Lightolier EC1-11 Indoor Furnishings User Manual


 
Job Information Type:
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group •
Lighting Systems EC1-11
Page 3 of 3 Energos Control System 1-Light T5 per 4' (121.92cm) (Nominal) Lens
C0808
Lamp Ordering Information
Design Lamp Type Wattage
Rated Output
(Lumens)
Color (K)
M T5 28 2600* 3000
N T5 28 2600* 3500
O T5 28 2600* 4100
P T5 54 4450* 3000
Q T5 54 4450* 3500
R T5 54 4450* 4100
Ballast Ordering Information
Design Lamp Type Ballast Factor Start Type THD %
F T5 1.00 Program <10
G T5HO 1.00 Program <10
I Dim T5 1.00 / .01 Program <10
J Dim T5HO 1.00 / .03 Program <10
Lamp and Ballast System Data
Design
Lamp Type
(T8 or T5)
Ballast
Factor (BF)
Ballast
THD (%)
Lamp Rated
Wattage
Lamp
Rated
Output
Lamp
Color
(Kelvin)
IES Output
(lumens)
System
Input
Watts
System
Efficacy
(lum/watt)
System
Lamp Life
(Hours)
Start
Type
FM T5 1 <10 28 2600 3000 2600 31.0 83.87 20000 Program
FN T5 1 <10 28 2600 3500 2600 31.0 83.87 20000 Program
FO T5 1 <10 28 2600 4100 2600 31.0 83.87 20000 Program
GP HO 1 <10 54 4450 3000 4450 58.5 76.07 20000 Program
GQ HO 1 <10 54 4450 3500 4450 58.5 76.07 20000 Program
GR HO 1 <10 54 4450 4100 4450 58.5 76.07 20000 Program
IM T5 DIM 1.0 / .01 <10 28 2600 3000 2600 / 26 33.5 / 8 77.60 NA Program
IN T5 DIM 1.0 / .01 <10 28 2600 3500 2600 / 26 33.5 / 8 77.60 NA Program
IO T5 DIM 1.0 / .01 <10 28 2600 4100 2600 / 26 33.5 / 8 77.60 NA Program
JP T5HO DIM 1.0 / .03 <10 54 4450 3000 4450 / 134 63 / 12.5 70.60 NA Program
JQ T5HO DIM 1.0 / .03 <10 54 4450 3500 4450 / 134 63 / 12.5 70.60 NA Program
JR T5HO DIM 1.0 / .03 <10 54 4450 4100 4450 / 134 63 / 12.5 70.60 NA Program
*25°C Rating
Do not alter lumen values or ballast factor light losses when completing
calculations using Energos IES files. Files have already been adjusted. The lumen
value for the lamp (within a Lighting Design program) will be the IES Ouput value
shown on this table.
*25°C Rating
All data is per 1 lamp on a two lamp system at 277 VAC.
Data is based on Osram Sylvania specifications.
When ordering no lamps provided by Lightolier, use lamp code “Z”.