Lightolier STA1G8LR132120SO Indoor Furnishings User Manual


 
STACKLYTE STA 1'x4' 1 LAMP
Page 2 of 2 1'x4' RECESSED FLUORESCENT, 3" DEEP, 8 OR 12 CELL PARABOLIC LOUVER
STATIC OR AIR SUPPLY/RETURN, IES RP1 FOR NORMAL VDT USE
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902 Section 2/Folio G40-14 REV. A
Job Information Type:
OPTIONS & ACCESSORIES
ACCESS PLATE: Top Wiring access plate is shipped with fixture as standard.
When access plates are required in advance for wiring convenience, specify sepa-
rately. Order Catalog Number: ACP CSP.
ELECTRICAL WIRING OPTIONS: Consult factory.
FUSING: Internal fast-blow fusing. SUFFIX: GLR.
Internal slow-blow fusing. SUFFIX: GMF.
RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per fixture
standard. SUFFIX: RF.
SPLAY TRIM: For T ceiling type only. SUFFIX: CTZ14 S2 SPLAY TRIM.
PLASTER FRAMES: F type fixtures do not include plaster frames. For individual
or continuous mounting, specify PF14 universal frame per fixture.
AIR CLOSURE STRIP: SUFFIX ACS4 (factory installed).
DRYWALL KIT: Order Catalog Number: FK91X4. Request Folio OA30-10.
CHICAGO PLENUM: SUFFIX: CP.
SPECIFICATIONS
PERFORMANCE: Luminaire distribution is to be a minimum of 97.5% in the 0°-
60° zone. In an installation of 1 lamp 32W luminaires in a room cavity ratio of 1,
reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .80
with a spacing to mounting ratio of 1.5 perpendicular to the lamps. To meet IES RP1
recommended (basic) requirements for VDT areas the VCP (visual comfort probabili-
ty) shall not be less than 90 either crosswise or lengthwise, and the maximum
PHOTOMETRY MODEL NO. STA1G8LR132120SO
coefficients of utilization — zonal cavity method
RF 20 20 20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
0878787 818181 787878
1828077 757372 727170
2777268 686563 666462
3716561 625956 605755
4665954 575249 555149
5625448 524744 504643
6574944 474339 464239
7544540 433935 433835
8504136 403532 393532
9473833 373229 363229
10 44 35 30 34 30 27 34 30 27
room cavity ratio
ORDERING INFORMATION
Explanation of Catalog Number. Example: STA1G8LR132120SOGLR
To meet NYC Code requirements prefix catalog number
with (N).
BLANK = Standard
N = NYC Code
ST
STACKLYTE:
3" Deep
Precision
Contoured
Pre-
anodized
Aluminum
Louver
BODY STYLE:
A=Air Handling
S=Static
1
FIXTURE
WIDTH
CEILING TYPE:
G=Grid (lay-in T bar)
F=Flanged (overlap)
Z spline and
plaster frame
T=Slot grid or
two-directional
concealed T
(see options)
NUMBER OF
CELLS:
8=1 row of
8 cells
12=1 row of
12 cells
LOUVER
FINISH:
L=Low
Iridescence
Semi-specular
(standard)
P=Low
iridescence
specular
R
REFLECTOR:
R=Specular
95%
Reflective
1
LAMP
QUANTITY
LAMP/
FIXTURE
LENGTH:
32=T8
34=T12
(Nominal 48")
VOLTAGE:
120 or 277
OPTIONS:
Add appropriate
suffix to catalog
no, ie: (GLR)
Meets IES RP-1 recommended (basic).
VERTICAL FOOTCANDLES ON BOOK SHELVES
Ceiling 1' 2' 3' 4'
1.00 48.3 48.4 48.5 48.4 48.3 48.4 48.5 48.4 48.3
2.00 36.4 36.0 36.2 36.3 36.4 36.3 36.2 36.0 36.4
3.00 28.3 28.3 28.3 28.3 28.3 28.3 28.3 28.3 28.3
4.00 23.6 23.5 23.6 23.5 23.6 23.5 23.6 23.5 23.6
5.00 21.0 20.9 21.0 20.9 21.0 20.9 21.0 20.9 21.0
6.00 18.3 18.3 18.3 18.3 18.3 18.3 18.3 18.3 18.3
7.00 16.4 16.4 16.4 16.4 16.4 16.4 16.4 16.4 16.4
8.00 15.6 15.6 15.6 15.6 15.6 15.6 15.6 15.6 15.6
9.00 14.7 14.6 14.6 14.6 14.6 14.6 14.6 14.6 14.6
10.00 13.5 13.5 13.5 13.5 13.4 13.5 13.5 13.5 13.5
11.00 11.9 11.9 11.9 11.9 11.9 11.9 11.9 11.9 11.9
12.00 9.9 9.8 9.9 9.8 9.8 9.8 9.9 9.8 9.9
0' 1' 2' 3' 4'
Book shelf aisle width, 36"
Floor
LER = FL - 60.2 IW - 30.4 BF - 0.88
Comparative yearly lighting energy cost per 1000 lumens = $3.97
BALLAST TYPE:
1 Lamp Mag. T12 LE
<20THD <10THD
1Lamp Elec. T8 SO* H
I*
LOL Dimming PS
*Instant Start Standard
Other dimming options. Consult factory.
SPECIFICATIONS (continued)
average brightness at 65°, 75° and 85° shall not exceed 334, 109 and 121 can-
delas per square meter respectively in the 0°, 45° and 90° horizontal planes.
AIR HANDLING: (STA only) side air passages for air supply or air return.
Optional side closure strips. Air return is also provided through the lamp com-
partment through fixture body ends.
MATERIALS: Chassis parts are die-formed embossed cold rolled steel.
Housing is embossed for rigidity with all edges turned-in for safe handling.
LOUVER: Pre-anodized aluminum (Coilzak® or equal).
FINISH: Louver—semi-specular low iridescence pre-anodized reflector sheet.
Reflector—95% reflective specular. Phosphate undercoating.
Chassis exterior—black baked polyester enamel.
ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB.
If K.O. is within 3" of ballast, use wire suitable for at least 90°.
LABELS: I.B.E.W./UL and C-UL.