Lightolier SL111B2 Indoor Furnishings User Manual


 
KUBIK 1.5 SL111B 2
Page 4 of 5 Louver Stand-Off Unit
Options and Accessories
Emergency Lighting: Electronic Bodine slim profile battery pack. The emergency
ballast senses the power failure and immediately switches to emergency mode
by illuminating the lamp at a reduced lumen output for a minimum of 90 mins. The
battery fully recharges within 24 hours. Add suffix (EM) to the catalogue numbers.
DALI Interface: Digital Addressable Lighting Interface available upon request
for individual luminaires. Ballast 120 volts or 277 volts only. Consult your
Lightolier representative.
Markings
cULus Listed. Suitable for damp locations.
Mounting
Direct Mount: No mounting directely are possible at the ceiling no to the wall.
Suspended Mount: Single stem or aircraft cable with round canopy suitable for
mounting one standard outlet box for plaster ceiling exposed installation or suspended
ceilings mounts. Stem and cable mounts can both be used on the same luminaire.
Patterns: Suitable for different patterns in continuous row mounting.
Electrical
Ballast: Electronic slim profile 1 lamp 28W T5 or 54W T5HO linear ballast.
U: Universal voltage ballast automatically detects 120V to 277V, 50 or 60Hz
operations.
1: 120V ballast only.
2: 277V ballast only.
H: 347V ballast only.
Lampholder: G5 plug-in base, miniature Bi-pin.
Finish
Natural brushed and anodized aluminum. All painted parts are
powder coat paint process.
ZONE
DEG
ALONG 22.5 45 67.5 ACROSS
0 454 454 454 454 454
5 452 454 455 454 452
15 414 421 441 454 461
25 347 364 408 450 465
35 269 300 368 441 473
45 177 224 327 433 483
55 79 145 283 420 491
65 24 72 238 379 433
75 10 32 156 257 307
85 0 16 100 213 277
90 0 14 94 203 265
95 0 16 100 213 277
105 10 32 156 257 307
115 24 72 238 379 433
125 79 145 283 420 491
135 177 224 327 433 483
145 269 300 368 441 473
155 347 364 408 450 465
165 414 421 441 454 461
175 452 454 455 454 452
180 454 454 454 454 454
COEFFICIENTS OF UTILIZATION
ZONAL CAVITY METHOD * EFFECTIVE FLOOR CAVITY REFLECTANCE = .20
80 70 50
Wall Reflectance
70 50 30 10 70 50 30 10 50 30 10
DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES
LUMINAIRE INPUT WATTS = 62.8
Room Cavity Ratio
ZONE LUMENS % LAMP % LUMINAIRE
0-30 354 6.82 11.01
0-40 585 11.27 18.21
0-60 1092 21.02 33.97
0-90 1608 30.94 50.00
40-90 1023 19.67 31.79
60-90 515 9.92 16.03
90-180 1608 30.94 50.00
0-180 3217 61.88 100.00
DISTRIBUTION
CANDLEPOWER CURVE
Performance
CANDLEPOWER
REPORT NO: CB903
CAT. NO: SL111B228PIUSPR
2 x 28W T5 at 2600 Lumens
Efficiency: 61.9 %
Candela at Nadir: 454cd
0°
90°90°
180°
300
600
900
0 .66 .66 .66 .66 .61 .61 .61 .61 .52 .52 .52
1 .60 .57 .54 .52 .55 .52 .50 .48 .44 .42 .41
2 .54 .49 .45 .41 .50 .45 .42 .39 .38 .35 .33
3 .49 .43 .38 .34 .45 .40 .36 .32 .34 .30 .28
4 .45 .38 .33 .29 .41 .35 .31 .27 .30 .26 .23
5 .41 .33 .28 .24 .37 .31 .26 .23 .26 .22 .20
6 .38 .30 .25 .21 .34 .28 .23 .19 .23 .20 .17
7 .35 .27 .21 .18 .32 .25 .20 .17 .21 .17 .15
8 .32 .24 .19 .15 .29 .22 .18 .14 .19 .15 .13
9 .29 .22 .17 .13 .27 .20 .16 .13 .17 .13 .11
10 .27 .20 .15 .12 .25 .18 .14 .11 .15 .12 .10
Job Information Type:
Lightolier www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2008 Philips Group • SL111B2.pdf
Canlyte www.canlyte.com
3015 Louis-Amos, Lachine, Québec H8T 1C4 • (514) 636-0670 • (514) 636-0460
Lightolier is a Philips group brand