Lightolier HDB2SLW224 Indoor Furnishings User Manual


 
For Factory Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 a Philips Group Section 5/Folio M33-15
Job Information Type:
Lightolier is a Philips group brand
HP90 Surface HDB2SLW214 or 224
Page 2 of 2 Direct/Indirect Surface Mounted Fluorescent
2' x 2' with Acrylic Linear Prismatic Lens, 2 Lamp T5
Ordering Information
Explanation of Catalog Number. Example: HBS2GLW224UNVPG
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: A.
Internal slow blow fusing: SUFFIX: C.
Electrical Wiring Options: Emergency Packs are only avalable for remote mounting.
Consult factory.
For motion or light sensor. See Folio OA20-10..
Specifications
Performance: In an installation of 2 lamp 24W luminaires in a room cavity
ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not
be less than .77. To reduce glare the average brightness at 65° shall not exceed
3196 candelas per square meter. To control veiling reflections, luminaire output
in the 30°-90° zone shall not be less than 77.3%.
Materials: Chassis parts are die-formed code gauge steel.
Lamp Shield: Linear prismatic translucent DR acrylic lens.
Finish: Chassis exterior – Soft white post painted polyester powder. Cavity
Soft white post painted polyester powder. Rust preventative undercoating.
Specifications (continued)
Reflector – Soft white post painted polyester powder.
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°.
UL Listed for damp locations.
Labels: I.B.E.W./UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with
Disposal Laws. See: www.lamprecycle.org
HD
Options:
Add appropriate
suffix to catalog
no., ie: (A)
HP90
Direct/Indirect
Surface
B
Body Style:
B = Surface
Mounted
2
Fixture
Width
S
Ceiling Type:
Surface
L
Acrylic Lens Lamp:
(By Others)
14=T5 14W
24=T5HO 24W
(Nominal 24")
W
Reflector:
White
2
Lamp
Quantity
2=2 Lamp
Ballast Type:
<20THD <10THD
2 Lamp Elec. T5 PG ††
(14 Watt)
2 Lamp Elec. T5HO PG ††
(24 Watt)
††Program Rapid Start (UNV only)
Model No. HDB2SLW224120PG
LER = FP - IW - 46.7 BF - 1.0
Comparative yearly lighting energy cost per
1000 lumens = $3.63
Report Number: G2008227A
Catalog Number: HDB2SLW224120PG
Lamps: (2) F24T5 HO
Luminaire: HP90 Surface 2' x 2' with linear
prismatic lens.
Ballast: ER224120M
Report is based on 2000 Lumens per lamp.
Efficiency: 77.1%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.4
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 23.040 23.040
Height of Side: 2.280 2.280
0.0 45.0 90.0 FLUX
0 885 885 885
5 882 882 885 84
15 844 858 870 243
25 774 808 839 373
35 674 735 795 460
45 546 643 731 495
55 391 537 655 474
65 227 430 561 409
75 102 323 461 320
85 22 225 368 226
90 3 146 265
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 2051. 2415. 2746.
55 1743. 2394. 2920.
65 1293. 2450. 3196.
75 840. 2660. 3797.
85 346. 3536. 5783.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01827773726966696664
02736660625753595551
03675750544843514743
04615043474136464036
05564537423631413531
06514033383227373127
07473629352824332824
08443326322621312521
09413024292319282319
10 39 28 22 27 21 17 26 21 17
ZONE LUMENS % LAMP % FIXT
00-030 699 17.5 22.7
00-040 1160 29.0 37.6
00-060 2129 53.2 69.0
00-090 3083 77.1 100.0
90-180 0000 00.0 000.0
00-180 3083 77.1 100.0
ZONAL LUMEN SUMMARY
Voltage:
120, 277 or
UNV=120-277
0.0 45.0 90.0 FLUX
0 511 511 511
5 508 509 512 49
15 486 495 502 140
25 446 466 484 215
35 389 425 458 266
45 315 370 420 285
55 227 310 376 274
65 131 248 324 237
75 59 188 264 185
85 13 131 212 130
90 2 84 151
Model No. HDB2SLW214120PG
LER = FP - 58.1 IW - 30.6 BF - 1.O
Comparative yearly lighting energy cost per
1000 lumens = $4.13
Report Number: G2008276A
Catalog Number: HDB2SLW214120PG
Lamps: (2)F14T5
Luminaire: HP90 Semi-Recessed 2' x 2'
with linear prismatic lens.
Ballast: ER21120MHT
Report is based on 1200 Lumens per lamp.
Efficiency: 74.1%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.4
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 23.040 23.040
CANDELA DISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 1183. 1390. 1578.
55 1012. 1382. 1676.
65 746. 1413. 1846.
75 486. 1548. 2174.
85 204. 2059. 3332.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01797470696663666461
02716458595551575350
03645548524642504541
04584941464035443935
05544336413530393430
06493932373126353026
07473528332723322723
08433225302520292420
09402923282218272218
10 37 27 21 26 20 17 25 20 17
ZONE LUMENS % LAMP % FIXT
00-030 403 16.8 22.7
00-040 669 27.9 37.6
00-060 1228 51.2 69.0
00-090 1780 74.1 100.0
90-180 00000.0000.0
00-180 1780 74.1 100.0
ZONAL LUMEN SUMMARY