Lightolier H9S1GLR128 Indoor Furnishings User Manual


 
HP90 Recessed Fluorescent H9S1GLR228 or 128
Page 2 of 2 Direct/Indirect – 1' x 4' with Acrylic Linear Prismatic Lens
Static, 1 or 2 Lamp T5
Job Information Type:
Ordering Information
Explanation of Catalog Number. Example: H9S1GLR228UNVPG
Options/Accessories
Fusing: Internal fast blow fusing: SUFFIX: GLR.
Internal slow blow fusing: SUFFIX: GMF.
Drywall Kit: Order Catalog Number: FK91X4.
Electrical Wiring Options: Consult factory.
For motion or light sensor: See Folio OA20-10.
Specifications
Performance: In an installation of 2 lamp 28W luminaires in a room cavity
ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not
be less than .93. To reduce glare the average brightness at 65° shall not exceed
3851 candelas per square meter. To control veiling reflections, luminaire output
in the 30°-90° zone shall not be less than 72.1%.
Materials: Chassis parts are die-formed code gauge steel.
Lamp Shield: Linear prismatic translucent DR acrylic lens.
Finish: Chassis exterior – baked white acrylic enamel. Cavity – baked flat
white acrylic enamel. Phosphate undercoating. Reflector – low iridescence
specular aluminum 95% reflectance.
Specifications (continued)
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°.
UL Listed for damp locations.
Labels: I.B.E.W./UL and ULc Listed.
This product may have a mercury containing lamp. Manage in accord with
Disposal Laws. See: www.lamprecycle.org
Options:
Add appropriate
suffix to catalog
no., ie: (GLR)
HP90
Direct/Indirect
Recessed
S
Body Style:
S = Static
1
Fixture
Width
G
Ceiling Type:
Fits both
Standard Grid
and
Slot Grid
L
Acrylic Lens
28
Lamp:
(By Others)
28=T5 28W
(Nominal 48")
R
Reflector:
Specular
Aluminum
Lamp
Quantity
1=1 Lamp
2=2 Lamp
Ballast Type:
<20THD <10THD
1 or 2 Lamp Elec. T5 P
I
(28 Watt)
1 or 2 Lamp Elec. T5 PG ††
(28 Watt)
†Instant Start (120, 277 or UNV)
††Program Rapid Start (UNV only)
0.0 45.0 90.0 FLUX
0 1661 1661 1661
5 1643 1659 1678 158
15 1581 1654 1725 468
25 1466 1621 1692 737
35 1303 1470 1512 902
45 1088 1217 1236 922
55 823 913 889 793
65 537 590 558 569
75 256 283 250 291
85 38 42 38 50
90 343
Model No. H9S1GLR128UNVPG
LER = FP - 72.6 IW - 31.83 BF - 1.0
Comparative yearly lighting energy cost per
1000 lumens = $3.30
Report Number: G2006146
Catalog Number: H9S1GLR128UNVPG
Lamps: F28T5
Luminaire: HP90 1' x 4' with linear
prismatic lens.
Ballast: QTP 2x28 T5-UNV-PSN
Report is based on 2750 Lumens per lamp.
Efficiency: 84.2%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.3 1.3
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 46.760 11.760
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 4245. 4748. 4822.
55 3958. 4391. 4276.
65 3505. 3851. 3542.
75 2729. 3046. 2665.
85 1203. 1329. 1203.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01979389878582848280
02898175777268747067
03817264686257656056
04746356605449585348
05685749544742524642
06635143494237474137
07584638443733433732
08544235403429393329
09513931373126363026
10 47 36 29 34 28 24 33 28 24
ZONE LUMENS % LAMP % FIXT
00-030 1364 24.8 27.9
00-040 2266 41.2 46.3
00-060 3981 72.4 81.4
00-090 4891 88.9 100.0
90-180 0000 0.0 000.0
00-180 4891 88.9 100.0
ZONAL LUMEN SUMMARY
Model No. H9S1GLR228UNVPG
LER = FP - 77.2 IW - 63.31 BF - 1.0
Comparative yearly lighting energy cost per
1000 lumens = $3.11
Report Number: G2006140
Catalog Number: H9S1GLR228UNVPG
Lamps: F28T5
Luminaire: HP90 1' x 4' with linear
prismatic lens.
Ballast: QTP2X28T5/UNV
Report is based on 2750 Lumens per lamp.
Efficiency: 88.9%
CIE Type-Direct-Indirect
Plane: 0-Deg 90-Deg
Spacing Criteria: 1.2 1.4
Shielding Angles: 90 90
Plane: 0-Deg 90-Deg
Luminous Length: 47.760 11.760
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2006 a Genlyte company Section 5/Folio M32-20
Voltage:
120, 277 or
UNV=120-277
H9
Standard HP90
HY
For NYC Code – I.B.E.W. Manufactured
HN
For NYC Code – Local 3 Manufactured
0.0 45.0 90.0 FLUX
0 832 832 832
5 821 841 860 81
15 796 862 879 240
25 752 797 798 364
35 690 680 653 423
45 597 528 560 425
55 441 406 420 366
65 261 263 266 261
75 117 127 124 134
85 17 18 18 22
90 222
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG. 0-DEG. 45-DEG. 90-DEG.
45 2329. 2060. 2185.
55 2121. 1953. 2020.
65 1794. 1717. 1736.
75 1247. 1354. 1322.
85 538. 570. 570.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE
FLOOR CAVITY REFLECTANCE 0.20
0
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
01928885838078807876
02847772736965706763
03776862645955625854
04706153575247555046
05655447524541504540
066-4942474036454035
07564437423632413632
08524134393328383228
09483730363026352926
10 45 34 28 33 27 23 32 27 23
ZONE LUMENS % LAMP % FIXT
00-030 685 24.9 29.6
00-040 1108 40.3 47.8
00-060 1899 69.1 82.0
00-090 2316 84.2 100.0
90-180 0000 0.0 000.0
00-180 2316 84.2 100.0
ZONAL LUMEN SUMMARY