Lightolier HDS2GLW1FT Indoor Furnishings User Manual


 
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 a Philips Group Section 5/Folio M33-30
Job Information Type:
Lightolier is a Philips group brand
HP90 Semi HDS2GLW1FT
Page 2 of 2 Direct/Indirect Semi-Recessed Fluorescent
2' x 2' with Acrylic Linear Prismatic Lens, 1 Lamp TT5
Ordering Information
Explanation of Catalog Number. Example: HDS2GLW1FTUNVPR
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: A.
Internal slow blow fusing: SUFFIX: C.
Drywall Kit: Order Catalog Number: FK92X2.
Electrical Wiring Options: Emergency Packs are only avalable for remote mounting.
Consult factory.
For motion or light sensor: See Folio OA20-10.
Specifications
Performance: In an installation of 1 lamp 40W luminaires in a room cavity
ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not
be less than .78. To reduce glare the average brightness at 65° shall not exceed
2439 candelas per square meter. To control veiling reflections, luminaire output
in the 30°-90° zone shall not be less than 76.5%.
Materials: Chassis parts are die-formed code gauge steel.
Lamp Shield: Linear prismatic translucent DR acrylic lens.
Finish: Chassis exterior – Soft white post painted polyester powder. Cavity
Soft white post painted polyester powder. Rust preventative undercoating.
Reflector – Soft white post painted polyester powder.
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of
ballast, use wire suitable for at least 90°.
UL Listed for damp locations.
Labels: I.B.E.W./UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with Disposal Laws. See:
www.lamprecycle.org
HD
Options:
Add appropriate
suffix to catalog
no., ie: (A)
HP90
Direct/Indirect
Semi-Recessed
S
Body Style:
S = Static
2
Fixture
Width
G
Ceiling Type:
Fits both
Standard Grid
and
Slot Grid
L
Acrylic Lens
FT
Lamp:
(By Others)
W
Reflector:
White
1
Lamp
Quantity
1=1 Lamp
Ballast Type:
<20THD <10THD
1 Lamp Elec. TT5 SB* IB**
(40 Watt)
1 Lamp Elec. TT5 PR†
(40 Watt)
1 Lamp Elec. TT5 BE*
(50 Watt)
1 Lamp Elec. TT5 –BF*
(55 Watt)
LOL Dimming TT5 PB
*Instant Start Standard.
Other dimming options. Consult factory.
NOTE:
For TT5 40W UNV, you must use IB or PR Ballast Code.
†Program Rapid Start
0.0 45.0 90.0 FLUX
0 737 737 737
5 731 734 736 70
15 699 712 722 201
25 640 669 694 308
35 556 604 646 377
45 449 519 582 399
55 321 425 511 376
65 183 333 428 317
75 81 246 341 242
85 17 174 277 172
90 3 115 208
Model No. HDS2GLW1FTUNVPR
LER = FP - 64.1 IW - 38.4 BF - 1.0
Comparative yearly lighting energy cost per
1000 lumens = $3.74
Report Number: G2008239
Catalog Number: HDS2GLW1FTUNVPR
Lamps: (1) F40 TT5
Luminaire: HP90 Semi-Recssed 2' x 2' with
linear prismatic lens.
Ballast: ICN-2TTP40-SC
Report is based on 3150 Lumens per lamp.
Efficiency: 78.2%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.4
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 23.040 23.040
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 1687. 1949. 2186.
55 1431. 1895. 2278.
65 1043. 1897. 2439.
75 667. 2026. 2808.
85 267. 2735. 4353.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01837874737067706765
02756761635854605653
03685952554945534844
04625244494238474137
05574639433732423632
06524134393328383228
07493730362925342925
08453427322622312622
09423125302420292420
10 40 29 22 28 22 18 27 22 18
ZONE LUMENS % LAMP % FIXT
00-030 579 18.4 23.5
00-040 957 30.4 38.8
00-060 1723 55.0 70.3
00-090 2463 78.2 100.0
90-180 0000 0.0 000.0
00-180 2463 78.2 100.0
ZONAL LUMEN SUMMARY
Voltage:
120, 277 or
UNV=120-277