SPECPLUS SPS2GFSVA32U or 17
Page 2 of 2 2'x2' RECESSED FLUORESCENT, LENS FRAME TROFFER, STATIC
2 OR 3 LAMP, T8, 1-5/8" U LAMP OR 2' LAMP
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902 Section 1A/Folio E60-24
Job Information Type:
OPTIONS & ACCESSORIES
SPECIAL LENSES: Substitute VB for VA (standard) = .125" nominal pattern 12 with 7.8 oz.
average weight per square foot. Substitute VI for VA (standard) = .125" nominal pattern 12
with 6.8 oz. average weight per square foot.
PLASTER FRAME: Catalog Number PF22 .
CONTINUOUS ROW INSTALLATION: For F type fixtures, half width flanges are required
between fixtures. Order Catalog Number: S2FCTRIM (each joint).
RADIO INTERFERENCE FILTER 120 or 277 volt, 50 or 60 Hz. One per fixture is standard.
SUFFIX: RF.
FUSING: Internal fast-blow fusing.
SUFFIX: GLR.
Internal slow-blow fusing.
SUFFIX: GMF.
ELECTRICAL/WIRING OPTIONS: Consult factory.
DRYWALL KIT: Order Catalog Number: FK92X2.
Request Folio OA30-10.
CHICAGO PLENUM: SUFFIX: CP.
SPECIFICATIONS
PERFORMANCE: In an installation of 3 lamp 31W luminaires in a room cavity ratio of 1,
reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .72. To prevent
glare the VCP shall be not less than 35 either lengthwise or crosswise (at 100fc level), and the
average brightness at 65° shall not exceed 3497 candelas per square meter. To control veiling
reflections, luminaire output in the 30°-90° zone shall not be less than 66.8%.
SPECIFICATIONS (continued)
MATERIALS: Chassis parts are die-formed code gauge cold rolled steel. Housing with side
rails hemmed over and housing ends turned-in for safe handling.
FINISH: Chassis exterior—black baked polyester enamel. Cavity—white baked polyester
enamel minimum 86% reflectance. Phosphate undercoating.
LENSES: VA (standard) extruded virgin acrylic, 3/16" square based female cones, running
45° to the panel edge, .095" nominal thickness (similar to pattern 12). VB (optional) .125"
nominal pattern 12 with 7.8 oz. average weight per square foot. VI (optional) .125" nominal
pattern 12 with 6.8 oz. average weight per square foot.
ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is
within 3" of ballast, use wire suitable for at least 90°.
LABELS: I.B.E.W./UL and ULc Listed.
PHOTOMETRY MODEL NO. SPS2GFSVA32U or 17
coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)
RF 20 20 20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1757269 676563 656362
2696359 605754 585553
3635651 534946 524845
4585145 484440 464339
5544640 433935 423835
6504136 393531 383431
7463832 363128 353128
8433429 332825 322825
9403226 312623 302623
10 38 29 24 28 24 21 28 24 21
visual comfort probability (rated lumens per lamp 3150.)
room size ceiling height ceiling height
W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0
20 20 51 55 62 69 49 53 59 66
20 30 45 48 53 58 41 45 50 55
20 40 42 44 48 52 36 40 44 49
20 60 38 41 44 47 32 36 39 44
30 20 53 57 61 67 51 55 59 65
30 30 46 49 52 57 42 46 50 54
30 40 41 44 47 50 37 40 44 47
30 60 38 41 42 45 33 36 38 42
30 80 36 39 40 43 31 33 35 38
40 20 54 58 62 67 53 57 61 66
40 30 47 50 53 57 44 48 51 55
40 40 42 45 47 50 38 42 45 48
40 60 38 41 42 45 34 37 38 42
40 80 37 39 39 42 32 34 35 38
40 100 36 38 38 40 31 32 33 35
60 30 48 51 54 58 46 50 52 56
60 40 43 46 48 51 40 43 46 49
60 60 39 41 42 45 35 37 39 42
60 80 37 39 39 42 32 34 35 38
60 100 36 37 37 40 31 32 33 35
100 40 45 48 50 53 44 47 49 52
100 60 41 43 44 47 38 40 41 45
100 80 39 40 40 43 35 37 37 40
100 100 37 38 38 40 33 34 34 36
room cavity ratio
luminaries lengthwise
luminaries crosswise
ORDERING INFORMATION
Explanation of Catalog Number. Example: SPS2GFSVA32U120O3RF
SP
SPECPLUS:
Recessed
fluorescent
troffer
S
STATIC
2
FIXTURE
WIDTH
CEILING TYPE:
G=Grid (lay-in T bar)
F=Flanged (overlap) Z spline
and plaster frame
LENS FRAME:
FS=Flat steel frame
RA=Regressed
aluminum frame
FA=Flat aluminum frame
VA
LENS/SHIELDING TYPE:
VA (virgin acrylic)
standard (see options and
consult factory)
LAMP
QUANTITY:
2=2 Lamp
3=3 Lamp
LAMP/
FIXTURE LENGTH:
2U=T8, 1-5/8" U Lamp
17=T8, 2' Lamp
(Nominal 24")
VOLTAGE:
120 or 277
BALLAST TYPE:
<20THD <10THD
1 & 2 Lamp Elec. T8 SO* H
I*
1-3 Lamp Elec. T8 O3* H3*
LOL Dimming PS
*Instant Start Standard
OPTIONS:
Add appropriate suf-
fix to catalog no., ie:
(GLR)
Other dimming options. Consult factory.
Luminaire Efficacy Rating
LER-64.1 Watts-76.2 BF-0.88