Lightolier H9S2GLR217 Indoor Furnishings User Manual


 
HP90 Recessed Fluorescent H9S2GLR117 or 217
Page 2 of 2 Direct/Indirect 2' x 2' with Acrylic Linear Prismatic Lens
Static, 2 Lamp T8
Job Information Type:
Ordering Information
Explanation ofCatalog Number. Example: H9S2GLR217UNVHI
Options/Accessories
Fusing: Internal fastblow fusing: SUFFIX: GLR.
Internal slowblow fusing: SUFFIX: GMF.
Drywall Kit:Order Catalog Number:FK92X2 .
Electrical WiringOptions: Consult factory.
For motionor light sensor. SeeFolio OA20-10.
Specifications
Performance: Inan installation of2 lamp 17Wluminaires in aroom cavity
ratio of1, with reflectance80% ceiling, 50%wall, 20% floor, theC.U. shallnot
be lessthan .89. To reduceglare theaverage brightness at65° shall notexceed
2591 candelasper square meter. Tocontrol veiling reflections,luminaire output
in the30°-90° zone shallnot be lessthan 75.8%.
Materials: Chassisparts are die-formedcode gauge steel.
Lamp Shield:Linear prismatic translucentDR acryliclens.
Finish: Chassisexterior – bakedwhite polyester enamel.Cavity – baked
white polyesterenamel. Rust preventativeundercoating. Reflector –low irides-
cence specularaluminum .95% reflectance.
Specifications (continued)
Electrical: Thermallyprotected class “P’ballast C.B.M. approved,non PCB. If
K.O. iswithin 3" ofballast, use wiresuitable for atleast 90°.
UL Listedfor damp locations.
Labels: I.B.E.W./UL andULc Listed.
This productmay have amercury containing lamp.Manage in accordwith
Disposal Laws.See: www.lamprecycle.org
Options:
Addappropriate
suffixtocatalog
no.,ie:(GLR)
HP90
Direct/Indiect
Recessed
S
BodyStyle:
S=Static
2
Fixture
Width
G
CeilingType:
Fitsboth
StandardGrid
and
SlotGrid
L
AcylicLens
17
Lamp:
(ByOthers)
17=T817W
(Nominal24")
R
Reflector:
Specular
Aluminum
Lamp
Quantity
1=1Lamp
2=2Lamp
BallastType:
<20THD <10THD
1or2LampElec.T8 SO* H
I *
LOLDimmingT8 PS
*InstantStartStandard
Otherdimmingoptions.Consultfactory.
NOTE: ForT8UNV,youmustuseH
I
BallastCode.
Lightolier a Genlytecompany www.lightolier.com
Technical Information: (978)657-7600 •Fax (978) 658-0595
631 AirportRoad, Fall River, MA02720 • (508)679-8131 • Fax(508) 674-4710
Wereserve the right tochange details ofdesign, materials andfinish.
© 2007a Genlyte company
Section 5/Folio M32-17
Voltage:
120,277or
UNV=120-277
H9
StandardHP90
HY
ForNYCCode–IB.E.W.Manufactured
HN
ForNYCCode–Local3Manufactued
Model No. H9S2GLR117120SO
LER= FP-48.7 IW- 17.96 BF -0.88
Comparativeyearly lightingene gycost per
1000lumens =$4.92
ReportNumber: G2007124
CatalogNumber: H9S2GLR117120SO
Lamps:(1) F17T8
Luminaire:HP90 2'x2' withlinear
prismaticlens.
Ballast:REL1P-32-SC (Advance)
Reportis basedon1375 Lumensperlamp.
Efficiency:72.5%
CIEType-Direct-Indirect
Plane: 0-Deg 90-Deg
SpacingCriteria: 1.2 1.4
ShieldingAngles: 90 90
Plane: 0-Deg 90-Deg
LuminousLength: 22.800 22.800
0.0 45.0 90.0 FLUX
0 316 316 316
5 314 315 317 30
15 298 307 314 87
25 271 290 307 134
35 233 265 292 165
45 186 231 269 177
55 133 190 237 168
65 80 143 199 140
75 37 89 114 85
85 88712
90 221
CANDELADISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
INDEG. 0-DEG. 45-DEG. 90-DEG.
45 708. 879. 1023.
55 624. 891. 1112.
65 509. 910. 1267.
75 385. 925. 1185.
85 247. 247. 216.
LUMINANCEDATAINCANDELA/SQ.METER
COEFFICIENTSOFUTILIZATION–
ZONALCAVITYMETHOD.EFFECTIVE
FLOORCAVITYREFLECTANCE0.20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1 79 75 72 70 68 66 68 66 64
2 71 65 60 61 57 54 59 55 52
3 65 57 51 53 48 44 51 47 44
4 59 50 43 47 42 38 45 41 37
5 54 44 38 42 36 32 41 36 32
6 50 40 33 38 32 28 37 32 28
7 46 36 30 34 29 25 33 28 24
8 43 33 27 31 26 22 30 25 22
9 40 30 24 29 23 20 28 23 20
10 38 28 22 27 21 18 26 21 18
ZONE LUMENS %LAMP %FIXT
0- 30 250 182 251
0- 40 416 302 417
0- 60 760 553 763
0- 90 997 725 1000
90-180 0 00 00
0-180 997 725 1000
ZONALLUMENSUMMARY
Model No. H9S2GLR217120SO
LER= FP-56.6 IW- 31.9 BF -0.88
Comparativeyearly lightingene gycostper
1000lumens =$4.24
ReportNumber: G2007120
CatalogNumber: H9S2GLR217120SO
Lamps:(2) F17T8
Luminaire:HP90 2'x2' withlinear
prismaticlens.
Ballast:B232I120RH-A (Universal)
Reportis basedon 1375Lumensper lamp.
Efficiency:74.6%
CIEType-Direct-Indirect
Plane: 0-Deg 90-Deg
SpacingCriteria: 1.2 1.5
ShieldingAngles: 90 90
Plane: 0-Deg 90-Deg
LuminousLength: 22.800 22.800
0.0 45.0 90.0 FLUX
0 615 615 615
5 612 615 617 59
15 586 605 618 171
25 539 580 616 267
35 470 538 603 337
45 382 482 563 368
55 276 405 491 353
65 164 309 407 294
75 73 193 230 177
85 16 17 14 26
90 322
CANDELADISTRIBUTION
AVERAGE AVERAGE AVERAGE AVERAGE
INDEG. 0-DEG. 45-DEG. 90-DEG.
45 1453. 1834. 2142.
55 1294. 1899. 2303.
65 1044. 1967. 2591.
75 759. 2006. 2390.
85 494. 525. 432.
LUMINANCEDATAINCANDELA/SQ.METER
COEFFICIENTSOFUTILIZATION–
ZONALCAVITYMETHOD.EFFECTIVE
FLOORCAVITYREFLECTANCE0.20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1 81 77 74 72 70 67 69 67 65
2 73 67 61 63 58 55 60 57 54
3 66 58 52 55 49 45 52 48 45
4 60 51 44 48 43 38 46 42 38
5 55 45 38 43 37 33 41 36 32
6 51 41 34 39 33 28 37 32 28
7 47 37 30 35 29 25 34 29 25
8 44 33 27 32 26 22 31 26 22
9 41 31 24 29 24 20 28 23 20
10 38 28 22 27 22 18 26 21 18
ZONE LUMENS %LAMP %FIXT
0- 30 496 181 242
0- 40 833 303 406
0- 60 1555 565 758
0- 90 2052 746 1000
90-180 0 00 00
0-180 2052 746 1000