Lightolier FP21LEC Indoor Furnishings User Manual


 
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group •0308
Brisa
Linear Planar Surface Mount FP 21LEC
Page 2 of 2 Wall/Ceiling Mounted T5 Fluorescent ADA Compliant
Lightolier is a Philips group brand
75
150
225
300
0°
30°
60°
90°
DECORATIVE LUMINAIRE DECORATIVE LUMINAIRE
CAT. # FP21U / FPA2 21W SYLVANIA T-5 LAMPS.
LUMEN RATING = 1890 LMS. BALLAST/ ADVANCE ICN-2S28
FP21U / FPA2
Candlepower Summary
Angle Along 22.5. 45 67.5 Across.
Output
Lumens
0 280 280 280 280 280
5 281 279 278 279 278 27
15 271 270 269 272 271 77
25 253 253 255 258 257 118
35 226 228 233 238 238 146
45 193 197 206 213 213 158
55 154 161 172 178 179 152
65 110 118 129 136 137 125
75 62 70 80 85 85 82
85 17 26 35 39 40 38
90 7 15 24 28 29
95 7 15 23 27 28 23
105 9 15 26 32 34 25
115 10 14 24 32 35 23
125 9 14 21 29 32 19
135 8 12 17 23 26 13
145 7 9 14 17 18 8
155 6 7 9 12 13 4
165 6 5 6 7 9 2
175 7 7 6 5 4 1
180 6 6 6 6 6
Certified Test Report no.3651FR
Computed by LSI Program **TEST-LITE**
SC(ALONG) = 1.3, SC(ACROSS) = 1.4
Prepared For:
Lightolier
Fall River, MA
TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE
TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.
Zonal Lumens and Percentages
Zone Lumens % Lamp %Luminaire
0-30
221 11.70 21.28
367 19.43 35.32
676 35.82 65.11
921 48.77 88.66
554 29.34 53.34
244 12.95 23.55
117 6.24 11.34
1039 55.01 100.00
0-40
0-60
0-90
40-90
60-90
90-180
0-180
** Efciency = 55.0% **
Coefficients of Utilization
Ceiling 80% 70% 50% 30% 10%
Wall 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
0 .64 .64 .64 . 64 .62 .62 .62 . 62 .58 .58 . 58 .54 .54 . 54 .50 .50 .50 .49
1 .58 .56 .53 .51 .56 .54 .52 .50 .50 .49 .47 .47 .46 .44 .44 .43 .42 .40
2 .53 .48 .45 .41 .51 .47 .43 .40 .44 .41 .39 .41 .39 .37 .39 .37 .35 .34
3 .48 .42 .38 .35 .46 .41 .37 .34 .39 .35 .32 .36 .34 .31 .34 .32 .30 .28
4 .44 .38 .33 .29 .42 .36 .32 .29 .34 .30 .28 .32 .29 .26 .30 .28 .25 .24
5 .40 .33 .28 .24 .38 .32 .27 .24 .30 .26 .23 .28 .25 .22 .27 .24 .21 .20
6 .37 .29 .25 .21 .35 .29 .24 .21 .27 .23 .20 .25 .22 .19 .24 .21 .19 .17
7 .34 .26 .22 .18 .33 .26 .21 .18 .24 .20 .17 .23 .19 .17 .22 .19 .16 .15
8 .31 .24 .19 .16 .30 .23 .18 .15 .22 .18 .15 .21 .17 .14 .19 .16 .14 .13
9 .29 .21 .17 .13 .28 .21 .16 .13 .19 .16 .13 .18 .15 .12 .18 .14 .12 .11
10 .27 .19 .15 .12 .26 .19 .15 .12 .18 .14 .11 .17 .13 .11 .16 .13 .11 .10
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 25.0