Lightolier VRB Series Indoor Furnishings User Manual


 
VISION SMART PARABOLIC (VRB) VRB SERIES 1'x4'
Page 2 of 2 1'x4' SURFACE BOX FLUORESCENT, 3" DEEP PARABOLIC LOUVER
IES RP1 FOR NORMAL VDT USE, 1 OR 2 LAMP T8, T12
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902 SECTION 2/Folio G05-72 REV. A
Job Information Type:
OPTIONS & ACCESSORIES
FUSING: Internal fast-blow fusing.
SUFFIX: GLR.
Internal slow-blow fusing.
SUFFIX: GMF.
RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz.
One per fixture. SUFFIX: RF.
ELECTRICAL/WIRING OPTIONS: Consult factory.
STEM AND CANOPY SETS: Suspends fixture 6", 12", 18" or 24" from surface.
(Four per fixture is required). Catalog Number: ASC6 CSP (6"), ASC18 CSP
(12"), ASC18 CSP (18"), ASC24 CSP (24").
SPECIFICATIONS
PERFORMANCE: In an installation of 1 lamp 32W luminaires in a room cavity
ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be
less than .71 with a spacing to mounting ratio of 1.9 perpendicular to the lamp.
To meet IES RP-1 recommended (basic) requirements for VDT areas the VCP
(visual comfort probability) shall not be less than 90 either crosswise or length-
wise and the maximum average brightness at 65°, 75° and 85° shall not
exceed 592, 109 and 81 candelas per square meter respectively in the 0°, 45°
and 90° horizontal planes. Candelas at Nadir (0°) not to exceed 671.
SPECIFICATIONS (continued)
MATERIALS: Chassis parts are die-formed 20 gauge cold rolled steel with
45° mitered corners welded and turned in edges for safe handling.
LOUVER: Pre-anodized aluminum (Coilzak® or equal).
FINISH: Louver—semi-specular low iridescence, pre-anodized reflector sheet.
Cavity—white baked acrylic minimum reflectance 86%, Phosphate undercoat-
ing. Chassis exterior—white baked acrylic enamel.
ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB.
If K.O. is within 3" of ballast, use wire suitable for at least 90°.
LABELS: I.B.E.W./UL and C-UL listed.
PHOTOMETRY MODEL NO. VRB1S8LS132120SO
ORDERING INFORMATION
Explanation of Catalog Number. Example: VRB1S8LS132120SOGLR
VR
VR
3" Deep
Pre-
anodized
Aluminum
Louver
B
BODY STYLE:
Surface Box
1
FIXTURE
WIDTH:
S
CEILING
TYPE:
S=Surface
NUMBER OF
CELLS:
8= 1 row of
8 cells
12= 1 row of
12 cells
16= 2 rows of
8 cells
24= 2 rows of
12 cells
L
LOUVER FINISH:
L= Low-iridescence
Semi-specular
P= Low-iridescence
Specular
S
WHITE
REFLECTOR
LAMP
QUANTITY:
1 lamp
2 lamp
LAMP/
FIXTURE
LENGTH:
32=T8
34=T12
(Nominal 48")
VOLTAGE:
120 or 277
BALLAST TYPE:
1 or 2 Lamp Mag. T12 LE
<20THD
<10THD
1 or 2 Lamp Elec. T8 SO* H
I*
LOL Dimming T8 PS
*Instant Start Standard
Other dimming options, consult factory.
OPTIONS:
Add appropriate suffix to cat-
alog no., ie: (GLR)
coefficients of utilization — zonal cavity method
RF 20 20 20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1737169 676564 646362
2686460 605755 585654
3635752 545047 524947
4585146 484441 474341
5534640 443936 423936
6494136 403532 383431
7463732 363128 353128
8423429 332825 322825
9403126 302622 292522
10 37 29 24 28 23 20 27 23 20
visual comfort probability
room size ceiling height ceiling height
W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0
20 20 90 87 82 86 88 85 80 78
20 30 91 89 86 84 90 87 82 78
20 40 92 90 88 86 90 88 85 80
20 60 93 91 89 88 90 88 86 83
30 20 91 89 84 84 88 88 82 79
30 30 92 91 87 82 90 90 84 78
30 40 93 92 89 84 90 90 86 80
30 60 94 93 90 86 90 90 87 83
30 80 94 93 90 86 90 90 87 83
40 20 91 89 85 85 88 88 84 80
40 30 93 91 88 83 90 90 86 80
40 40 94 92 80 85 90 90 88 82
40 60 94 93 91 87 90 90 88 84
40 80 94 92 91 87 90 90 88 84
40 100 94 92 91 87 90 90 88 84
60 30 93 91 88 85 90 90 86 81
60 40 93 92 90 87 90 90 88 83
60 60 94 93 91 88 90 90 88 85
60 80 94 93 91 88 91 90 88 85
60 100 94 93 91 88 91 90 88 85
100 40 93 92 90 87 90 90 88 83
100 60 94 93 91 88 91 90 88 85
100 80 94 93 91 89 91 90 88 85
100 100 94 93 91 89 91 90 88 86
room cavity ratio
luminaries lengthwise
luminaries crosswise
LER = FP - 25.9 IW - 63.8 BF - 0.88
Comparative yearly lighting energy cost per 1000 lumens = $9.26