Lightolier SKSGPK332 Indoor Furnishings User Manual


 
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 a Philips Group Section 5/Folio MA12-18
Job Information Type:
Lightolier is a Philips group brand
Skyway SKS2GPK232 or 332
Page 2 of 2 2' x 4' Recessed Fluorescent, Tri-Lens Frame
Static or Air Supply/Return, 2 or 3 Lamp T8
Ordering Information
Explanation of Catalog Number. Example: SKS2GPK232UNVHI
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: A.
Internal slow blow fusing: SUFFIX: C.
Drywall Kit: Order Catalog Number: FK92X4.
Electrical Wiring Options: Consult factory.
For motion or light sensor: See Folio OA20-10 and OA20-30.
Specifications
Performance: In an installation of 2 lamp 32W luminaires in a room cavity
ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not
be less than .80. To reduce glare the average brightness at 65° shall not exceed
1511 candelas per square meter. To control veiling reflections, luminaire output
in the 30°-90° zone shall not be less than 67.1%.
Air Handling: (SKA only) side air passages for air supply or air return. Supply
air is discharged vertically. Optional side closure strips. Air return is also provid-
ed through the lamp compartment through fixture body ends.
Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing
has
side rails hemmed over and housing ends turned-in for safe handling.
Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked
polyester enamel minimum 86% reflectance. Rust preventative undercoating.
Reflectors- 95% reflective white powder coated.
Specifications (continuned)
Lens: Proprietary high quailty frost white acrylic and clear conical prism lens assembly.
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of
ballast, use wire suitable for at least 90°.
UL Listed for damp locations.
Labels: I.B.E.W./UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal Laws.
See: www.lamprecycle.org
Options:
Add appropriate
suffix to catalog
no., ie: (A)
Skyway
Recessed
Fluorescent
Body Style:
S = Static
A = Air
2
Fixture
Width
Ceiling Type:
G = Standard
Grid
T = Slot Grid
P
Side Lens:
P= Frost White
Acrylic Lens
32
K
Center Lens:
K= Pattern 19
.156 Virgin
Acyrlic Lens
Lamp
Quantity
2=2 Lamp
3=3 Lamps
0.0 45.0 90.0 FLUX
0 1990 1990 1990
5 1972 1975 1978 188
15 1875 1891 1913 535
25 1702 1765 1831 815
35 1464 1589 1647 979
45 1156 114 1063 867
55 732 714 643 630
65 406 401 354 400
75 205 185 170 207
85 48 35 31 46
90 000
Model No. SKS2GPK232UNVC5
LER = FP - 69.3 IW - 51.9 BF - 0.77
Comparative yearly lighting energy cost per
1000 lumens = $3.46
Report Number: G2008169
Catalog Number: SKS2GPK232UNVC5
Lamps: (2) F32T8/ADV/841/ALTO
Luminaire: Skyway Recessed 2' x 4' fixture
prismatic acrylic lens assembly.
Ballast: INC-2P32-LW-SC
Report is based on 3100 Lumens per lamp.
Efficiency: 75.3%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.3
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 45.600 21.600
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 2572. 2478. 2365.
55 2008. 1958. 1764.
65 1511. 1493. 1318.
75 1246. 1124. 1033.
85 866. 632. 560.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01838077757371727069
02767066666360646158
03706357595551575450
04645650534844524744
05605144484339474239
06554639443834433834
07514235403531393431
08483832373128363128
09453529342925332825
10 42 33 27 31 26 23 31 26 23
ZONE LUMENS % LAMP % FIXT
00-030 1537 24.8 32.9
00-040 2516 40.6 53.9
00-060 4013 64.7 86.0
00-090 4666 75.3 100.0
90-180 0000 0.0 000.0
00-180 4666 75.3 100.0
ZONAL LUMEN SUMMARY
Voltage:
120, 277 or
UNV=120-277
0.0 45.0 90.0 FLUX
0 3104 3104 3104
5 3082 3082 3092 293
15 2940 2945 2951 831
25 2672 2662 2625 1222
35 2284 2184 2158 1382
45 1710 1657 1665 1284
55 1052 1099 990 955
65 608 639 565 626
75 323 296 284 333
85 90 74 66 88
90 15 16 8
Model No. SKS2GPK332UNVH3
LER = FP - 70.9 IW - 87.0 BF - 0.88
Comparative yearly lighting energy cost per
1000 lumens = $3.38
Report Number: G2008332
Catalog Number: SKS2GPK332UNVH3
Lamps: (3) F32T8/ADV/841/ALTO
Luminaire: Skyway Recessed 2' x 4' fixture
prismatic acrylic lens assembly.
Ballast: ICN-3P32-SC
Report is based on 3100 Lumens per lamp.
Efficiency: 75.4%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.3
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 45.600 21.600
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 3804. 3686. 3704.
55 2885. 3014. 2715.
65 2263. 2379. 2103.
75 1963. 1895. 1726.
85 1624. 1336. 1191.
LUMINANCE DATA IN CANDELA/SQ. METER
ZONE LUMENS % LAMP % FIXT
00-030 2346 25.2 33.5
00-040 3728 40.1 53.2
00-060 5967 64.2 85.1
00-090 7014 75.4 100.0
90-180 00000.0000.0
00-180 7014 75.4 100.0
ZONAL LUMEN SUMMARY
SK
Standard Skyway
SY
For NYC Code – I.B.E.W. Manufactured
NK
For NYC Code – Local 3 Manufactured
Lamp:
(By Others)
32=T8 32W
(Nominal 48")
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01838077757371727068
02767066666360646158
03706357595551575350
04645650534844514744
05605044484339474238
06554639443834423834
07514235403531393430
08483832373128363128
09453529342925332825
10 42 33 27 31 26 23 31 26 23
Ballast Type:
Ballast
<20THD <10THD Factor
1 or 2 Lamp Elec. T8 SO* H
I*0.88
1-3 Lamp Elec. T8 O3* H3* 0.88
Advance Optanium
1 or 2 Lamp Elec. T8 C5* 0.77
1 - 3 Lamp Elec. T8 C6* 0.77
LOL Dimming T8 PS*
*Instant Start Standard
Other dimming options. Consult factory.
NOTE:
For T8 UNV, you must use H
I
OR H3Ballast Code.