Lightolier IS_CACS Indoor Furnishings User Manual


 
FIBERGLASS
PAD (DISCARDED)
INSTALLATION OF CEILING MOUNT CYLINDER TO
STEM (Fig. 1 & 3)
1. Attach (2) SPRING CLIPS to CYLINDER HOUSING by sliding
SPRING CLIPS onto (2) raised pockets on top of CYLINDER
HOUSING. NOTE: Discard SPRING CLIPS for Cylinders which
do not have the raised pockets; these cylinders have integral tap
holes. (Fig. 3)
2. For C7CS series cylinders, tear off the fiberglass pad from top
of cylinder. The remaining fiberglass pad can be left inside of
SUPPORT COVER or removed. (Fig. 4)
3. Make Connections. Bare Copper and/or green insulation wire(s)
must be connected to SUPPLY GROUND. Connect WHITE
BALLAST LEAD to NUETRAL (WHITE) SUPPLY LEAD. Connect
BLACK BALLAST LEAD to HOT SUPPLY LEAD. Use wire nuts
(provided). Place spliced leads into SUPPORT COVER.
4. Align (2) holes in SUPPORT COVER with (2) SPRING CLIPS or
Tap holes, then tighten with (2) SCREWS (provided). (Fig. 1 & 3)
INSTRUCTIONS FOR SHORTENING STEM
A
TTENTION: Cut end with smaller diameter holes onl
y
. (Fig.1)
CAUTION: Eye protection should always be worn when using hand
and power tools during the cutting procedure outlined below.
1. Using pipe cutting tool, shorten STEM to appropriate length. Clean
all burrs and sharp edges from cut end of Stem.
2. Position DRILL LOCATOR over cut end of STEM (Fig. 5). Gently
tap down on DRILL LOCATOR until fully seated on end of STEM.
3. Position CENTER PUNCH into bottom SLOT in DRILL LOCATOR
and mark a small dimple in STEM (Fig. 6).
4. Align 1/8" DRILL BIT (local hardware item) into bottom slot of
DRILL LOCATOR so tip of DRILL BIT rests in dimple (Fig. 7).
5. Drill hole completely through STEM allowing DRILL LOCATOR
to guide DRILL BIT. Do not force DRILL BIT. It is recommended to
hold DRILL LOCATOR securely in a
vise or other device prior to drilling hole.
FIG. 3
SPRING
CLIPS
A COMPANY
631 Airport Road, Fall River, MA 02720
DRILL BIT
SLOT SLOT
CENTER
PUNCH
FIG. 7
FIG.6
STEM (CUT)
DRILL LOCATOR
HAMMER
FIG. 4
SUPPORT
COVER
FIBERGLASS
PAD (DISCARDED)
FIG. 5
READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE
This fixture is intended for installation in accordance with the National Electrical Code and local regulations. To
assure full compliance with local codes and regulations, check with your local electrical inspector before
installation. To prevent electric shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
INSTRUCTION SHEET NO.
IS:CACS
Page 2 of 2
A0604
INSTALLATION PROCEDURE FOR: CEILING MOUNT STEM KIT CACS AND C4CS SERIES
USED WITH CEILING MOUNT CYLINDERS (ORDER SEPARATELY)
WARNING: USE ONLY FIXTURE PROVIDED BY LIGHTOLIER. USE OF OTHER MANUFACTURES’ FIXTURES MAY VOID