Lightolier HP90 (H9) Indoor Furnishings User Manual


 
4
Housing
Earthquake
Clip
5
Install fixture into Ceiling System (by others).
For Coffaire (CF) and Mini-Beam (MB), open
Lamp Shield by gripping Narrow Flange of
Lamp Shield and pull Lamp Shield towards you,
letting the opposite side of the Lamp Shield rest
on the Hinge Pins (Wide Flange).
For Mini-Beam Ballast Access Cover
Compartment.
Ballast is accessed by removing the ceiling tile
adjacent to the Mini-Beam. Remove Screw at
end of Ballast Access Cover and slide Ballast
Access Cover towards Housing End. Lift Ballast
Access Cover for easy access to Ballast. To
replace Ballast Access Cover reverse the
procedure.
To install fixture into the ceiling system (by
others), bend Earthquake Clips out 90 degress
from Housing End. Install fixture into ceiling
system. Secure the fixture to the ceiling system
by bending the Locking Tabs on the Earthquake
Clips towards the T-bar.
Locking Tab
Earthquake
Clip
Housing
T-bar
(by others)
Locking
Tab
Locking
Tab
Earthquake
Clip
T-bar
(by
others)
Ceiling System
(by others)
Coffaire
Mini-Beam
COFFAIRE (CF) MINI-BEAM (MB)
Hinge Pin
(Wide Flange)
Hinge Pin
(Narrow Flange)
Lamp Shield
6
Ballast Access
Cover
Screw
Housing
End
Hinge Pin
Lens
HP90 Lens Removal
Push Lens to one side A , and pull Lens off
Hinge Pins B and downward. Unlink Lens from
all Hinge Pins (both ends of fixture) clearing the
lamps for removal.
O
O
A
B
O
O