Lightolier V611 Indoor Furnishings User Manual


 
nuea I
Page 2 of 2
INSTALLATION OF PRE-WIRED CALCULITE FRAME-IN-KITS
A-LAMP WALL WASHER/DOWNLIGHT (Cent’d)
B. ADJUST MOUNTING FRAME
For both plaster or other dry ceiling installation,
MOUNTING FRAME must be set so that the
bottom edge is flush with the finished ceiling, as
shown on Fig. 6.
NOTE: 1. To insure proper installation, the MOUNTING FRAME
must always” be” secure to structural ceiling members.
2. Final vertical adjustment can be made by means of
MOUNTING BRACKET SCREWS (Fig. 2) on inside of
MOUNTING FRAME.
FIG.
6
c.
D.
ADJUST SOCKET HOUSING
Engage SPRING to SLOTS for desired lamp/wattage
position (see label on inside and outside of neck of
REFLECTOFUHOUSING as shown on Fig. 7).
ADJUSTABLE SOCKET
HOUSING
SLOT
NOTE: To remove REFLE(70R/HOUSING for
inspection and maintenance, push
RETAINING SPRINGS outward and detach
REFLECTOR/HOUSING from MOUNTING
FRAME (See Fig. 1).
To insure neat installation, do not remove
CARDBOARD PAINT SHIELD (provided) in
MOUNTING FRAME (Fig. 1). The SHIELD
will protect the inside of
/
REFLECTOR/HOUSING from paint, pIaster
and dust. Remove it only after construction
RETAINING
is completed.
SPRINGS
FIG. 7
CARE AND MAINTENANCE OF “Al-ZAK”
REFLECTOR
If handling of reflectors with anodized or Alzak
finish is required, the use of clean white or plastic
film gloves recommended to avoid fingerprints.
Anodized or Alzak surfaces can be cleaned by the
following methods:
1. Wipe off with a soft, clean, dry, lint-free cloth.
2. Wipe off with a soft clean cloth dampened in
mild detergent solution. Rinse, then wipe dry with
lint-free cloth or paper towel.
3. Wipe off with a clean cloth dampened with a
solution of wetting agent and water (such as 2
oz. per gallon “Pluronic L62-LF” by Wyandotte
Products) or a liquid wax such as Glass Wax@.
Then wipe dry. Avoid gritty cleaning agents.