Lightolier VRA1G12LS132 Indoor Furnishings User Manual


 
VR PARABOLIC VRA1G12LS132
Page 2 of 2 1'x4' RECESSED FLUORESCENT, 3" DEEP, 12 CELL (1 ROW) PARABOLIC LOUVER
STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR NORMAL VDT USE
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902 SECTION 2/Folio G05-37 REV. A
Job Information Type:
PHOTOMETRY MODEL NO. VRA1G12LS132120SO
coefficients of utilization — zonal cavity method
RF 20 20 20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1696765 636160 615958
2646158 585553 565452
3605551 524947 514846
4565045 484441 464341
5514540 433936 423836
6474036 393532 383432
7443631 353128 343028
8403227 312724 302724
9372924 282320 272320
10 34 26 21 25 21 18 24 21 18
visual comfort probability
room size ceiling height ceiling height
W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0
20 20 95 94 92 88 90 85 81 80
20 30 96 94 93 90 90 88 82 77
20 40 96 95 93 92 90 88 83 79
20 60 96 95 94 92 90 88 84 79
30 20 95 94 92 87 90 87 85 82
30 30 96 95 94 89 90 89 85 79
30 40 96 95 94 91 90 88 86 80
30 60 97 96 95 91 91 88 86 80
30 90 97 96 95 91 91 88 86 80
40 20 95 95 93 88 90 87 85 84
40 30 96 95 94 90 90 88 86 82
40 40 97 95 94 91 91 88 87 82
40 60 97 96 95 91 91 88 87 82
40 80 97 96 95 91 91 88 87 83
40 100 97 96 95 91 91 88 87 83
60 30 96 95 94 91 91 88 86 82
60 40 97 96 94 92 91 88 87 83
60 60 97 96 95 92 91 89 87 83
60 80 97 96 95 92 91 89 87 83
60 100 97 96 95 92 91 89 87 83
100 40 97 95 94 92 91 88 87 83
100 60 97 96 95 92 91 89 87 83
100 80 97 96 95 92 91 89 87 83
100 100 97 96 95 92 91 89 87 83
room cavity ratio
luminaries lengthwise
luminaries crosswise
ORDERING INFORMATION
Explanation of Catalog Number. Example:VRA1G12LS132120SOGLR
VR
VR:
3" Deep
Pre-
anodized
Aluminum
Louver
for normal
VDT use
BLANK = Standard
N = NYC Code
BODY STYLE:
A=Air Handling
S=Static
1
FIXTURE
WIDTH
CEILING TYPE:
G= Grid (lay-in T bar)
F=Flanged (overlap)
Z spline and
plaster frame
T=Slot grid or
two-directional
concealed T
(see options)
12
NUMBER OF
CELLS:
1 row of
12 cells
LOUVER
FINISH:
L=Low
Iridescence
Semi-specular
(standard)
P=Low
iridescence
specular
S
SINGLE
WHITE
REFLECTOR
1
LAMP
QUANTITY
LAMP/
FIXTURE
LENGTH:
32=T8
34=T12
(Nominal 48")
VOLTAGE:
120 or 277
BALLAST TYPE:
1 Lamp Mag. T12 LE
<20THD <10THD
1 Lamp Elec. T8 SO* H
I*
LOL Dimming PS
*Instant Start Standard
Other dimming options, consult factory.
OPTIONS:
Add appropriate
suffix to catalog
no, ie: (GLR)
LER = FP - 50.1 IW - 30.6 BF - 0.88
Comparative yearly lighting energy cost per 1000 lumens = $4.80
OPTIONS & ACCESSORIES
ACCESS PLATE: Top Wiring access plate is shipped with fixture as standard.
When access plates are required in advance for wiring convenience, specify sepa-
rately. Order Catalog Number: ACP CSP.
ELECTRICAL WIRING OPTIONS: Consult factory.
FUSING: Internal fast-blow fusing. SUFFIX: GLR.
Internal slow-blow fusing. SUFFIX: GMF.
RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture
standard. SUFFIX: RF.
CONTINUOUS ROW INSTALLATION: For F type fixtures, half-width flanges are
required between fixtures. Order Catalog Number: 1FCTRIM (each joint).
SPLAY TRIM: For T ceiling type only. SUFFIX: CTZ14 S2 SPLAY TRIM.
AIR CLOSURE STRIP: SUFFIX ACS4 (factory installed).
DRYWALL KIT: Order Catalog Number: FK91X4. Request Folio OA30-10.
CHICAGO PLENUM: SUFFIX: CP.
SPECIFICATIONS
PERFORMANCE: In an installation of 1 lamp 32W luminaires in a room cavity
ratio of 1, reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less
than .67 with a spacing to mounting ratio of 1.9 perpendicular to the lamps. To
meet IES RP-1 recommended (basic) requirements for VDT areas the VCP (visual
comfort probability) shall not be less than 91 either crosswise or lengthwise and
the maximum average brightness at 65°, 75° and 85° shall not exceed 837, 82 and
41 candelas per square meter respectively in the 0°, 45° and 90° horizontal planes.
Candelas at Nadir (0°) not to exceed 652.
SPECIFICATIONS (continued)
AIR HANDLING: (VRA only) side air passages for air supply or air return.
Optional side closure strips. Air return is also provided through the lamp com-
partment through fixture body ends.
MATERIALS: Chassis parts are die-formed embossed cold rolled steel.
Housing is embossed for rigidity with all edges turned-in for safe handling.
LOUVER: Pre-anodized aluminum (Coilzak@ or equal).
FINISH: Louver—low iridescence semi-specular anodized vertical grain alu-
minum reflector sheet is standard. Reflector—white baked polyester enamel
minimum 86% reflectance. Phosphate undercoating. Chassis exterior—black
baked polyester enamel.
ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°.
LABELS: I.B.E.W./UL and C-UL.