Lightolier PLA2G12LS232 Indoor Furnishings User Manual


 
Paralyte 2448 PLA2G12LS232
Page 2 of 2 2' x 4' Recessed Fluorescent, 3-1/8" Deep, 12 Cell Parabolic Louver
Static and Air Return 2 Lamp, T8 or T12
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2003 Genlyte Thomas Group LLC (Lightolier Division)
A0902 Section 2/Folio G50-62 Rev. A
Job Information Type:
Options & Accessories
Prewiring: 3/8” factory prewired cable (three no. 18 AWG leads, 6’ long),
Suffix: FF6, (Four no. 18 AWG leads, 6’ long), Suffix: FF14.
Fusing: Internal fast-blow fusing. Suffix: GLR.
Internal slow-blow fusing. Suffix: GMF.
Fluorescent Emergency Lighting System: Factory-installed emergency power
battery pack with charger and inverter, concealed in fixture channel. Operates one
fluorescent lamp at reduced light output for 90 minutes. Suffix: EM.
Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz.
One per fixture. Suffix: R. One per ballast. Suffix: B.
Electrical Options: Special wiring, fusing or dimming ballasts and installed
lamps are available, consult your Lightolier representative or factory.
T-Bar Spacer: If T-bar is less than 1-1/2” deep, order Catalog Number: STC.
2 each end is required.
Specifications
Performance: In an installation of 2 lamp 32W Iuminaires in a room cavity ratio
of 1, with reflectance of 80% ceiling, 50% wall, 20% floor, the C.U shall not be
less than 84. To prevent glare the VCP shall not be less than 86 either lengthwise
or crosswise (at 100fc level) and the average brightness at 65° shall not exceed
1347 foot-Iamberts. To control veiling reflections, luminaire output in the 3C°-90°
zone shall not be less than 72.1%.
Specifications (continued)
Air Return: Designed to provide optimum air return. Air is returned through the
lamp compartment for all ceiling systems and direct to plenum through slots in
slot grid and narrow grid ceiling systems.
Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing
is embossed for rigidity with all edges turned up for safe handling. Louver is
pre-anodized aluminum (Coilzak
®
or equal).
Finish: Louver–semi-specular anodized low iridescence, vertical grain reflector
sheet. Cavity–white baked polyester minimum 86% reflectance. Phosphate
undercoating. Chassis exterior–black baked polyester enamel.
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If
K.O. is within 3” of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and ULc Listed.
Photometry Model No. PLA2G12LS232120SO
PL
Paralyte
2448:
3-1/8" Deep
Parabolic
Precision
Contoured
Pre-anodized
Aluminum
Louver
A 2
Fixture
Width
G
Ceiling Type:
G=Grid (lay-in T bar)
12
Louver Finish:
L = Low Iridescence
Semi-Specular (standard)
W = White Paint
Lamp
Quantity:
2 or 4 Lamps
Lamp/
Fixture Length:
32=T8
34=T12
(Nominal 48")
Voltage:
120 or 277
Ballast Type:
1–2 Lamp Mag. T12 LE
<20THD <10THD
1–2 Lamp Elec. T8 SO* H
I*
2–2 Lamp Elec. T8 SO* H
I*
1–4 Lamp Elec. T8 O4* H4*
LOL T8 Dimming PS*
Options:
Add appropriate suf-
fix to catalog no.,
ie: (GLR)
Other dimming options. Consult factory.
Number of
Cells
S
Ballast Cover
S=Single V Reflector
coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)
RF 20 20 20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1878481 797775 767473
2807470 706663 686562
3736660 625854 605653
4675852 555046 544945
5625245 504440 484339
6574740 453935 433834
7534235 403530 393430
8493832 373127 363127
9463529 342824 332824
10 43 32 26 31 26 22 30 25 22
visual comfort probability (rated lumens per lamp 3150.)
room size ceiling height ceiling height
W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0
20 20 76 72 72 83 73 66 66 73
20 30 79 75 73 73 76 69 66 69
20 40 82 78 76 75 79 72 69 68
20 60 83 80 78 77 81 75 72 71
30 20 80 76 72 79 78 71 68 73
30 30 83 79 73 70 81 74 67 68
30 40 84 81 76 72 82 76 70 67
30 60 86 82 78 75 84 78 73 70
30 80 87 83 80 77 85 80 75 72
40 20 83 79 75 78 80 75 72 73
40 30 85 81 75 71 82 77 71 69
40 40 86 83 78 72 84 79 73 68
40 60 87 84 80 75 85 81 75 71
40 80 88 85 81 77 86 82 77 73
40 100 88 85 82 78 86 82 79 75
60 30 85 83 78 73 83 78 73 72
60 40 87 84 80 74 85 80 75 71
60 60 88 85 81 76 86 82 77 73
60 80 89 86 83 78 87 83 79 75
60 100 89 86 83 79 87 83 80 76
100 40 87 84 81 77 85 80 77 72
100 60 88 85 83 79 86 82 79 74
100 80 88 86 84 80 87 84 80 77
100 100 89 87 84 81 87 84 82 78
room cavity ratio
luminaries lengthwise
luminaries crosswise
LER=FP-67.5 IW - 58 BF - 0.87
Comparative yearly lighting energy cost per 1000 lumens=$3.56
G91070
PLA2G12LS232120SO
Body Style:
A
=
Air Handling
/Static
Ordering Information
Explanation of Catalog Number. Example: PLA2G12LS232120SOGLR