Lightolier SQ6-4 Indoor Furnishings User Manual


 
Job Information Type:
"JSQPSU3PBE'BMM3JWFS."tt'BY
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt
Lighting Systems SQ6-4
1BHFPG2 Y4RVBSF5-BNQQFS'PPU4FDUJPO
&
48" (121.92cm)
4' 2" (127.00cm)
96" (243.84cm)
4-Foot
8-Foot
8' 2" (248.92cm)
96" (243.84cm)
12-Foot
16-Foot
96" (243.84cm)
96" (243.84cm)
24-Foot
16' 2" (492.76cm)
24' 2" (736.60cm)
96" (243.84cm)
96" (243.84cm)
96" (243.84cm)
48"
(121.92cm)
12' 2" (370.84cm)
Fixture Lengths & Mounting Locations
Mounting Accessories
Power Feed End Set:
3 Wire Cord: SQ6EC36
4 Wire Cord*: SQ6EC36X4
5 Wire Cord*: SQ6EC36X5
End Set Stem:
SQ6ES24
End Set Wall:
SQ6E
Cable Cord
Assembly:
3 WIre Cord: SQ6CC36
4 Wire Cord*: SQ6CC36X4
5 WIre Cord*: SQ6CC36X5
Intermediate Suspension
Stem:
SQ6S24
*Use for dimming or emergency battery packs.
*For wall mounting locations see specification sheet SQ6-8.
Intermediate Cable
Suspension:
SQ6C36
Ceiling Grid Kit:
CGK
Includes both standard 1"
Tee and Slot Tee Clip.
Order one for every non-
powered suspension point.
Ceiling Grid Kit Power:
CGKP
Includes the hardware
necessary to install a power
feed above a suspended ceiling.
96" (243.84cm)
20-Foot
20' - 2" (614.68cm)
96" (243.84cm)
48"
(121.92cm)
J-box and Flex not included.
Order one for every powered
suspension point.
Performance & Quick Calculators
1800
1350
900
450
0
10
20
30
40
50
60
70
80
909090
100
110
120
130
140
150
160
170
180
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
0797979737373 606060
1706764646259 535150
2615753565249 474442
3544945504541 423835
4484238443935 373330
5433733403430 332926
6383328363027 302623
7352925322723 272320
8322622292421 252118
9292320272219 231916
10 26 21 18 25 20 17 21 17 15
CANDLEPOWER
180 1446 1446 1446 1446 1446
175 1449 1441 1432 1425 1423
165 1402 1400 1420 1436 1442
155 1309 1330 1384 1431 1442
145 1168 1218 1312 1380 1394
135 987 1076 1195 1250 1257
125 764 903 1001 1048 1052
115 520 684 755 770 751
105 268 427 411 401 390
95 45 97 71 66 56
90 0 5 10 12 0
85 32 41 43 51 56
75 145 152 157 192 202
65 274 293 316 451 555
55 430 469 536 799 1010
45 664 753 845 1032 1175
35 994 1077 1151 1293 1390
25 1306 1383 1456 1547 1600
15 1585 1628 1686 1745 1769
5 1795 1804 1811 1811 1813
0 1822 1822 1822 1822 1822
ZONAL LUMEN SUMMARY
ZONE
LUMENS % BARELAMP % LUMINAIRE
0-90 3900 33.0 44.1
90-180 4953 42.0 55.9
0-180 8854 75.0 100.0
Report No: ITL53180
Catalog No.: SQ644BPS1
Lamps: 4-F32T8
Lumens: 2950
Efficiency: 79.0%
ROOM CAVITY RATIO
022456790
DEG.
ZONE
4-Foot Module 8-Foot Module
Cable/
Joiner
End Set
4-Foot Run 11
8-Foot Run 11
12-Foot Run 1111
16-Foot Run 211
20-Foot Run 1221
24-Foot Run 321