Lightolier HP90 (H9) Indoor Furnishings User Manual


 
Lightolier
45 INDUSTRIAL WAY, WILMINGTON, MA 01887
PARAPLUS (PP), COFFAIRE (CF), MINI-BEAM (MB), HP90 (H9)
INSTALLATION INSTRUCTIONS
1
59-31115-003 Printed in U.S.A.
IMPORTANT: For Paraplus remove the Louver
before installing fixture into ceiling system (by
others). To remove the Louver, depress one
side of the Louver to clear the Hinge Pin and
Access Plate for CF/PP
Remove Access Plate (snaps in and out of
position). Bend Housing Tab up to attach
ground screw to green screw on the Housing
Tab. Then bend Housing Tab down into the
Housing as shown. Install Access Plate.
2
Housing
Hinge
Pin
Louver
Housing
Hinge Pin
Louver
Housing
Housing Tab
pull the Louver towards you. Rotate the Louver
upwards and remove from the Hinge Pins on
the opposite side of the Housing.
Louver
Hinge
Pin
Overlay
Access Plate
Access Plate for Mini-Beam (MB).
Remove Access Plate by sliding Access Plate
in the direction of Arrow 1. To remove, lift up
and slide in the direction of Arrow 2. Bend
Housing Tab up out of Housing and make
ground and ballast connections. Bend Housing
Tab back to original position. Replace the
Access Plate by reversing removal procedure.
3
Access
Plate
Opening
Access
Plate
Opening
Access
Plate
Ground
Screw
Fixture
Tab
Access
Plate
Opening
2.
Tab
1.
© a Genlyte company