Lightolier DPA2G24PP332 Indoor Furnishings User Manual


 
coefficients of utilization zonal cavity method
RF 20 20 20
RC 80 50 30
RW 70 50 30 50 30 10 50 30 10
1 80 77 75 72 71 69 70 68 67
2 74 69 65 65 63 60 63 61 59
3 68 62 57 59 55 52 57 54 51
4 63 56 51 53 49 46 52 48 45
5 58 50 45 48 44 40 47 43 40
6 54 46 40 44 39 36 43 38 35
7 50 42 36 40 35 32 39 35 31
8 47 38 33 37 32 28 36 31 28
9 44 35 30 34 29 26 33 29 26
10 41 32 27 31 27 23 31 26 23
visual comfort probability (VCP) average 100 fc; reflectances 80/50/20
room size ceiling height ceiling height
WL8.5 10.0 13.0 16.0 8.5 10.0 13.0 16.0
20 20 83 79 70 74 83 79 75 77
20 30 81 79 77 71 84 80 78 71
20 40 81 80 77 74 84 80 79 75
20 60 82 80 77 74 84 80 79 75
30 20 81 82 74 75 84 81 77 76
30 30 82 82 78 72 84 82 80 71
30 40 82 82 78 74 84 82 80 75
30 60 82 83 78 73 84 82 80 75
30 80 82 83 78 73 84 82 80 75
40 20 81 82 76 77 84 81 79 78
40 30 82 82 79 74 84 82 81 73
40 40 82 83 79 74 84 82 81 76
40 60 82 83 79 75 84 82 82 76
40 80 82 83 79 75 84 82 82 76
40 100 82 83 80 75 84 82 82 76
60 30 82 83 79 76 84 82 81 73
60 40 82 83 79 76 84 82 82 76
60 60 82 83 79 76 84 82 82 76
60 80 82 83 80 76 84 82 82 76
60 100 82 83 80 76 84 82 82 76
100 40 82 83 79 76 84 82 82 76
100 60 82 83 80 76 84 82 82 76
100 80 82 83 80 77 84 82 81 76
100 100 82 83 80 77 85 82 81 76
Deepcel Plus VDT DPA2G24PP332
Page 2 of 2 2' x 4' Recessed Fluorescent, 3", 24 Cell Specular Parabolic Louver
Static or Air/Return, 3 Lamp, T8 or T5
Lightolier a Genlyte company www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2007 a Genlyte company
Section 2/Folio G51-48 Rev. A
Job Information Type:
Options/Accessories
Plaster Frame: Catalog Number: PF24.
Continuous Row Installation: For F type fixtures, half width flanges are required between
fixtures. Order Catalog Number: 2FC TRIM CSP (each joint).
Radio Interference Filter:
To order one RIF per fixture; SUFFIX: R. To order one RIF per ballast;
SUFFIX: B.
Electrical Wiring Options: Consult factory.
Air Closure Strip:
SUFFIX: ACS4 (factory installed).
Drywall Kit: Order Catalog Number: FK92X4. (Request Folio OA30-10 Rev. A).
Chicago Plenum: SUFFIX: CP.
Specifications
Performance: In an installation of 3 lamp 32W luminaires in a room cavity ratio of 1,
reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .77. To prevent
glare the VCP shall be not less than 82 either lengthwise or crosswise (at 100fc level) and
the average brightness at 65° shall not exceed 850, 57 and 56 candelas per square meter
respectively in the O°, 45°, and 90° horizontal planes.
Air Handling (DPA only) side air passages for air supply or air return. Supply air is discharged
vertically. Optional side closure strips. Air return is also provided through the lamp compartment
through fixture body ends.
Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing
is ribbed for
rigidity with side rails hemmed over and housing ends turned-in for safe handling.
Louver is
pre-anodized aluminum (Coilzak
®
or equal.
Specifications (continued)
Finish: Chassis exterior–black baked polyester enamel. Cavity–white baked polyester
enamel minimum 86% reflectance. Phosphate undercoating. Louver–low iridescence semi-
specular anodized vertical grain aliminum reflector sheet is standard.
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If K.O. is with-
in 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W. UL and ULc Listed.
Photometry Model No. DPA2G24PP332120O3
LER = FP - 59.8 IW - 90.4 BF - 0.89
Comparative yearly lighting energy cost per 1000 lumens = $4.01
THISREPORTISBASEDONPUBLISHEDINDUSTRYPROCEDURES•FIELDPERFORMANCEMAYVARYFROMLABORATORYPERFORMANCE.
Deepcel Plus
Parabolic:
Pre-anodized
aluminum
louver
Body Style:
A=Air Supply
S=Static
2
Fixture
Width
3
Lamp
Quantity
Options:
Add appropriate
suffix to catalog no.,
ie: (CP)
Ordering Information
Explanation of Catalog Number. Example: DPA2G24PP332120O3CP
Ceiling Type:
G= Grid
(lay-in T bar)
F= Flanged (over
lap) Z spline and
plaster frame
T= Slot grid or
two-directional
concealed T
(see options)
24
Number of
Cells:
24=3 rows
of 8
Louver Finish:
L = Low
iridescence
Semi-specular
(standard)
P =Low
iridescence
Specular
W =White Baked
Enamel
P
Dual "V"
Reflectors
room cavity ratio
luminaries lengthwise
luminaries crosswise
Voltage:
120, 277 or
UNV=120-277
G00065
DPA2G24PP332120
3 TL80 F32T8 /TL841. EACHRATED: 2850LUMENS
2X4 TROFFERWITH 3X824CELL SPECULARLOUVER
Ballast Type:
<20THD <10THD
1 & 2 Lamp Elec. T8 SO * H
I *
1-3 Lamp Elec. T8 O3 * H3 *
1 & 2 Lamp 28W Elec. T5 P
I
1 & 2 Lamp 28W Elec. T5 PG ††
1-3 Lamp 54W Elec. T5 P5 ††
LOL T8 Dimming PS
Other dimming options. Consult factory.
*Instant Start Standard
†Instant Start (120, 277 or UNV)
††Program Rapid Start (UNV only)
NOTE:
For T8 UNV, you must use H
I
, H3 Ballast Code.
Lamp Type/
Fixture Length:
32=32W T8
28=28W T5
54=54W T5
(Nominal 48")
DP
Standard Deepcel
DY
For NYC Code I.B.E.W. Manufactured
ND
For NYC Code Local 3 Manufactured
5½" Deep Body