Architectural Decorative Vetro Downlight D02
Page 2 of 3 Compact Fluorescent
150
300
30°
60°
90°
75
225
8011CL-D4AO2
Zonal Lumens and Percentages
Zone Lumens % Lamp %Luminaire
0-30 217 18.12 46.65
0-40 319 26.60 68.52
0-60 408 34.08 87.76
0-90 465 38.83 100.00
40-90 146 12.22 31.48
60-90 57 4.75 12.24
90-180 0 .00 .00
0-180 465 38.83 100.00
** Efciency = 38.8% **
Certified test report no. 3558FR
Computed by LSI program **TEST-LITE**
SC = 1.1
Prepared For:
Lightolier
Fall River, MA
Tested According to IES Procedures. Test Distance Exceeds Five
Times the Greatest Luminous Opening of Luminaire.
Coefficients of Utilization
Ceiling 80% 70% 50% 30% 10%
Wall 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
0 .46 .46 .46 .46 .45 .45 .45 .45 .43 .43 .43 .41 .41 .41 .40 .40 .40 .39
1 .43 .42 .41 .40 .42 .41 .40 .39 .39 .39 .38 .38 .37 .37 .37 .36 .36 .35
2 .41 .38 .36 .35 .40 .38 .36 .34 .36 .35 .33 .35 .34 .33 .34 .33 .32 .31
3 .38 .35 .33 .31 .37 .34 .32 .31 .33 .32 .30 .32 .31 .30 .32 .30 .29 .28
4 .36 .32 .30 .28 .35 .32 .30 .28 .31 .29 .27 .30 .28 .27 .29 .28 .27 .26
5 .34 .30 .27 .25 .33 .29 .27 .25 .29 .27 .25 .28 .26 .25 .27 .26 .24 .24
6 .32 .28 .25 .23 .31 .27 .25 .23 .27 .24 .23 .26 .24 .23 .26 .24 .22 .22
7 .30 .26 .23 .21 .29 .25 .23 .21 .25 .22 .21 .24 .22 .21 .24 .22 .20 .20
8 .28 .24 .21 .19 .28 .23 .21 .19 .23 .21 .19 .23 .21 .19 .22 .20 .19 .18
9 .26 .22 .19 .18 .26 .22 .19 .18 .21 .19 .17 .21 .19 .17 .21 .19 .17 .17
10 .25 .21 .18 .16 .24 .20 .18 .16 .20 .18 .16 .20 .17 .16 .19 .17 .16 .15
Determined in Accordance with Current IES Published Procedures
Luminaire Input Watts = 23.0
Calculite 4” Dia. Vetro Downlight, Cat.# 8011CL/D4A02
18W G.E. Biax T/E Triple Tube. Lumen Rating = 1200 LMS.
Universal Ballast #C218UNVBES
Candlepower Summary
Angle Mean CP Lumens
0 271
5 275 26
10 287
15 285 80
20 272
25 242 111
30 203
35 161 102
40 124
45 63 57
50 43
55 37 33
60 32
65 27 27
70 22
75 18 19
80 14
85 10 11
90 7
300
600
30°
60°
90°
150
450
Luminance Summary - CD. / SQ. M.
Angle Mean CD/SQ M
45 16270
55 8129
65 6536
75 5836
85 6821
Calculite 6" Recessed Vetro Downlight, Cat.# 8021CL/D6A02
32W G.E. Biax T/E Triple Tube (Lower Position).
Lumen Rating = 2200 LMS. Universal Ballast #C2642UNVBES
Candlepower Summary
Angle Mean CP LMS. Angle Mean CP LMS.
0 523 90 6
5 525 51 95 4 4
10 576 100 2
15 598 167 105 2 2
20 578 110 2
25 525 241 115 2 2
30 452 120 2
35 367 231 125 2 2
40 284 130 2
45 209 161 135 2 2
50 130 140 2
55 85 82 145 2 1
60 65 150 2
65 50 50 155 2 1
70 38 160 2
75 27 29 165 2 1
80 19 170 2
85 11 13 175 2 0
90 6 180 3
Zonal Lumens and Percentages
Zone Lumens % Lamp %Luminaire
0-30 458 20.84 44.11
0-40 689 31.34 66.32
0-60 932 42.39 89.69
0-90 1024 46.59 98.57
40-90 335 15.24 32.25
60-90 92 4.20 8.89
90-180 14 .67 1.43
0-180 1039 47.26 100.00
** Efciency = 47.3% **
Coefficients of Utilization
Ceiling 80% 70% 50% 30% 10%
Wall 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
0 .56 .56 .56 .56 .55 .55 .55 .55 .52 .52 .52 .50 .50 .50 .48 .48 .48 .47
1 .53 .51 .50 .48 .52 .50 .49 .47 .48 .47 .46 .46 .45 .44 .44 .44 .43 .42
2 .49 .47 .45 .42 .48 .46 .44 .42 .44 .42 .41 .43 .41 .40 .41 .40 .39 .38
3 .46 .43 .40 .38 .45 .42 .39 .37 .41 .38 .37 .39 .38 .36 .38 .37 .35 .34
4 .44 .39 .36 .34 .43 .39 .36 .34 .38 .35 .33 .37 .34 .33 .36 .34 .32 .31
5 .41 .36 .33 .31 .40 .36 .33 .30 .35 .32 .30 .34 .31 .30 .33 .31 .29 .29
6 .38 .33 .30 .28 .38 .33 .30 .28 .32 .29 .27 .31 .29 .27 .31 .28 .27 .26
7 .36 .31 .27 .25 .35 .30 .27 .25 .30 .27 .25 .29 .26 .24 .28 .26 .24 .24
8 .34 .28 .25 .23 .33 .28 .25 .23 .27 .25 .23 .27 .24 .22 .26 .24 .22 .21
9 .31 .26 .23 .21 .31 .26 .23 .21 .25 .22 .20 .25 .22 .20 .24 .22 .20 .19
10 .29 .24 .21 .19 .29 .24 .21 .19 .23 .21 .19 .23 .20 .18 .23 .20 .18 .18
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 33.0
Tested According to IES Procedures. Test Distance Exceeds Five
Times the Greatest Luminous Opening of Luminaire.
Certified test report no.
3495FR
Computed by LSI program **TEST-LITE**
SC = 1.2
Prepared For:
Lightolier
Fall River, MA
8021CL-D6AO2