Lightolier SC4WC232 Indoor Furnishings User Manual


 
SC Cleanlite Enclosed Industrial Fluorescent SC4WC232
Page 2 of 2 Wet Locations, 1 or 2 Lamp T8
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
Copyright 2002 Lightolier Section7/Folio Q30-22 REV. B
Job Information Type:
Ordering Information
Explanation of Catalog Number. Example: SC4WC232120SOTP
Options/Accessories
Tamperproof Latches: Suffix: TP
Optional Lenses: Lexan lenses or DR acrylic lens. Consult factory.
Water Tight Kits: All fixtures are furnished with one watertight hub kit for top
or end conduit entry. Additional water tight kits required for every entry. Catalog
Number: GWHB CSP. For coupling kits required for continuous row mounting.
Catalog Number: KWCP CSP
Specifications
Materials: Chassis shall be 20 gauge steel.
Wireway Cover: Full length retained by fasteners for quick removal and
convenient servicing.
Lens: One-piece flanged lens enclosure molded from .125" thick smooth water-
clear virgin acrylic. Lens enclosure shall be heavy-duty vapor tight enclosed and
gasketed with closed-cell foam gasketing (permanently attached to fixture
housing).
Latches: Lock-tight cam action.
Finish: Chassis shall be phosphate primed and finished in baked white acrylic
enamel for not less than 86% reflectivity.
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and ULc Listed.
Photometry Model No. SC4WC232120SO
REPORT NUMBER: G92060 DATE: 7/2/02
CATALOG NUMBER: SCC232120SO
LAMP(S): 2 F32T8, EACH RATED 2850 LUMENS.
LUMINAIRE: 4 FT ENCLOSED INDUSTRIAL
TRIAD B432I120RH-A
CANDELA DISTRIBUTION
0.0 22.5 45.0 67.5 90.0
0 1032 1032 1032 1032 1032
5 1022 1027 1034 1042 1047
15.0 979 1000 1020 1043 1057
25.0 899 934 992 1046 1068
35.0 785 839 940 1028 1058
45.0 642 725 870 1015 1070
55.0 473 586 818 945 983
65.0 290 462 667 773 806
75.0 124 312 493 616 653
85.0 27 162 311 421 458
90.0 12 105 231 333 367
ZONAL LUMEN SUMMARY
ZONE LUMENS % LAMP % FIXT
0-30 846 15 19
0-40 1431 25 32
0-60 2792 49 62
0-90 4170 73 92
90-180 350 6 8
0-180 4520 79 100
TOTAL LUMINAIRE EFFICIENCY = 79.0%
CIE TYPE – DIRECT
PLANE: 0-DEG 90-DEG
SPACING CRITERIA; 1.21 1.56
SHIELDING ANGLES: 90 90
PLANE: 0-DEG 90-DEG
LUMINOUS LENGTH: 46.000 8.156
LUMINANCE DATA IN CANDELA/SQ M
ANGLE AVERAGE AVERAGE AVERAGE
IN DEG 0-DEG 45-DEG 90-DEG
45 4256 4473 5156
55 3770 4644 5139
65 3020 4376 4769
75 1939 3978 4608
85 903 3389 4159
90°
75°
60°
45°
30°
15°
0
268
535
803
1070
LEGEND;
0-deg
45-deg
90-deg
G92060 7/2/02
SC4WC232120SO
2 F32T8, EACH RATED 2850 LUMENS
4 FT ENCLOSED INDUSTRIAL
TRIAD B2321120RH-A
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.
coefficients of utilization — zonal cavity method
RF 20 20 20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1807571 716865 676462
2716458 605651 575349
3645649 524742 494440
4584942 464035 433834
5534336 413430 393329
6493931 373026 352925
7453528 332722 312622
8423225 302420 292319
9392922 282218 262117
10 37 27 20 25 20 16 24 19 16
room cavity ratio
SC
Cleanlite:
Industrial
Fluorescent for
Wet Locations
Number of
Lamps in
Width:
1 or 2 Lamps
32
Lamp/Watts
(By others)
32 = 32w T8
(Nominal 48")
Voltage:
120 or 277
Options:
Add appropriate
suffix to catalog
no, ie: (TP)
Ballast:
<20THD <10THD
1 & 2 Lamp Elec. (T8) SO* H
I*
*Instant Start Standard
4
Fixture
Length
4 = 4' Length
W
Location:
W =Wet Locations
C
Lens:
C = Clear Lens
†No Product Change. New Catalog Number Designation.
WATER TIGHT HUB KIT Cat. No. GWHB CSP
Universal waterproof
fitting for conduit
entrance or stem mounting
Rubber
gasket
Knockout
Weatherproof
fitting
Housing end
or top
COUPLING KIT Cat. No. KWCP CSP
Housing End
Housing
End
Knockout
Knockout
Threaded
coupling
Rubber Gasket
Lock
nut
Lock
nut