Lightolier H9S2GLR154 Indoor Furnishings User Manual


 
HP90 Recessed Fluorescent H9S2GLR254 or 154
Page 2 of 2 Direct/Indirect – 2' x 4' with Acrylic Linear Prismatic Lens
Static, 1 or 2 Lamp T5
Job Information Type:
Ordering Information
Explanation of Catalog Number. Example: H9S2GLR254UNVPGGLR
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: GLR.
Internal slow blow fusing: SUFFIX: GMF.
Drywall Kit: Order Catalog Number: FK92X4.
Electrical Wiring Options: Consult factory.
For motion or light sensor: See Folio OA20-10.
Specifications
Performance: In an installation of 2 lamp 54W luminaires in a room cavity
ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not
be less than .88. To reduce glare the average brightness at 65° shall not exceed
3776 candelas per square meter. To control veiling reflections, luminaire output
in the 30°-90° zone shall not be less than 74.1%.
Materials: Chassis parts are die-formed code gauge steel.
Lamp Shield: Linear prismatic translucent DR acrylic lens.
Finish: Chassis exterior – baked white acrylic enamel. Cavity – baked flat
white acrylic enamel. Phosphate undercoating. Reflector – low iridescence
specular aluminum 95% reflectance.
Specifications (continued)
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°.
UL Listed for damp locations.
Labels: I.B.E.W./UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with
Disposal Laws. See: www.lamprecycle.org
Options:
Add appropriate
suffix to catalog
no., ie: (GLR)
HP90
Direct/Indirect
Recessed
S
Body Style:
S = Static
2
Fixture
Width
G
Ceiling Type:
Fits both
Standard Grid
and
Slot Grid
L
Acrylic Lens
54
Lamp:
(By Others)
54=T5 54W
(Nominal 48")
R
Reflector:
Specular
Aluminum
Lamp
Quantity
1=1 Lamp
2=2 Lamp
Ballast Type:
<20THD <10THD
1 Lamp Elec. T5 HO PG ††
(54 Watt)
2 Lamp Elec. T5 HO PG ††
(54 Watt)
††Program Rapid Start (UNV only)
0.0 45.0 90.0 FLUX
0 1393 1393 1393
5 1374 1395 1411 133
15 1323 1360 1366 382
25 1235 1232 1213 566
35 1101 1028 1017 651
45 889 796 818 631
55 598 566 642 529
65 319 390 545 410
75 121 241 317 239
85 10 10 10 24
90 222
Model No. H9S2GLR154UNVPG
LER = FP - 57.1 IW - 62.4 BF - 1.0
Comparative yearly lighting energy cost per
1000 lumens = $4.20
Report Number: G2006154
Catalog Number: H9S2GLR154UNVPG
Lamps: F54 T5 HO
Luminaire: HP90 2' x 4' with linear
prismatic lens.
Ballast: Advance ICN-2S54 UNV PG
Report is based on 4400 Lumens per lamp.
Efficiency: 81.0%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.3 1.2
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 47.760 23.760
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 1717. 1537. 1580.
55 1424. 1347. 1528.
65 1031. 1260. 1761.
75 638. 1271. 1672.
85 157. 157. 157.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01898582807775777573
02817469706662676461
03746659625753605552
04685851555045534945
05635245504439484339
06584740453935443834
07544336413531403531
08503933383228373127
09473630352925342925
10 44 33 27 32 27 23 31 26 23
ZONE LUMENS % LAMP % FIXT
00-030 1081 24.6 30.3
00-040 1732 39.4 48.6
00-060 2892 65.7 81.1
00-090 3566 81.0 100.0
90-180 0000 0.0 000.0
00-180 3566 81.0 100.0
ZONAL LUMEN SUMMARY
Model No. H9S2GLR254UNVPG
LER = FP - 66.5 IW - 112.39 BF - 1.0
Comparative yearly lighting energy cost per
1000 lumens = $3.61
Report Number: G2006118
Catalog Number: H9S2GLR254UNVPG
Lamps: F54 T5 HO
Luminaire: HP90 2' x 4' with linear
prismatic lens.
Ballast: B254UNV-E
Report is based on 4400 Lumens per lamp.
Efficiency: 84.6%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.3 1.4
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 46.800 22.800
0.0 45.0 90.0 FLUX
0 2340 2340 2340
5 2320 2339 2354 223
15 2228 2326 2406 658
25 2079 2280 2417 1044
35 1851 2134 2220 1303
45 1548 1790 1827 1348
55 1173 1345 1428 1197
65 771 963 1099 950
75 383 625 665 597
85 75 95 60 125
90 000
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 3179. 3676. 3752.
55 2970. 3405. 3615.
65 2649. 3309. 3776.
75 2149. 3507. 3731.
85 1250. 1583. 1000.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01928884827977797774
02837670716763696561
03766759635752605651
04695951564944544844
05645245504338484238
06594739453833433733
07544335413429393429
08503932373126363026
09473629342824332723
10 44 33 26 31 25 21 31 25 21
ZONE LUMENS % LAMP % FIXT
00-030 1926 21.9 25.9
00-040 3229 36.7 43.4
00-060 5774 65.6 77.5
00-090 7446 84.6 100.0
90-180 0000 00.0 000.0
00-180 7446 84.6 100.0
ZONAL LUMEN SUMMARY
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2006 a Genlyte company Section 5/Folio M32-11
Voltage:
120, 277 or
UNV=120-277
H9
Standard HP90
HY
For NYC Code – I.B.E.W. Manufactured
HN
For NYC Code – Local 3 Manufactured