Lightolier MDCGWSVA2SB4SB Indoor Furnishings User Manual


 
MD
*
Coffer 2' x 4' Recessed or Surface MDCGWSVA2SB4SB
Page 4 of 4 Multi-Function Patient Lighting
Indirect Ambient Light with Perforated Mesh Shield
Job Information Type:
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2007 a Genlyte company
Section 8/Folio R40-21 Rev. A
ORDERING INFORMATION
Explanation of Catalog Number. Example: MDCGWSVA2SB4SB120SW
MDC
MD*C
Indirect/
Direct
Recessed or
Surface,
Multi-function
Patient Light
with Perforated
Mesh Shield
G
Ceiling
Type:
Same Unit
May Be Used
For: Grid (lay-in)
Or: Surface
Mounted
2
Lamp
Quantity:
(Ambient/
Reading)
2 Lamps
(Total)
Specifications:
Materials: Chassis parts are die-formed 20 gauge steel. Louver (examination
light) – aluminum post painted white acrylic.
Reading light low iridescence anodized 95% reflective, semi-specular
reflector.
Ambient light flat white acrylic contoured steel reflector and perforated
steel mesh shield with white acrylic overlay.
Finish: Cavity (examination/reading/ambient lights) — flat white acrylic
interior, minimum reflectance 86%. Phosphate undercoating. Chassis
exterior post painted white baked polyester powder. Louver (examination
light) W=flat white baked enamel 36 cell louver with a virgin acrylic overlay to
enclose all lamps. VA=.095" nominal thickness prismatic virgin acrylic overlay.
VI=.125" nominal thickness, pattern 12 acrylic lens.
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°.
Specifications (continued):
Labels: I.B.E.W. UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with
Disposal Laws. See: www.lamprecycle.org
Options/Accessories
Access Plates: Top wiring access plate is shipped with fixture as standard.
When access plates are required in advance for wiring convenience, specify
separately. Catalog Number: ACP.
Drywall Kit: Order Catalog Number: FK92X4.
Request Folio OA30-10 Rev. A.
Electronic Sequential Switch (Low Voltage): Switch factory mounted in fix-
ture for ambient and reading light convenience (controlled by pillow switch, by
others). Suffix: SW.
Individual Switching (Low Voltage): Switches mounted to patient's bed for
use with manufacturer's control system (such as Hill-Rom Side Com).
Suffix: DP.
9/7 Watt Night Light: Suffix: PL (Lamp not included).
Fusing: Internal fast-blow fusing. Suffix: GLR.
Internal slow-blow fusing. Suffix: GMF.
Radio Interference Filter:
To order one RIF per fixture; Suffix: R. To order one RIF
per ballast; Suffix: B.
Germ Shield. Order Catalog Number: MD4CLGS24.
Electrical/Wiring Options: Consult factory
.
Louver
Overlay/Lens:
VA = Virgin Acrylic
.095" Nominal
Thickness
Overlay
(standard)
V
I = .125" Thick
Pattern 12
Acrylic Lens.
Ballast Type:
(Ambient Reading)
<20THD <10THD
1-2 Lamp Elec. TT5 SB* IB**
(40 Watt)
1-2 Lamp Elec. TT5
PR**
(40 Watt)
LOL Dimming TT5 PB
**Instant Start Standard
**Program Start
NOTE:
For TT5 UNV, you must use IB Ballast
Code
Louver/
Lens Frame:
WS = White Louver
RF = Regressed
Floating Extruded
Aluminum Door
Frame
Lamp
Quantity
3 = 3 Lamp
4 = 4 Lamp
Options:
Add appropriate
Suffix to Catalog
No. i.e. (GLR)
Ballast Type:
(Examination)
<20THD <10THD
1-3 Lamp Elec. TT5 X3* I3**
2-2 Lamp Elec. TT5 SB* IB**
2-2 Lamp Elec. TT5 PR**
(40 Watt)*
LOL Dimming TT5 PB*
**Instant Start Standar
d
**Program Start
NOTE:
For TT5 UNV, you must use IB Ballast
Code
Voltage:
120 or 277