Lightolier GSW SERIES Indoor Furnishings User Manual


 
Guardsman Vandal Resistant GSW SERIES
Page 1 of 2 Ceiling or Wall Mounted Fluorescent
6" Width, 3-7/8" Deep, 24" or 48" Nominal Length, 1 or 2 Lamp T8
Lightolier a Genlyte Thomas Company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
Copyright 2003 Lightolier Section 6A/Folio P10-62
Job Inform ation Type:
Photometry Model No. GSW4232120SO
coefficients of utilization — zonal cavity method
RF 20 20 20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1817673 676562 626058
2736661 585451 545148
3665851 514642 474340
4615144 464036 423834
5564639 413531 383329
6514134 373127 342926
7483730 332824 312623
8443427 312521 292420
9413125 282319 262218
10 39 29 23 26 21 17 24 20 17
visual comfort probability
room size ceiling height ceiling height
W L 8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0
20 20 40 47 58 69 30 39 53 66
20 30 35 40 46 56 20 27 35 48
20 40 33 36 41 47 15 20 26 35
20 60 32 35 38 42 11 15 19 25
30 20 38 45 55 66 32 40 51 64
30 30 32 37 43 52 22 27 35 46
30 40 30 33 38 43 16 20 26 33
30 60 29 32 34 39 12 15 19 25
30 80 29 31 33 37 10 12 15 20
40 20 38 45 53 64 34 42 52 63
40 30 31 36 42 51 24 29 36 46
40 40 29 32 36 42 18 22 26 33
40 60 27 30 32 37 13 16 19 25
40 80 27 30 31 35 10 13 15 20
40 100 27 30 31 34 9 11 13 16
60 30 31 36 41 49 25 31 37 47
60 40 28 31 35 41 19 23 27 34
60 60 26 29 31 36 14 17 20 25
60 80 25 28 29 33 11 14 16 20
60 100 25 27 29 32 9 11 13 17
100 40 29 31 34 40 23 27 30 37
100 60 25 28 30 34 16 20 22 27
100 80 24 26 28 32 13 16 18 22
100 100 23 26 27 30 11 13 15 18
room cavity ratio
luminaries lengthwise
luminaries crosswise
Ordering Information
Explanation of Catalog Number. Example: GSW4232120SOEM
Options & Accessories
In-Line Fusing: Internal fast-blow fusing. Suffix: GLR.
Internal slow-blow fusing. Suffix: GMF.
Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz. One per fixture
standard. Suffix: R. One per ballast. Suffix: B.
Emergency Power Pack: Factory installed emergency power pack includes
charger and inverter concealed in fixture channel. Upon loss of AC power, oper-
ates one lamp at reduced light. Suffix: EM.
Stem and Canopy Sets: Suspends fixture 6", 12", 18" or 24" from surface.
Catalog Number: ASC6 CSP (6")
ASC12 CSP (12")
ASC18 CSP (18")
ASC24 CSP (24")
Specifications
Materials: Chassis parts are die-formed 20 gauge cold rolled steel.
Refractor–one-piece 50% DR virgin acrylic. End Caps–18 gauge cold rolled
steel.
Specifications (continued)
Finish: Chassis exterior–post painted white baked acrylic enamel. End Caps
and Cover–Post painted baked white enamel. Phosphate undercoating.
Refractor: Low brightness linear prismatic lens, 50% DR (impact resistant) and
50% standard acrylic, 1/8" thickness, withstands 70 ft lbs impact.
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and ULc listed.
GSW
GSW:
Guardsman
Surface/Wall
Vandal Resistant
Fluorescent
Lamp:
(By Others)
17 = T8 2' Length
32 = T8 4' Length
Lamp Quantity:
1 or 2 Lamps
Fixture
Length:
2 = 24"
4 = 48"
Voltage:
120 or 277
Ballast Type:
<20THD<10THD
1-2 Lamp Elec. T8 SO* H
I*
0° Starting T8 SD*
LOL Dimming T8 PS*
*Instant Start Standard
Other dimming options, consult factory.
Options:
Add appropriate
suffix to catalog
no, ie: (EM)
LER = FP - 62.9 IW - 59.1 BF - 0.88
Comparative yearly lighting energy cost per 1000 lumens = $4.06
G97001
GSW4232120SO
ADVANCE RIC2S32TP SOLID STATE
OCTRON BALLAST
THIS REPORT IS BASED ON PUBLISHED INDUSTRY PROCEDURES • FIELD PERFORMANCE MAY VARY FROM LABORATORY PERFORMANCE.