Performance & Quick Calculators
85˚
75˚
65˚
45˚
55˚
0˚ 5˚ 15˚ 25˚ 35˚
600
750
450
900
050
300
0 deg
90
deg
180
deg
CANDLEPOWER CURVE
REPORT NO: LRL 499-5D
LAMPS: 1-FO32T8
EFFICIENCY: 46.7%
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY REFLECTANCE
80 70 50
50 30 10 50 30 10 50 30 10
0565656 545454 525252
1504947 494846 474645
2454341 444240 434139
3413835 403735 393634
4373431 363331 353330
5333027 333027 322927
6302724 302724 292624
7282421 272421 272421
8252119 252119 242119
9231917 221917 221917
10 21 17 15 21 17 15 20 17 15
CANDLEPOWER SUMMARY
ZONE
Deg
0 45 90 135 180
18000000
17500000
16500000
15500000
14500000
13500000
12500000
11500000
10500000
95 00000
90 00000
85 39 15 2 2 2
75 153 90 5 3 3
65 440 120 13 8 9
55 560 338 79 34 14
45 669 532 288 64 32
35 754 705 512 103 55
25 885 833 677 225 104
15 969 949 778 386 285
5 950 920 837 704 620
0 833 833 833 833 833
ZONE LUMENS % BARELAMP % LUMINAIRE
0-90 1354 46.7 100.0
90-180 0 0.0 0.0
0-180 1354 46.7 100.0
Quick Calculators
ONE SIDE MOUNTING
NO OPPOSITE WALL
1.5 63
2.5 33
3.5 22
4.518765133231815
5.5 16
6.5 15
7.514514535282319
8.5 12
9.512403833272320
024681012
DISTANCE FROM WALL, FEET
TWO SIDE MOUNTING
12 FT BETWEEN WALLS
1.5 76 76
2.5 50 50
3.5 41 41
4.5 38 92 73 65 73 92 38
5.5 37 37
6.5 35 35
7.5 34 72 71 69 71 72 34
8.5 33 33
9.5 32 63 66 65 66 63 32
024681012
DISTANCE FROM WALL, FEET
ONE SIDE MOUNTING
6 FT BETWEEN WALLS
1.5 72 39
2.5 43 45
3.5 33 45
4.5 28 85 68 43
5.5 26 40
6.5 24 37
7.5 22 60 55 33
8.5 21 30
9.5 19 49 48 28
0246
DISTANCE FROM WALL, FEET
HORIZONTAL FC
VERTICAL FC
DISTANCE FROM CEILING, FT
NOTE: Add to end of catalog number for desired ballast.
Blank = T12 Magnetic 120v
2 =T12 Magnetic 277v
E1 = T12 Electronic 120v
E2 = T12 Electronic 227v
E81 = T8 Electronic 120v
E82 = T8 Electronic 227v
M71 = T8 Electronic Dimming Ballast 120v
M72 = T8 Electronic Dimming Ballast 277v
Ordering Instructions
Individual Fixtures:
1. Order number of FIXTURES.
2. Order one END PLATE SET per fixture.
Continuous Rows:
1. Determine run length.
2. Use chart above to find catalog numbers. Each run ends with a telescoping unit.
3. Order END PLATE SET for each open run.
Square/Rectangle Patterns:
1. Consult plans and mark locations for corners.
2. Calculate net footage of each run.
3. Deduct corner dimension from each corner.
4. Determine catalog numbers the same way as a straight run.
Cat No. PTS7T148 PTS7184 PTS7160 PTS7148 PTS7136 PTS7124
Size 27" to 48" 84" 60" 48" 36" 24"
Lamps 1-4 Foot 2-4 Foot 2-3 Foot 1-4 Foot 1-3 Foot 1-2 Foot
Type Tele Module Module Module Module Module
4 '3"-6'0" 1 1
5'3"-7'0" 1
6'3"-8'0" 1
7'3"-9'0" 1
8'3"-10'0" 1 1
1
1
9'3"-11'0" 1 1
10'3"-12'0" 1 1
1
11'3"-13'0" 1
12'3"-14'0" 1 1 1
13'3"-15'0" 1 1 1
14'3"-16'0" 1
1
1
15'3"-17'0" 1 1 1
16'3"-18'0" 1 2
17'3"-19'0" 1 1 1
18'3"-20'0" 1 2 1
19'3"-21'0" 1 2 1
1
20'3"-22'0" 1 2 1
21'3"-23'0" 1 2 1
22'3"-24'0" 1 2 1
23'3"-25'0" 1 3
24'3"-26'0" 1 2 1
25'3"-27'0" 1 3 1
1
1
26'3"-28'0" 1 3 1
1
27'3"-29'0" 1 3 1
28'3"-30'0" 1 3 1
29'3"-31'0" 1 3 1
30'3"-32'0" 1 4
31'3"-33'0" 1 3 1
32'3"-34'0" 1 4 1
1
33'3"-35'0" 1 4 1
1
34'3"-36'0" 1 4 1
35'3"-37'0" 1 4 1
36'3"-38'0" 1 4 1
37'3"-39'0" 1 5
38'3"-40'0" 1 4 1
39'3"-41'0" 1 5 1
40'3"-42'0" 1 5 1
1
41'3"-43'0" 1 5 1
42'3"-44'0" 1 5 1
43'3"-45'0" 1 5 1
44'3"-46'0" 1 6
45'3"-47'0" 1 5 1
46'3"-48'0" 1 6 1
1
47'3"-49'0" 1 6 1
1
48'3"-50'0" 1 6 1
49'3"-51'0" 1 6 1
50'3"-52'0" 1 6 1
1
51'3"-53'0" 1 7
52'3"-54'0" 1 6 1
1
1
11
11
Ordering Information
ONE LIGHT
180
deg
0 deg
90
deg
% WALL REFLECTANCE
ROOM CAVITY RATIO
ZONAL LUMEN SUMMARY