Lightolier PLA2G9LP3FT Indoor Furnishings User Manual


 
Paralyte 2424 PLA2G9LP3FT
Page 2 of 2 2' x 2' Recessed Fluorescent, 3-1/8" Deep, 9 Cell Parabolic Louver
Static and Air Return 3 Lamp, Twin Tube T5
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2003 Genlyte Thomas Group LLC (Lightolier Division)
A0902 Section 2/Folio G50-54 Rev. A
Job Information Type:
Options & Accessories
Prewiring: 3/8” factory prewired cable (three no. 18 AWG leads, 6’ long),
Suffix: FF6, (Four no. 18 AWG leads, 6’ long), Suffix: FF14.
Fusing: Internal fast-blow fusing. Suffix: GLR.
Internal slow-blow fusing. Suffix: GMF.
Fluorescent Emergency Lighting System: Factory-installed emergency
power battery pack with charger and inverter, concealed in fixture channel.
Operates one fluorescent lamp at reduced light output for 90 minutes.
Suffix: EM.
Radio Intererference Filter: 120 or 277 volt, 50 or 60 Hz.
One per fixture. Suffix: R. One per ballast. Suffix: B.
Electrical Options: Special wiring, fusing or dimming ballasts and installed
lamps are available, consult your Lightolier representative or factory.
T-Bar Spacer: If T-bar is less than 1-1/2” deep, order Catalog Number: STC.
2 each end is required.
Specifications
Performance: In an installation of 3 lamp 40W Iuminaires in a room cavity
ratio of 1, with reflectance of 80% ceiling, 50% wall, 20% floor, the C.U shall
not be less than 78. To prevent glare the VCP shall not be less than 74 either
lengthwise or crosswise (at 100fc level) and the average brightness at 65°
shall not exceed 1340 foot-Iamberts. To control veiling reflections, luminaire
output in the 3C°-90° zone shall not be less than 72.1%.
Photometry Model No. PLA2G9LP3FT120X3
PL
Paralyte
2448:
3-1/8" Deep
Parabolic
Precision
Contoured
Pre-anodized
Aluminum
Louver
A 2
Fixture
Width
G
Ceiling Type:
G=Grid (lay-in T bar)
9
Louver Finish:
L = Low Iridescence
Semi-Specular (standard)
W = White Paint
3
Lamp
Quantity
FT
Lamp/
Fixture Length:
Twin Tube T5
(Nominal 24")
Voltage:
120 or 277
Ballast Type:
<20THD <10THD
1&2 Lamp Elec. TT5 SB*
IB*
(40 Watt)
1–3 Lamp Elec. TT5 X3*
I3*
(40 Watt)
LOL TT5 Dimming PB*
*Instant Start Standard
Options:
Add appropriate
suffix to catalog
no., ie: (GLR)
Other dimming options. Consult factory.
Number of
Cells
P
Ballast Cover
P
=
Dual V Reflector
coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)
RF 20 20 20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1817876 737270 716968
2757066 676461 646260
3696358 605653 585552
4645751 545046 524945
5595145 484440 474340
6544539 433834 423834
7494034 383329 373329
8463630 352926 342926
9423227 312623 312623
10 39 29 23 28 23 19 27 23 19
visual comfort probability (rated lumens per lamp 3150.)
room size ceiling height ceiling height
W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0
20 20 57 51 51 66 58 51 48 54
20 30 61 55 49 50 61 55 48 48
20 40 64 59 53 52 64 58 52 49
20 60 66 61 57 55 66 61 56 52
30 20 63 56 52 61 64 56 50 53
30 30 66 59 50 47 66 59 49 47
30 40 68 62 54 49 68 61 53 48
30 60 69 64 58 52 70 64 56 51
30 80 71 66 60 56 71 65 59 54
40 20 67 61 56 61 68 61 54 54
40 30 70 64 54 48 70 63 53 48
40 40 71 66 57 50 72 65 57 49
40 60 72 68 60 53 73 67 59 52
40 80 73 69 63 56 74 68 62 55
40 100 75 70 65 59 75 70 64 57
60 30 72 66 58 51 72 66 57 50
60 40 73 68 61 53 73 68 60 51
60 60 74 69 63 55 74 69 62 54
60 80 74 70 65 58 75 70 64 57
60 100 76 71 66 60 76 71 66 59
100 40 75 71 65 58 75 70 63 57
100 60 76 72 66 60 76 71 65 59
100 80 76 72 68 62 77 72 67 61
100 100 77 73 69 64 78 73 68 62
room cavity ratio
luminaries lengthwise
luminaries crosswise
LER=FP-61.9 IW - 97.9 BF - 0.88
Comparative yearly lighting energy cost per 1000 lumens=$3.88
ITL33751
LIGHTOLIER
PLA2G9LP3FT120X3
Ordering Information
Explanation of Catalog Number. Example: PLA2G9LP3FT120X3GLR
Body Style:
A
=
Air Handling
/Static
Specifications (continued)
Air Return: Designed to provide optimum air return. Air is returned through the
lamp compartment for all ceiling systems and direct to plenum through slots in
slot grid and narrow grid ceiling systems.
Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing
is embossed for rigidity with all edges turned up for safe handling. Louver is
pre-anodized aluminum (Coilzak or equal). rails hemmed over and housing ends
turned-in for safe handling.
Finish: Louver–semi-specular anodized low iridescence, vertical grain reflector
sheet. Cavity–white baked polyester minimum 86% reflectance. Phosphate
undercoating. Chassis exterior–black baked polyester enamel.
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If
K.O. is within 3” of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and ULc Listed.