Lightolier LP-6 Indoor Furnishings User Manual


 
Job Information Type:
"JSQPSU3PBE'BMM3JWFS."tt'BY
We reserve the right to change details of design, materials and finish.
XXXMJHIUPMJFSDPN½1IJMJQT(SPVQt
#
Lighting Systems LP-6
1BHFPG -JOFBS1FSG-ZUFÜDN4FNJ1FSGPSBUFE-JHIU51FS'PPU/PNJOBM4FDUJPO
Mounting Accessories
Power Feed End Set
Standard Cable Length is 36” (91.44cm)
Straight Cord: LP1EC36 4 Wire Cord*: LP1EC36X4
Cable/Joiner Assembly
Standard Cable Length is 36” (91.44cm)
Single Cable: LP1C36
Single Cable & Cord: LP1CC36
Single Cable & 4 Wire Cord: LP1CC36X4
Fixture Lengths & Mounting Locations
Ceiling Grid Kit CGK
Includes both Standard 1” (2.54cm)
Tee Bar Clip & Slot Tee Clip
* use for dimming and/or emergency battery packs
4’
8’
48” (121.92cm)
4’ 2” (127.00cm)
96” (243.84cm)
8’ 2” (248.92cm)
12’
16’
20’
24’
144” (366.62cm)
12’ 2” (370.84cm)
96” (243.84cm)
16’ 2” (492.76cm)
96” (243.84cm)
144” (366.62cm)
96” (243.84cm)
20’ 2” (614.68cm)
144” (366.62cm) 144” (366.62cm)
24’ 2” (736.60cm)
Performance
CANDLEPOWER
ZONE 0 22 45 67 90
DEG.
CANDELAS
180 1231 1231 1231 1231 1231
175 1228 1238 1241 1275 1261
165 1184 1255 1310 1399 1401
155 1107 1249 1373 1548 1587
145 966 1187 1397 1663 1726
135 783 1074 1368 1717 1791
125 627 987 1374 1715 1667
115 425 863 1169 1258 1269
105 229 624 751 911 926
95 58 224 231 202 191
90 0 17 25 27 29
85 7 13 20 26 28
75 23 29 38 48 51
65 29 39 51 62 66
55 68 74 92 99 101
45 84 88 99 107 110
35 112 114 121 130 134
25 134 134 139 142 143
15 148 148 151 151 151
5 156 156 159 157 158
0 156 156 156 156 156
REPORT NO: LRL 200-10L
CAT NO: LP1B3T54U
LAMPS: 3 F28T5
LUMENS: 2900
EFFICIENCY: 76.9%
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY
REFLECTANCE
80 70 50
WALL REFLECTANCE
70 50 30 70 50 30 50 30 10
0757575646464464646
1686562585654403837
2625752534945353331
3565044484339312826
4514438443833272422
5473933403429242119
6433429373025221816
7403125342722191614
8362822312419171412
9342520292217161311
10 31 23 18 27 20 15 14 11 9
20% FLOOR CAVITY REFLECTANCE
ROOM CAVITY RATIO
CANDLEPOWER CURVE
DISTRIBUTION
Zone
Lumens % Lamp % Luminaire
0-90 463 5.3 6.9
90-180 6231 71.6 93.1
0-180 6694 76.9 100.0
Calculations are for 28 watt T5 lamps, for 54 watt T5 lamps multiply by 1.7
4-Foot
Module
8-Foot
Module
12-Foot
Module
End Set
Cable/
Joiner
4-Foot Run 11
8-Foot Run 11
12-Foot Run 11
16-Foot Run 211
20'-Foot Run 111 1
24'-Foot Run 21 1