Lightolier LIS6G20LW132 Indoor Furnishings User Manual


 
Lytecel Recessed Fluorescent LIS6G20LW132
Page 2 of 2 6" wide x 48", 20 Cell (1 Row) Parabolic Louver,
Air Return/Static, 1 Lamp T8, IES RP1 For VDT Areas
Lightolier a Genlytecompany www.lightolier.com
Technical Information: (978)657-7600 • Fax(978) 658-0595
631 AirportRoad, Fall River,MA 02720 •(508) 679-8131 •Fax (508) 674-4710
Wereserve the rightto change detailsof design, materialsand finish.
© 2007a Genlyte company
Section 2/Folio G07-32
Job Information Type:
Ordering Information
Explanation ofCatalog Number. Example:LIS6G20LW132120SO
Options/Accessories
Access Plate:Top Wiring accessplate is shippedwith fixture
as standard.When
access platesare required inadvance for wiringconvenience, specify separately.
Order CatalogNumber: ACP5 CSP.
Electrical/Wiring Options: Consult factory.
EM Packor Dimming Ballast: Consult factory.
Fusing: Internal fast-blowfusing. Suffix: GLR.
Internal slow-blowfusing. Suffix: GMF.
Chicago Plenum:Suffix: CP.
Specifications
Performance: Inan installation of1 lamp 32Wsemi-specular luminaires ina
room cavityratio of 1,reflectance 80% ceiling,50% wall, 20%floor, the C.U.
shall notbe less than.58 with aspacing to mountingratio of 1.7perpendicular
to thelamps. To meetIES RP-1 forVDT areas theVCP (visual comfort
probability) shallnot be lessthan 91 eithercrosswise or lengthwiseand the
candela valuebetween 55° and90° in the0° to 90°planes shall notexceed
2521. Candelasat Nadir (0°)not to exceed633.
Air Handling-(LIA)side air passagesfor air return.
Materials: Chassisparts are die-formedcold rolled steel.
Louver: Pre-anodizedaluminum (Coilzak
®
or equal).
Specifications (continued)
Finish: Louver—specularor semi-specular lowiridescence pre-anodized
reflector sheet.Reflector: White bakedpolyester enamel reflector.Chassis
exterior—black bakedpolyester enamel.
Electrical: Thermallyprotected class “P”ballast C.B.M. approved,non PCB. If
K.O. iswithin 3" ofballast, use wiresuitable for atleast 90°.
Labels: I.B.E.W./UL andULc Listed.
This productmay have amercury containing lamp.Manage in accordwith
Disposal Laws.See: www.lamprecycle.org
LI
Lytecel6"
6
Fixture
Width
20
Numberof
Cells:
1 rowof
20 cells
LouverFinish:
L=Low
Iridescence
Semi-
specular
P=Low
Iridescence
S
pecular
W
1
Lamp
Quantity:
(By others)
1=1 Lamp
32
LampFixture
Length:
32=T8
(Nominal 48")
BallastType:
<20THD <10THD
1 LampElec.T8 SO* H
I*
*Instant StartStandard
Other dimmingoptions,consultfactory.
NOTE:
For T8UNV,youmustuseHIBallastCode.
DA=DALIdigitaladdressabledimming.
Options:
Add appropriate
suffix tocatalog
no, ie:(GLR)
Voltage:
120, 277or
UNV=120-277
0.0 45.0 90.0 FLUX
0 633 633 633
5 630 628 635 60
15 590 619 660 175
25 539 599 694 285
35 473 621 760 388
45 373 554 581 389
55 231 260 203 212
65 12 32 21 28
75 2354
85 1121
90 011
Model No. LIS6G20LW132120SO
LER= FP-43.4 IW- 39.00 BF -1.10
Comparativeyearly lightingenergycost per
1000lumens =$5.53
ReportNumber: G1206002
CatalogNumber: LIS6G20LW132120SO
Lamp:F32 T8
Luminaire:6" wideTrofferwith semi-
specularlouver andwhitereflector.
Ballast:Advance REL-2P32-SC
Reportis basedon2850 Lumensperlamp.
Efficiency:54.1%
CIEType-Direct-Indirect
Plane: 0-Deg 90-Deg
SpacingCriteria: 1.2 1.7
ShieldingAngles: 90 90
Plane: 0-Deg 90-Deg
LuminousLength: 47.943 5.816
CANDELADISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
INDEG. 0-DEG. 45-DEG. 90-DEG.
45 2929. 4350. 4564.
55 2242. 2521. 1969.
65 162. 419. 270.
75 39. 55. 104.
85 33. 69. 103.
LUMINANCEDATAINCANDELA/SQ.METER
COEFFICIENTSOFUTILIZATION–
ZONALCAVITYMETHOD.EFFECTIVE
FLOORCAVITYREFLECTANCE0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1 60 58 57 55 54 53 53 52 51
2 56 53 50 50 48 46 48 46 45
3 52 47 44 45 42 40 44 41 39
4 48 43 39 41 37 35 39 37 34
5 44 38 34 37 33 31 36 33 30
6 41 35 30 33 30 27 33 29 27
7 38 32 27 30 27 24 30 26 24
8 36 29 25 28 24 22 27 24 21
9 33 27 22 26 22 19 25 22 19
10 31 24 20 24 20 18 23 20 18
ZONE LUMENS %LAMP %FIXT
00-030 0520 18.3 33.7
00-040 909 31.9 58.9
00-060 1510 53.0 97.9
00-090 1542 54.1 100.0
90-180 0000 0.0 000.0
00-180 1542 54.1 100.0
ZONALLUMENSUMMARY
0.0 45.0 90.0 FLUX
0 662 662 662
5 641 643 664 61
15 630 644 652 181
25 556 620 712 292
35 487 678 821 416
45 398 623 647 430
55 269 293 208 236
65 1 29 17 21
75 0253
85 0121
90 111
Model No. LIS6G20PW132120SO
LER= FP-45.8 IW- 39.0 BF -1.10
Comparativeyearly lightingenergycost per
1000lumens =$5.24
ReportNumber: G1206003
CatalogNumber: LIS6G20PW132120SO
Lamps:F32 T8
Luminaire:6" wideTrofferwith specular
louverand whitereflector.
Ballast:Advance REL-2P32-SC
Reportis based on2850Lumensper lamp.
Efficiency:57.6%
CIEType-Direct-Indirect
Plane: 0-Deg 90-Deg
SpacingCriteria: 1.2 1.7
ShieldingAngles: 90 90
Plane: 0-Deg 90-Deg
LuminousLength: 47.943 5.816
CANDELADISTRIBUTION
COEFFICIENTSOFUTILIZATION–
ZONALCAVITYMETHOD.EFFECTIVE
FLOORCAVITYREFLECTANCE0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1 64 62 60 59 57 56 56 55 54
2 60 56 53 53 51 49 51 49 47
3 55 50 46 48 45 42 46 44 42
4 51 45 41 43 40 37 42 39 36
5 47 41 36 39 35 32 38 35 32
6 44 37 32 35 31 29 34 31 28
7 41 33 29 33 28 25 31 28 25
8 38 31 26 29 26 23 29 25 23
9 35 28 24 27 23 20 26 23 20
10 33 26 21 25 21 19 24 21 18
ZONE LUMENS %LAMP %FIXT
00-030 535 18.8 32.6
00-040 950 33.3 57.9
00-060 1617 56.7 98.5
00-090 1641 57.6 100.0
90-180 0000 0.0 000.0
00-180 1641 57.6 100.0
ZONALLUMENSUMMARY
Reflector:
W
=White Reflector
StandardLytecel
LI
MountingHeight
Lengthwise Crosswise
Room Luminaires Luminaires
Size 0DegPlane 90DegPlane
8.5 10 8.5 10 8.5 10 8.5 10
30x30 91 88 87 82 92 88 86 80
40x40 92 88 87 85 94 88 88 84
60x30 92 88 87 84 93 88 86 81
60x60 92 88 87 85 94 90 88 85
100x100 91 89 88 85 95 92 88 86
TYPICALV.C.P.'s
MountingHeight
Lengthwise Crosswise
Room Luminaires Luminaires
Size 0DegPlane 90DegPlane
8.5 10 8.5 10 8.5 10 8.5 10
30x30 90 82 82 81 93 88 85 78
40x40 91 82 82 83 94 88 87 82
60x30 91 82 82 83 93 88 86 80
60x60 91 82 83 83 94 90 87 84
100x100 91 82 83 93 95 91 89 85
TYPICALV.C.P.'s
AVERAGE AVERAGE AVERAGE AVERAGE
INDEG. 0-DEG. 45-DEG. 90-DEG.
45 3130. 4896. 5087.
55 2605. 2838. 2018.
65 8. 379. 217.
75 10. 53. 98.
85 23. 67. 113.
LUMINANCEDATAINCANDELA/SQ.METER
BodyStyle:
A=Air Return
S=Static
ForNYCCode–Local3Manufactured
LN
CeilingType:
G=9/16"or
15/16"Grid
T =SlotGrid
A=9/16"Tegular
Grid
D=15/16"Tegular
Grid