ORDERING INFORMATION
Explanation of Catalog Number. Example: MDCG2BX120SW
MDC
MD*C
Recessed or
Surface,
Multi-function
Patient Light
with Perforated
Mesh Shield
G
CEILING
TYPE:
Same Unit
May Be Used
For: Grid (lay-in)
Or: Surface
Mounted
2
LAMP
QUANTITY:
(Ambient/
Reading)
2 Lamps
(Total)
BALLAST TYPE:
(Ambient Reading)
20THD 10THD
1 or 2 Lamp Mag. BX*
1-2 Lamp Elec. SB*
IB*
*Instant Start Standard
VOLTAGE:
120 or 277+
OPTIONS:
Add
appropriate
suffix to
catalog no., ie:
SW.
OPTIONS & ACCESSORIES
ACCESS PLATES: Top wiring access plate is shipped with fixture as
standard. When access plates are required in advance for wiring conve-
nience, specify separately. Catalog Number: ACP.
DRYWALL KIT: Order Catalog Number: FK92X2.
Request Folio OA30-10.
ELECTRONIC SEQUENTIAL SWITCH (Low Voltage): Switch factory
mounted in fixture for ambient and reading light convenience (con-
trolled by pillow switch, by others). SUFFIX: SW.
INDIVIDUAL SWITCHING (Low Voltage): Switches
mounted to
patients bed for use with manufacturers control
system (such as Hill-Rom Side Com System). SUFFIX: DP.
9/7 WATT NIGHT LIGHT: SUFFIX: PL (Lamp not included).
FUSING: Internal fast-blow fusing. SUFFIX: GLR.
Internal slow-blow fusing. SUFFIX: GMF.
RADIO INTERFERENCE FILTER: 120 or 277 volt, 50 or 60 Hz. One per
fixture is standard. SUFFIX: RF.
GERM SHIELD. Order Catalog Number: MD4CLGS22.
ELECTRICAL/WIRING OPTIONS: Consult factory.
SPECIFICATIONS
MATERIALS: Chassis parts are die-formed 20 gauge steel.
Reading light – low iridescence anodized 95% reflective, semi-
specular reflector. Ambient light – flat white acrylic contoured steel
reflector and perforated steel mesh shield with white acrylic overlay.
FINISH: Cavity (reading/ambient lights) — flat white acrylic interi-
or, minimum reflectance 86%. Phosphate undercoating. Chassis
exterior — white baked acrylic enamel.
ELECTRICAL: Thermally protected class “P” ballast C.B.M.
approved, non PCB. If K.O. is within 3" of ballast, use wire suitable
for at least 90°.
LABELS: I.B.E.W. UL and ULc Listed.
*Consult factory for 277 volt.
MD
*
COFFER MDCG2BX
Page 4 of 4 2'x2' RECESSED OR SURFACE, MULTI-FUNCTION PATIENT LIGHTING
INDIRECT AMBIENT LIGHT WITH PERFORATED MESH SHIELD
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902
SECTION 8/Folio R40-22
Job Information Type: