Lightolier LP Series Indoor Furnishings User Manual


 
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • E0109
LP Series LED Steplight LP
Page 2 of 2 Normal AC and/or Emergency Low Level Applications
Lightolier is a Philips group brand
LPS Series “Normally On / Non-Emergency Application” Non-Emergency Power Supply Selection
• 12 VAC applications
• 120 VAC Input Versions rated as Class II Distribution Systems
• UL 3R Enclosures
• Thermal secondary output circuit protection
• Convenient bottom access wiring compartment with terminal lugs
No. of LP Series Input Output Catalog Dimensions
Luminaries Required Voltage Wattage Number A B C
10 120 100 LPS100-12-1 4.88” 6.75” 4.63”
15 120 150 LPS150-12-1 4.88” 6.75” 4.63”
25 120 250 LPS250-12-1 4.88” 6.75” 4.63”
30 120 300 LPS300-12-1 4.88” 6.75” 4.63”
30 277 300 LPS300-12-2 4.88” 6.75” 4.63”
50 120 500 LPS500-12-1 5.63” 8.25” 5.25”
50 277 500 LPS500-12-2 5.63” 8.25” 5.25”
8’ x 4’ Path
Illuminance Values (Fc)
Average = 1.04
Maximum = 3.10
Minimum = 0.30
Avg/Min Ratio = 3.47
Max/Min Ratio = 10.33
See Note #1
3’ x 6’ Area (Shown Above)
Calc. Rep Entrance Area
Illuminance Values (Fc)
Average = 1.38
Maximum = 4.70
Minimum = 0.30
Avg/Min Ratio = 4.60
Max/Min Ratio = 15.67
See Note #1
Multiple Luminaries Single Luminaire
Luminaire #2
Luminaire #1
18” AFF
18” AFF
A
B
C
.3
.5
1.0
.1
.2
3’
8’
.3
.5
1.0
.1
.2
3’
8’
8’ x 3’ Path (Shown Above)
Illuminance Values (Fc)
Average = 1.07
Maximum = 1.80
Minimum = 0.50
Avg/Min Ratio = 2.14
Max/Min Ratio = 3.60
See Note #1
Note #1: Photometry based on clear lens. Please consult factory for frosted/white lens IES files.
C3 Series “Normally Off / Emergency” Application
• 12 VDC Applications
• Maintenance-free, sealed lead calcium battery
• 50 watt can operate maximum 8 LP Luminaire
• 75 watt can operate maximum 13 LP luminaires
5.63”
(14.3 cm)
5.75”
(14.6 cm)
9.5”
(24.1 cm)
C3 2 L
SERIES DC OUTPUT BATTERY TRIM COVER
VOLTAGE WATTAGE FINISH
L = Sealed Lead
Calcium
W = White
B = Black
50 = 50 Watts
75 = 75 Watts
C3 = C3 Series Power
Module
2 = 12 Volt
LM Series “Normally On / Emergency” Application
• NEMA 1 Enclosure
• Maintenance-free, sealed lead calcium battery
• Can operate 14 LP luminaires
LM
Series Input/Output Voltages Mounting Configuration
LM = Mini - Interruptible 1 = 120V/120V w/o Light Switch Option CM = Ceiling Plenum Installation*
Power Supplies 2 = 120V/120V w/ Light Switch Option SM = Surface Wall Mount
3 = 277V/277V w/o Light Switch Option RM = Recessed Wall Mount**
4 = 277V/277V w/ Light Switch Option
5 = 120V/12V w/o Light Switch Option
6 = 120V/12V w/ Light Switch Option
7 = 277V/12V w/o Light Switch Option
8 = 277V/12V w/ Light Switch Option
NOTES:
* (1) MICKIT and (1) MIRDIS accessories included
** Drywall Opening Dimensions: 14.5” W x 24.0” L
3.5”
8.89 cm
14.4”
36.6 cm
24.0”
60.96 cm
150 VA
Total Unit 50 lbs.
w/ Battery (22.7 kg)
See C3 spec sheet for full details
See LM spec sheet for full details