INSTRUCTIONSHEETNO.
INSTALLATION PROCEDURE FOR
LOW VOLTAGE
REFLECTOR TRIM IN THE 1000LV FRAME-IN KIT
lS:1055LV
0s90
Page 1
of 2
READ AND UNDERSTAND THESE lNSTRU~lONS BEFORE INSTALLING FIXTURE.
This fixture is intended for installation in accordance with the National Electrical Code and local regulation.
To assure full compliance with local codes and regulations, check with your local electrical inspector before
installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.
Retain these instructions for maintenance reference.
~~%~
FIG. A
FIG. B
FIG. C
FIG. D
1. FRAME-IN
2. CLOSE-IN
3. SNAP~N
4. PUSH-UP
WARNING: BEFORE INSTALLING REFLECTOR TRIM TO FRAME-IN KIT, REAO MARKINGS IN REFLECTOR TRIM
AND ‘IN BOCK~ CUP OF FRAME-IN-KIT TO DErERMINE LAMP WAlTAGE AND TYPE APPLICABLE FOR YOUR
lNBTA1.L&TiON. IF I.C. TYPE FRAMING KIT IS USED, IT MAY BE INSTALLED IN DIRECT CONTACT WITN INSULATED
CSIUNGS. IF A NON I.C. TYPE FRAME4N.KfT IS USED, DO NOT INSTALL INSULATION WITHIN 31NCHSB OF FI)MJRE
SIDE OR WIRING COMPARTMENT, NOR ABOVE FIXTURE IN SUCH A MANNER TO ENTRAP HSAT.
1. FRAME-IN (Fig. A)
See Frame-In Kit Instruction Sheet for installation
4
r-
procedure.
FRAMINGKIT
,!;;
2. ROTATE ROTO-CLIPS (Fig. B)
MOUNTSFLUSH
ONCEILINGMATERIAL
,..’
As shown in Fig. E.
0“ \
.-.,,:.,--
;’,.’.’.; :.:.-..,
3. SNAP.ON (Fig. C).
, ....:.:
- ... .’$.’.
Insert SOCKET through RECTANGLE HOLE on top
\ ..,-.... .-
CEILING
-,:.-...-:.
of REFLECTOR TRIM. Engage TAB from SOCKET
MATERIAL
CUP into one of the SLOTS on top of REFLECTOR
ROTO.CLIP ‘““::;~y ;
POSITION
TRIM and push other end of SOCKET CUP with
:., ,,
LANCING into the other SLOT (Fig. F),
FIG. E
4. PUSH-UP (Fig. D). SOCKETCUP
Push REFLECTOR TRIM into ceiling until flange
is flueh to ceiling (Fig. D).
RECTANGLEHOLE ~
N~E Socket manufacturers have suggested that
SLOTa
socket may fail after 3 to 6 ralampings. If this
occurs, socket can be replaced by disconnecting
REFLECTORTRIM
male connectors (attached to socket leads) from
female connectors (attached to fixture leads) and
replacing it with a new socket procured through
Lightolier (Fig. G).
INSULATINGSLEEVING
MALECONNECTORa
SEE BACK PAGE FOR LAMP INSTALLATION
(ATTACHEDTO SOCKETWIRE)
AND ADJU~MENT.
FEMALECONNECTORS
(ATTACHEDTO FIXTUREWIRES)
MR16SOCKET
FIG. G
1- I <51“17<> l-l 1= ,a@ :v:::::i,N:r::::,E:i:T:j