnishings User Manual


 
VIDEO TELECONFERENCE LUMINAIRE VTS2GPK3FT
Page 2 of 2 2'x2' RECESSED FLUORESCENT
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902 SECTION 5/Folio K05-10
Job Information Type:
OPTIONS & ACCESSORIES
RADIO INTERFERENCE FILTER 120 or 277 volt, 50 or 60 Hz. One per fixture.
SUFFIX: RF.
ELECTRICAL/WIRING OPTIONS Consult factory.
DRYWALL KIT: Order Catalog Number: FK92X2. (Request Folio OA30-10).
CHICAGO PLENUM: SUFFIX: CP.
SPECIFICATIONS
MATERIALS: Chassis parts are die formed code gauge cold rolled steel.
Housing side rails hemmed over and housing ends turned-in for safe handling.
Parabolic Blades–pre-anodized specular aluminum (Coilzak® or equal).
Lens–High quality glare control lens with square based male conical prisms.
FINISH: Chassis exterior–black baked polyester enamel. Cavity–white
baked polyester enamel minimum 86% reflectance. Phosphate undercoating.
ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB.
If K.O. is within 3" of ballast, use wire suitable for at least 90°.
LABELS: I.B.E.W./UL and ULc listed.
PHOTOMETRY MODEL NO. VTS2GPK3FT120X3
coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)
RF 20 20 20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1626059 575554 555453
2585552 525048 504947
3545047 484543 464442
4514642 444139 434038
5484238 403735 393734
6453935 373431 363331
7423632 353129 343129
8393329 322926 312826
9373127 302724 292624
10 35 29 25 28 25 22 27 24 22
visual comfort probability (rated lumens per lamp 3150.)
room size ceiling height ceiling height
W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0
20 20 94 92 89 81 82 77 76 75
20 30 95 93 92 85 84 78 72 70
20 40 96 93 92 87 86 80 73 69
20 60 96 94 93 85 87 82 76 70
30 20 94 91 89 81 82 79 80 76
30 30 95 92 91 85 86 80 75 71
30 40 95 93 91 85 88 83 76 69
30 60 95 93 93 85 89 84 79 70
30 80 95 94 93 85 89 86 81 70
40 20 94 92 90 81 83 79 80 79
40 30 95 92 92 85 86 80 77 74
40 40 96 93 92 85 99 93 78 72
40 60 96 94 93 85 89 85 80 73
40 80 95 94 93 85 90 86 82 73
40 100 95 94 94 85 90 87 84 73
60 30 95 93 92 85 86 80 77 74
60 40 96 93 92 86 88 83 78 72
60 60 96 94 93 86 90 85 81 74
60 80 95 94 93 86 90 87 83 75
60 100 95 94 94 86 90 88 85 75
100 40 96 93 92 87 88 83 78 73
100 60 96 94 92 87 90 86 81 74
100 80 95 94 93 87 91 88 84 75
100 100 95 94 94 87 91 89 85 76
room cavity ratio
luminaries lengthwise
luminaries crosswise
ORDERING INFORMATION
Explanation of Catalog Number. Example: VTS2GPK3FT120X3GLR
Other dimming options. Consult factory.
LER = FP - 42.9 WATTS - 102.6 BF - 0.85
Comparative yearly lighting energy cost per 1000 lumens = $5.59
VT
VT:
Video
Teleconference
Luminaire
S
BODY STYLE:
S=Static
2
FIXTURE
WIDTH
CEILING TYPE:
G= Grid
(lay-in T bar)
T= Slot Grid
PK
INTEGRATED
SHIELDING
LAMP
QUANTITY
2=2 Lamp
3=3 Lamp
LAMP TYPE/
FIXTURE
LENGTH:
6U=6"U Lamp T8
(2 Lamp Only)
FT=
Twin Tube T5
(Nominal 24")
VOLTAGE:
120 or 277
OPTIONS:
Add appropriate
suffix to catalog
no, ie: (GLR)
BALLAST TYPE:
<20THD <10THD
1 & 2 Lamp Elec. T8 SO* H
I*
1 & 2 Lamp Elec. TT5 SB*
IB*
(40 watt)
1-3 Lamp Elec. T8 O3* H3*
1-3 Lamp Elec. TT5 X3*
I3*
(40 watt)
LOL T8 Dimming PS
LOL TT5 Dimming PB
*Instant Start Standard
Blank=Standard
N=NYC Code
G02032
VTS2GPK3FT120X3