Lighting Systems RT6-11
1BHFPG -ZUFUVCF*OEJSFDU-JHIU51FS'PPU4FDUJPO
Performance
90˚
85˚
95˚
105˚
75˚
65˚
55˚
115˚
125˚
180˚ 175˚ 165˚ 155˚ 145˚ 135˚
0˚ 5˚ 15˚ 25˚ 35˚ 45˚
600
400
800
200
1000
0
REPORT NO: LRL 489-10G
LAMPS: 1-32WT8
LUMENS: 2900
EFFICIENCY: 76.7%
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
% WALL REFLECTANCE
50 30 10 50 30 10 50 30 10
073 737362 6262 43 4343
163 615854 5250 37 3635
255 514847 4441 32 3029
349 433942 3734 29 2624
443 373337 3229 25 2220
538 322832 2824 22 1917
6 33 28 24 29 24 21 20 17 15
730 242026 2118 18 1513
827 211823 1915 16 1311
924 191521 1714 15 1210
10 22 17 14 19 15 12 13 10 9
20% FLOOR CAVITY REFLECTANCE
ROOM CAVITY RATIO
CANDLEPOWER CURVE
Mounting & Joiner Block Accessories
"L" Joiner Block
RT62-LI
Power Feed End
RT65E
3" 3"
6"
6"
9"
9"
Inline Joiner Block
RT62-ILI
6"
12"
6"
ZONAL LUMEN SUMMARY
ZONE LUMENS % BARELAMP % LUMINAIRE
0-90 0 0.0 0.0
90-180 2224 76.7 100.0
0-180 2224 76.7 100.0
CANDLEPOWER
180 467 467 467 467 467
175 522 507 468 445 444
165 714 625 458 446 468
155 955 779 428 466 462
145 1047 894 374 399 381
135 946 858 300 310 316
125 795 715 235 239 261
115 669 568 151 180 159
105 359 356 71 84 93
95 31 52 15 7 7
9000000
8500000
7500000
6500000
5500000
4500000
3500000
2500000
1500000
500000
000000
Sample Run
4-FOOT JOINER
8-FOOT JOINER
96" (243.84cm)
48" (121.92cm)
Dimensions given are both fixture length and mounting distances.
42"
(106.68cm)
42"
(106.68cm)
42"
(106.68cm)
20'-6" (624.84cm)
42"
(106.68cm)
36"
(91.44cm)
4-FOOT MODULE
8-FOOT MODULE
8-FOOT MODULE
3" (7.62cm) END SET
3" (7.62cm) END SET
9" (22.86cm)
Ordering Instructions
Individual Fixtures:
1. Order number of JOINER FIXTURES.
2. Order one END SET CEILING ACCENT per fixture.
Square/Rectangle Patterns:
1. Order appropriate number of JOINER FIXTURES to complete the pattern size.
2. Order number and type of JOINER BLOCKS required.
3. Order one END SET CEILING ACCENT for each run.
Continuous Rows:
1. Determine run length.
2. Order the appropriate number of FIXTURES for the complete run. Fixtures can
be bolted together and through wired to complete long runs.
3. Order one END SET CEILING ACCENT for each run.
3” (7.62cm) 6“ (15.24cm) 9" (22.86cm) 12” (30.54cm)
9" (22.86cm) 12" (30.54cm) 12" (30.54cm)
ZONE
Deg.
022456790