Lightolier Mini-Beam Luminaires Indoor Furnishings User Manual


 
Lighting Layouts Mini-Beam Luminaires
Page 2 of 2
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
Copyright 2004 Lightolier Section5/Folio M30-10
Fixture: MBS2GPW154120PG (2'x4')
Quantity: 2 Rows of 2 Fixtures
Efficiency: 78.9%
Room Size: 15'x15'x9'
Reflectance: 80 Ceiling
50 Wall
20 Floor
Light Loss Factor: 0.93*
Lumens T5 Lamp: 4400**
Ballast Factor: 1.02
Average Maint. fc: 49
Watts/Square Foot: 1.1
Average Maintained fc:
30" High Work Surface
15' x 15' x 9' Office
Fixture: MBS2GPW154120PG (2'x4')
Quantity: 4 Rows of 4 Fixtures
Efficiency: 78%
Room Size: 30'x30'x9'
Reflectance: 80 Ceiling
50 Wall
20 Floor
Light Loss Factor: 0.93*
Lumens T5 Lamp: 4400**
Ballast Factor: 1.02
Average Maint. fc: 56.3
Watts/Square Foot: 1.1
Average Maintained fc:
30" High Work Surface
30' x 30' x 9' Office
*Light Loss Factor
Ballast Maintenance Light Loss
Typical T8 Fixture 0.89 x 0.92 = 0.82
1 Lite T5 Fixture 1.02 x 0.92 + 0.93
** Lumens At 25˚c
*Light Loss Factor
Ballast Maintenance Light Loss
Typical T8 Fixture 0.89 x 0.92 = 0.82
1 Lite T5 Fixture 1.02 x 0.92 + 0.93
** Lumens At 25˚c
15'
15'
50 48 48 50
49 49 49 49
49 49 49 49
50 48 48 50
3' 9' 15' 20' 26'
27'
21'
15'
9'
3'
30'
30'
56 56 54 57 56
57 57 56 59 57
55 56 55 57 55
57 57 56 59 57
56 56 54 58 56
12'
9'
6'
3'
3' 6' 9' 12’