Lightolier SKS2GPK317 Indoor Furnishings User Manual


 
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 a Philips Group Section 5/Folio MA12-14
Job Information Type:
Lightolier is a Philips group brand
Skyway SKS2GPK217 or 317
Page 2 of 2 2' x 2' Recessed Fluorescent, Tri-Lens Frame
Static or Air Supply/Return, 2 or 3 Lamp T8
Ordering Information
Explanation of Catalog Number. Example: SKS2GPK217UNVHI
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: A.
Internal slow blow fusing: SUFFIX: C.
Drywall Kit: Order Catalog Number: FK92X2.
Electrical Wiring Options: Consult factory.
For motion or light sensor: See Folio OA20-10 and OA20-30.
Specifications
Performance: In an installation of 2 lamp 17W luminaires in a room cavity
ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not
be less than .75. To reduce glare the average brightness at 65° shall not exceed
1375 candelas per square meter. To control veiling reflections, luminaire output
in the 30°-90° zone shall not be less than 67.6%.
Air Handling: (SKA only) side air passages for air supply or air return. Supply
air is discharged vertically. Optional side closure strips. Air return is also provid-
ed through the lamp compartment through fixture body ends.
Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing
has
side rails hemmed over and housing ends turned-in for safe handling.
Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked
polyester enamel minimum 86% reflectance. Rust preventative undercoating.
Reflectors- 95% reflective white powder coated.
Specifications (continuned)
Lens: Proprietary high quailty frost white acrylic and clear conical prism lens assembly.
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of
ballast, use wire suitable for at least 90°.
UL Listed for damp locations.
Labels: I.B.E.W./UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal Laws.
See: www.lamprecycle.org
Options:
Add appropriate
suffix to catalog
no., ie: (A)
Skyway
Recessed
Fluorescent
Body Style:
S = Static
A = Air
2
Fixture
Width
Ceiling Type:
G = Standard
Grid
T = Slot Grid
P
Side Lens:
P= Frost White
Acrylic Lens
17
K
Center Lens:
K= Pattern 19
.156 Virgin
Acyrlic Lens
0.0 45.0 90.0 FLUX
0 845 845 845
5 839 838 839 80
15 796 797 801 225
25 714 727 752 337
35 602 648 695 405
45 459 477 474 367
55 297 308 287 270
65 171 175 162 175
75 89 86 79 94
85 21 24 17 26
90 773
Model No. SKS2GPK217UNVHI
LER = FP - 58.1 IW - 31.7 BF - 0.93
Comparative yearly lighting energy cost per
1000 lumens = $4.13
Report Number: G2008293
Catalog Number: SKS2GPK217UNVHI
Lamps: (2) F17T8/TL835/PLUS/ALTO
Luminaire: Skyway Recessed 2' x 2' fixture
prismatic acrylic lens assembly.
Ballast: ICN-2P32-SC
Report is based on 1400 Lumens per lamp.
Efficiency: 70.7%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.3
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 21.600 21.600
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 2156. 2240. 2226.
55 1720. 1783. 1662.
65 1344. 1375. 1273.
75 1142. 1103. 1014.
85 800. 914. 648.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01787572706866676664
02716661625956605754
03655953555148535047
04605247504541484441
05564741454036443936
06524337413632403532
07483933373229363228
08453630342926332926
09423327322723312623
10 39 30 25 29 25 21 29 24 21
ZONE LUMENS % LAMP % FIXT
00-030 642 22.9 32.4
00-040 1047 37.4 52.9
00-060 1684 60.1 85.1
00-090 1979 70.7 100.0
90-180 0000 0.0 000.0
00-180 1979 70.7 100.0
ZONAL LUMEN SUMMARY
Voltage:
120, 277 or
UNV=120-277
0.0 45.0 90.0 FLUX
0 1391 1391 1391
5 1384 1378 1381 131
15 1312 1309 1315 370
25 1175 1172 1166 539
35 984 952 956 602
45 720 714 732 553
55 447 475 435 412
65 260 274 249 269
75 140 131 125 145
85 33 35 28 39
90 12 13 5
Model No. SKS2GPK317UNVH3
LER = FP - 46.8 IW - 46.6 BF - 0.93
Comparative yearly lighting energy cost per
1000 lumens = $5.13
Report Number: G2008296
Catalog Number: SKS2GPK317UNVH3
Lamps: (3) F217T8.TL835/PLUS/ALTO
Luminaire: Skyway Recessed 2' x 2' fixture
prismatic acrylic lens assembly.
Ballast: ICN-3P32-SC
Report is based on 1400 Lumens per lamp.
Efficiency: 72.9%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.1
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 21.600 21.600
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 3382. 3353. 3438.
55 2588. 2750. 2519.
65 2043. 2153. 1957.
75 1796. 1681. 1604.
85 1257. 1334. 1067.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01807774727068696866
02746864646158625956
03686155575349555249
04625448514743504642
05584943474238454137
06534438423733413733
07504034393430383330
08463731363127353027
09443429332824322824
10 41 32 26 31 26 22 30 25 22
ZONE LUMENS % LAMP % FIXT
00-030 1040 24.8 34.0
00-040 1642 39.1 53.7
00-060 2607 62.1 85.2
00-090 3060 72.9 100.0
90-180 00000.0000.0
00-180 3060 72.9 100.0
ZONAL LUMEN SUMMARY
SK
Standard Skyway
SY
For NYC Code – I.B.E.W. Manufactured
NK
For NYC Code – Local 3 Manufactured
Lamp:
(By Others)
17 =T8 17W
(Nominal 24")
Lamp
Quantity
2=2 Lamp
3=3 Lamp
Ballast Type:
Ballast
<20THD <10THD Factor
1 or 2 Lamp Elec. T8 SO* H
I* 0.88
1-3 Lamp Elec. T8 O3* H3* 0.88
Advance Optanium
1 or 2 Lamp Elec. T8 C5* 0.80
1 - 3 Lamp Elec. T8 C6* 0.81
LOL Dimming T8 PS*
*Instant Start Standard
Other dimming options. Consult factory.
NOTE:
For T8 UNV, you must use H
I
OR H3Ballast Code.